Nitric oxide (NO) was analysed in expired air from 27 healthy human subjects. At rest the NO concentration was 10.5 +/- 0.9 ng 1-1 (mean +/- SEM) corresponding to 8.6 +/- 0.7 parts per billion (ppb). The expired NO concentration did not change when the subjects were switched from breathing NO-free tank gas to room air which contained 7.7 ng l-1 NO. Repeated measurements of expired NO with an interval of 1 day showed a mean variation of 2.2 +/- 0.7 ng l-1 NO. The NO concentration in the first portion in the expired tidal volume (44%) was insignificantly higher than in the latter expired portion, 6.9 +/- 1.9 vs. 5.1 +/- 1.0 ng l-1 (n = 5). During moderately heavy exercise on an ergometer bicycle (90 W for women, n = 4, 150 W for men, n = 4) the expired concentration of NO decreased, however because of increased minute ventilation, the expired amount of NO almost doubled (from 111 +/- 12 to 209 +/- 30 ng min-1). The source of the expired NO is not clear and both the airways and the pulmonary circulation may contribute.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.