SummaryThis study was conducted to evaluate the clinical application of computed tomography of the canine femoral intercondylar notch. The canine femoral intercondylar notch is angled 12 degrees from the dorsal plane and obliqued 7 degrees proximolateral to distomedial in the sagittal plane. Measurements of the notch were performed with eight, 12, and 16 degrees of gantry tilt. With the exception of proximal opening notch angle, significant differences were not detected in measurements referenced to 12 degrees of gantry tilt. Evidence from this study indicated that a ± 4 degree variation in gantry tilt angle from a desired angle of 12 degrees did not significantly affect clinical interpretations of intercondylar notch measurements or notch width index ratios.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.