Introduction and objectives. Low back pain has become one of the major public health problems worldwide. Treatment is by the use of analgesics and non-steroidal anti-inflammatory drugs, but it must be taken into account that these have side-effects. Therefore, non-pharmacological therapies may be beneficial in patients at greater risk of developing chronic pain and disability, aiming to decrease pain. The objective of this study was to assess the effect of the Interferential current in women with acute low back pain. Materials and method. The study included female patients, aged 18-35 years, who had acute low back pain. The Visual Analogue Scale (VAS) of Pain and the Oswestry Disability Index (ODI) were used for evaluation. The patients received Interferential current in the bipolar form, the parameters were base current of 2 kHz, AMF 50 Hz, which was performed for 20 minutes daily, for 3 non-consecutive days in the week, for 4 weeks, totaling 12 therapies. Results. For evaluation of pain intensity, no difference was observed in the control group with a small effect size, but the treated group had a large effect size. For the ODI, comparison within the group showed no difference for the control group, but there was a decrease in the values for the treated group. Conclusion. It was found that the Interferential current was effective in the reduction of acute low back pain and functional improvement.
Chronic pain, resulting from nerve compression, is a common clinical presentation. One means of conservative treatment is low-level laser therapy, although controversial. The aim of this study was to evaluate the effects of two doses of low-level laser, at 830 nm, on pain reduction in animals subjected to sciatica. Eighteen rats were used, divided into three groups: GS (n=6), sciatica and simulated treatment; G4J (n=6), sciatica and treatment with 4 J/cm 2 ; and G8J (n=6), sciatica and irradiation with 8 J/cm 2 . The right sciatic nerve was exposed and compressed using catgut thread. Five days of treatment were started on the third postoperative day. Pain was assessed by means of the paw elevation time during gait: before sciatica, before and after the first and second therapies, and the end of the fifth therapy. Low-level laser was effective in reducing the painful condition. Key words: pain measurement, sciatica, low level laser therapy.Laser de baixa potência, 830 nm, na redução da dor em ratos submetidos à modelo experimental de ciatalgia RESUMO A dor crônica, resultante de compressão nervosa, é uma apresentação clínica frequente. Um dos meios de tratamento conservador, é o laser de baixa potência, apesar de controvérsias. O objetivo do estudo foi avaliar os efeitos de duas doses de laser de baixa potência, 830 nm, na redução da dor em animais submetidos à ciatalgia. Foram utilizados 18 ratos, divididos em 3 grupos: GS (n=6) ciatalgia e simulado o tratamento; G4J (n=6) ciatalgia e tratado com 4 J/cm 2 , G8J (n=6) ciatalgia e irradiado com 8 J/cm 2 . O nervo isquiático direito foi exposto e realizada a compressão com fio catgut. No 3° dia pós-operatório, iniciou-se o tratamento, durante 5 dias. Verificou-se a dor, por meio do tempo de elevação da pata, na marcha: anterior à ciatalgia, pré e pós 1ª e 2ª terapias, e ao final da 5ª terapia. O laser de baixa potência foi eficaz na redução do quadro álgico. Palavras-chave: medição da dor, ciática, terapia a laser de baixa intensidade.
RESUMOA dor e o edema são sinais, entre outros, que ocorrem durante a fase inflamatória no processo de cura de tendões lesados. A terapia antiinflamatória farmacológica recebe algumas críticas, com relação a seus efeitos deletérios para o reparo. Dessa forma, ganha corpo o uso de recursos físicos para o controle do processo. O objetivo do presente estudo foi avaliar o uso do laser de baixa potência sobre a dor e edema em tendão calcâneo de ratos submetidos a trauma experimental. Foram utilizados 28 ratos Wistar, divididos em quatro grupos: GC -submetido à lesão traumática e ao tratamento placebo; G2 -submetido à lesão e irradiado com laser 2J/cm 2 ; G4 -submetido à lesão e irradiado com 4J/cm 2 ; G8 -submetido à lesão e irradiado com 8J/cm 2 . A lesão foi realizada com a queda de um peso sobre a face lateral do tendão calcâneo direito de cada animal, com energia de aproximadamente 0,40J. A dor foi avaliada pelo tempo de elevação da pata (TEP) do animal caminhando durante um minuto, sobre um cilindro metálico com 30cm de diâmetro em 3rpm; a avaliação do edema ocorreu através de paquimetria; os momentos de avaliação foram: pré-lesão, pós-lesão, pós-tratamento, duas horas, oito horas, 24 horas e 5º dia de lesão. O tratamento com laser 670nm ocorreu de forma pontual e diária. Os resultados mostraram aumentos do TEP e formação de edema