Background Artificial stroke models can be used for testing various thrombectomy devices. Objective To determine the value of combined stentriever–aspiration thrombectomy compared with the stentriever-alone approach. Methods We designed an in vitro model of the intracranial circulation with a focus on the middle cerebral artery (MCA) that closely resembles the human intracranial circulation. After introducing fresh clot in the MCA, we used conventional biplane angiography and microangiographic fluoroscopy to compare recanalization rates and occurrence of emboli in new, unaffected territory for thrombectomy approaches in which a stentriever (Solitaire flow restoration stentriever, Covidien) was used alone or in combination with continuous manual aspiration through a Navien catheter (Covidien). Results In a total of 22 experiments (11 for each approach), successful clot delivery to the MCA was achieved in all cases. Successful angiographic recanalization (thrombolysis in cerebral infarction score of 2b–3) was achieved more frequently with the combined stentriever–aspiration approach than with the stentriever-alone approach (in 10 vs 4 experiments, p=0.023). Emboli in new territory occurred in three experiments with the stentriever-alone approach, and none were seen with the combined approach (p=0.21). Conclusions The combined stentriever–aspiration approach to thrombectomy leads to better angiographic recanalization rates than use of the stentriever alone. Further experiments are needed to test the value of balloon-guide catheters and aspiration performed using other types of catheters and modes of aspiration.
Application of the GCE in this experimental stroke model to retrieve typically recalcitrant fibrin rich clots resulted in higher successful recanalization rates than the SR.
Minimally invasive endovascular image-guided interventions (EIGIs) are the preferred procedures for treatment of a wide range of vascular disorders. Despite benefits including reduced trauma and recovery time, EIGIs have their own challenges. Remote catheter actuation and challenging anatomical morphology may lead to erroneous endovascular device selections, delays or even complications such as vessel injury. EIGI planning using 3D phantoms would allow interventionists to become familiarized with the patient vessel anatomy by first performing the planned treatment on a phantom under standard operating protocols. In this study the optimal workflow to obtain such phantoms from 3D data for interventionist to practice on prior to an actual procedure was investigated. Patient-specific phantoms and phantoms presenting a wide range of challenging geometries were created. Computed Tomographic Angiography (CTA) data was uploaded into a Vitrea 3D station which allows segmentation and resulting stereo-lithographic files to be exported. The files were uploaded using processing software where preloaded vessel structures were included to create a closed-flow vasculature having structural support. The final file was printed, cleaned, connected to a flow loop and placed in an angiographic room for EIGI practice. Various Circle of Willis and cardiac arterial geometries were used. The phantoms were tested for ischemic stroke treatment, distal catheter navigation, aneurysm stenting and cardiac imaging under angiographic guidance. This method should allow for adjustments to treatment plans to be made before the patient is actually in the procedure room and enabling reduced risk of peri-operative complications or delays.
BACKGROUND AND PURPOSE:A new in vitro cerebrovascular occlusion model of the intracranial circulation was developed recently for testing thrombectomy devices. Using this model, we compared recanalization success associated with different modern endovascular thrombectomy approaches.
Application of the Cover device in this experimental model resulted in higher successful recanalization rates, no embolic events, and was more effective than use of the conventional guide catheter or BGC.
3D printing an anatomically accurate, functional flow loop phantom of a patient’s cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient’s cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. Results After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.
Background Three-dimensional (3D) printing has revolutionized training, education, and device testing. Understanding the design and physical properties of 3D-printed models is important. Objective To systematically review the design, physical properties, accuracy, and experimental outcomes of 3D-printed vascular models used in neurointervention. Methods We conducted a systematic review of the literature between January 1, 2000 and September 30, 2018. Public/Publisher MEDLINE (PubMed), Web of Science, Compendex, Cochrane, and Inspec databases were searched using Medical Subject Heading terms for design and physical attributes of 3D-printed models for neurointervention. Information on design and physical properties like compliance, lubricity, flow system, accuracy, and outcome measures were collected. Results A total of 23 articles were included. Nine studies described 3D-printed models for stroke intervention. Tango Plus (Stratasys) was the most common material used to develop these models. Four studies described a population-representative geometry model. All other studies reported patient-specific vascular geometry. Eight studies reported complete reconstruction of the circle of Willis, anterior, and posterior circulation. Four studies reported a model with extracranial vasculature. One prototype study reported compliance and lubricity. Reported circulation systems included manual flushing, programmable pistons, peristaltic, and pulsatile pumps. Outcomes included thrombolysis in cerebral infarction, post-thrombectomy flow restoration, surgical performance, and qualitative feedback. Conclusion Variations exist in the material, design, and extent of reconstruction of vasculature of 3D-printed models. There is a need for objective characterization of 3D-printed vascular models. We propose the development of population representative 3D-printed models for skill improvement or device testing.
BackgroundThe amount of force applied on a device is an important measure to evaluate the endovascular and surgical device manipulations. The measure has not been evaluated for neuroenodvascular procedures.PurposeWe aimed to study the use of force measure as a novel approach to test distal access catheter (DAC) performance during catheterization of cervical and intracranial vessels using patient specific 3-dimentional (3D) phantoms.MethodsUsing patient specific 3D phantoms of the cervical and intracranial circulation, we recorded measure of force required to deliver three types of DACs beyond the ophthalmic segment of the internal carotid artery. Six different combinations of DAC–microcatheter–guidewire were tested. We intentionally included what we considered suboptimal combinations of DACs, microcatheters, and guidewires during our experiments to test the feasibility of measuring force under different conditions. A six axis force sensor was secured to the DAC with an adjustable torque used to track axially directed push and pull forces required to navigate the DAC to the target site.ResultsIn a total of 55 experiments, we found a significant difference in the amount of force used between different DACs (mean force for DAC A, 1.887±0.531N; for DAC B, 2.153±1.280 N; and for DAC C, 1.194±0.521 N, P=0.007). There was also a significant difference in force measures among the six different catheter systems (P=0.035).ConclusionsSignificant difference in the amount of force used between different DACs and catheter systems were recorded. Use of force measure in neuroendovascular procedures on 3D printed phantoms is feasible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.