SummaryWe have examined the differences in ventilatory characteristics between halothane and sevoflurane when used for adult vital capacity induction of anaesthesia. The study was conducted in a randomized, double-blind manner. After 13 patients had been enrolled, the study was curtailed because the blinded observer thought that there was an unacceptably high incidence of adverse events. After the randomization code was revealed, the adverse events were found to be in the halothane group. Although the sample size was small, minute volumes appeared to be maintained in the sevoflurane group. Ventilatory frequencies were similar in the two groups after insertion of the laryngeal mask airway, but tidal volumes were significantly greater in the sevoflurane group (P:0.0013). (Br.
Recent research has shown that gaseous induction in adults with sevoflurane is an acceptable technique. This study was undertaken to assess if gaseous induction using sevoflurane carried in both oxygen alone, and in nitrous oxide and oxygen combined, would provide acceptable pollution levels. As an occupational exposure standard has not been set for sevoflurane, we used the target level of 20 ppm set by the manufacturer. Environmental monitoring was carried out in the anaesthetic room during eight lists where consecutive triple vital capacity sevoflurane inductions were performed. Time-weighted averages for both gases over the duration of the lists were well below the occupational exposure standards (mean 1.1 (range 0.6-1.7) for sevoflurane and 17.3 (12-23) for nitrous oxide). There were high peak concentrations during the induction process (8.3 (4.1-17) for sevoflurane and 172.4 (65-310) for nitrous oxide) although these decreased to low concentrations between anaesthetic inductions. Personal sampling was carried out from the anaesthetist's breathing zone and concentrations were also low (1.2 (0.8-2.1) for sevoflurane and 45.9 (10.1-261.6) for nitrous oxide.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.