em todos os grupos após a lesão; para os grupos tratados houve redução da dor e do edema, fato observado no grupo controle apenas com relação à diminuição de edema no 5º dia de placebo. Conclui-se que o tratamento com laser de baixa potência diminuiu dor e edema nos animais com trauma tendíneo, de forma dose-dependente. Palavras-chave:Tendão do calcâneo, Laser de baixa potência, avaliação da dor. ABSTRACTDuring the injured tendons healing process there is the inflammatory phase, which occurs in the presen ce, among other signs, of pain and edema. The antiinflammatory drug therapy receives some criticism, with respect to its deleterious effects for the repair, thus gain body the use of physical resources for the process control. The aim of this study was to evaluate the use of low level laser therapy on the pain and edema of the rats calcaneus tendon, subjected to experimental trauma. We used 28 rats Wistar, divided into four groups: GC -subjected to traumatic injury and the placebo treatment; G2 -subject to injury and irradiated with laser 2 J/cm 2 ; G4 -subject to injury and irradiated with 4 J/cm 2 ; G8 -submitted to injury and irradiated with 8 J/cm 2 . The lesion was performed with the fall of a weight on the side of the right calcaneus tendon of each animal, with energy of about 0.40 J. The pain was evaluated by the paw elevation time (PET) for a minute, the animal walking on a metal cylinder with 30 cm in diameter at 3 rpm; the edema evaluation occurred through caliper; moments of the evaluation were: after and before injury, before treatment, 2 hours, 8 hours, 24 hours and 5 th injury day. Treatment with laser 670 nm, was so punctual and daily. The results showed increases in PE...
O objetivo deste trabalho foi verificar as adaptações de peso e comprimento do músculo sóleo de ratos Wistar machos, além da estimativa do total de sarcômeros em série e comprimento médio dos sarcômeros, quando submetidos a um processo de remobilização em esteira. Foram utilizados 18 ratos (Wistar), divididos em três grupos: GC -músculo sóleo esquerdo (MSE) imobilizado e remobilizado solto; G10 -MSE imobilizado e remobilizado em velocidade de 10m/min; e G12 (n = 6) -MSE imobilizado e remobilizado em velocidade de 12m/min. Os resultados mostraram as seguintes variações, peso muscular: GC -22,35% (p = 0,0089), G10 -12,52% (p = 0,0623), G12 -12,07%, (p = 0,0004); comprimento muscular: GC -5,47% (p = 0,0120), G10 -3,31% (p = 0,2868), G12 0,41% (p = 0,8987); estimativa de sarcômeros em série: GC -15,42% (p = 0,0047), G10 -10,87% (p = 0,0193), G12 -4,97 (p = 0,2409); comprimento de sarcômeros GC 11,16% (p = 0,0142), G10 9,31% (p = 0,1270), G12 5,58% (p = 0,1327). Conclui-se que G12 obteve maior eficácia após o período de imobilização, pois apresentou maior semelhança com o membro não imobilizado.Palavras-chave: reabilitação, músculo esquelético, sarcômeros. ABSTRACTThe aim of this work was to compare weight and length adaptations of the soleus muscle of male Wistar rats as well as estimation of the total number of serial sarcomere and mean sarcomere length, when they are submitted to remobilization on treadmill. 18 Wistar male rats were used and divided in the three following groups: CG -left soleus (LS) muscle immobilized and remobilized free in the cage; G10 -LS muscle immobilized and remobilized in speed of 10 m/min on treadmill; and G12 -LS muscle immobilized and remobilized in speed of 12 m/min. The right muscles (RS) of each animal were used for comparison. The results showed the following variations, muscular weigh: CG -22.35% (p = 0.0089), G10 -12.52% (p = 0.0623), G12 -12.07%, (p = 0.0004); muscle length: CG -5.47% (p = 0.0120), G10 -3.31% (p = 0.2868), G12 0.41% (p = 0.8987); estimation of number of serial sarcomere: CG -15.42% (p = 0.0047), G10 -10.87% (p = 0.0193), G12 -4.97 (p = 0.2409); sarcomere length: CG 11.16%, (p = 0.0142), G10 9.31% (p = 0.1270), G12 5.58% (p = 0.1327). It was concluded that G12 presented the best effectiveness after immobilization period since it presented greater similarity with the non-immobilized soleus.Keywords: rehabilitation, skeletal muscle, sarcomere. INTRODUÇÃOA literatura científica comprova que os músculos esqueléticos possuem plasticidade muscular, ou seja, respondem a diferentes estímulos impostos, dentre eles: exercícios físicos, alterações hormonais, nutrição, denervação, eletroestimulação, imobilização, dentre outros (1)(2)(3)(4) . A inatividade causa ao músculo significativo remodelamento, incluindo a perda de proteínas miofibrilares, mudanças em atividades metabólicas, alterações vasculares e neurais (5) . Contudo, a imobilização, que gera desuso, ainda é uma opção de tratamento freqüentemente usada em distúrbios musculoesqueléticos, apesar da ocorrência da atro...
RESUMO | No tratamento de lesões tendíneas, o uso do ultrassom surge como possibilidade terapêutica, apesar de lacunas sobre seus efeitos clínicos. O objetivo foi avaliar dois protocolos de ultrassom terapêutico sobre dor e edema após trauma tendíneo. Vinte e um ratos Wistar foram submetidos a trauma no tendão calcâneo e divididos em três grupos: sham (GS); ultrassom contínuo (GUC); e ultrassom pulsado (GUP). O trauma ocorreu sobre a face lateral do tendão calcâneo direito, com energia de 0,40 J. A dor foi avaliada pelo teste de incapacidade funcional e o edema, pelo diâmetro laterolateral. Foram realizadas avaliações previamente à lesão; após 1 hora da indução da lesão; após o 1º tratamento; 2, 8 e 24 horas após lesão; e após o 5º dia. O tratamento ocorreu em 5 dias, com transdutor de 1 MHz, durante 3 minutos, sobre o local do trauma, com dose de 0,4 W/cm 2 SATA. Os resultados da incapacidade funcional para GS mostraram aumento da nocicepção. Para GUC houve aumento ao comparar a avaliação 1 (AV1) com as avaliações 2 (AV2), 3 (AV3) e 4 (AV4); ao comparar AV2 com as avaliações 5 (AV5) e 6 (AV6) houve diminuição de valores. Para GUP houve aumento ao comparar AV1 com AV2 e AV3, mas ao comparar AV2 com as seguintes, houve diminuição significativa a partir de AV4. Para o edema, os grupos tratados produziram aumento inicial, com redução nas últimas avaliações. O ultrassom terapêutico produziu diminuição de dor e edema, mais precocemente para a forma pulsada.Descritores | tendão do calcâneo; ultrassom; dor; regeneração.ABSTRACT | In tendon injuries treatment, the use of ultrasound appears as a therapeutic option, despite the lack of their clinical effects. The aim was to evaluate two therapeutic ultrasound protocols, continuous or pulsed, on the pain and swelling after tendinous trauma. Twenty-one Wistar rats were subjected to traumatic injury in the tendon and divided in three groups: sham (GS), continuous ultrasound (GUC), and pulsed ultrasound (GUP). The injury occurred on right Achilles tendon lateral aspect, with energy of 0.40 J. The pain was assessed by the functional disability test and edema by latero-lateral diameter. The evaluations were performed before the injury; after 1 hour of the lesion induction; after the 1st treatment; 2, 8 and 24 hours after injury; and after the 5th day. The treatment was made for 5 consecutive days, with transductor of 1 MHz, for 3 minutes on the trauma site, with a dose of 0.4 W/cm 2 SATA. The results of functional disability for GS showed increased nociception. For GUC, there was increased when comparing evaluation 1 (EV1) with evaluations 2 (EV2), 3 (EV3) and 4 (EV4); comparing EV2 to evaluations 5 (AV5) and 6 (AV6), there was decreased values. To GUP there was increased when comparing EV1 with EV2 and EV3, but when comparing EV2 with the following, there was a significant decrease starting from EV4. Edema, treatment groups produced an initial increase with a reduction in recent evaluations. The therapeutic ultrasound produced pain and edema reduction in rats with tendon traum...
Durante o processo inflamatório, alguns tipos de células predominam e estão envolvidos com a produção de dor. O laser de baixa potência mostra-se útil no controle de mediadores inflamatórios, mas a ampla divergência nos parâmetros dosimétricos, conduz a variações nos resultados positivos. O objetivo deste estudo foi analisar o uso do laser 808nm, na dor articular crônica e edema de ratos Wistar submetidos a sinovite. Foram utilizados 10 ratos Wistar, divididos em dois grupos: GC - indução de sinovite em joelho direito e tratamento placebo; GT - indução de sinovite e irradiado com laser 10J/cm². Para a produção de sinovite foram injetados 100µl de formalina a 5%, no espaço articular tibiofemoral direito. A avaliação da dor ocorreu pelo tempo de elevação da pata (TEP). No 10º dia após a indução de sinovite, iniciou-se o tratamento com laser sobre a face articular medial do joelho, procedimento mantido no decorrer de 10 dias. Os resultados mostraram que o laser apresentou efeitos analgésicos, visto que, para o grupo tratado, houve redução significativa nos valores de TEP, indicando redução da dor, quando comparados os valores pós-tratamento com os pré-tratamento, o que não ocorreu para o grupo que recebeu tratamento placebo; para o edema, o laser também mostrou redução significativa do mesmo. Concluiu-se que o laser 808nm, com 10J/cm², é eficaz na redução da dor articular crônica e edema, em animais submetidos a sinovite experimental.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.