This laboratory has previously reported on the development of a flow cytometry-based method for scoring in vitro micronuclei in mouse lymphoma (L5178Y) cells [Avlasevich et al., Environ. Molec. Mutagen. 47 (2006) 56-66]. With this method, necrotic and mid/late stage apoptotic cells are labeled with the fluorescent dye ethidium monoazide. Cells are then washed, stripped of their cytoplasmic membranes, and incubated with RNase plus a pan-nucleic acid dye (SYTOX Green). This process provides a suspension of free nuclei and micronuclei that are differentially stained relative to chromatin associated with dead/dying cells. The current report extends this line of investigation to include the human cell line TK6. Additionally, methods are described that facilitate simultaneous quantitative analysis of cytotoxicity, perturbations to the cell cycle, and what we hypothesize is aneuploidization. This comprehensive cytogenetic damage assay was evaluated with the following diverse agents: etoposide, ionizing radiation, methyl methanesulfonate, vinblastine, ethanol, and staurosporine. Cells were harvested after 30 hrs of continuous treatment (in the case of chemicals), or following graded doses of radiation up to 1 Gy. Key findings include the following: (1) Significant discrepancies in top dose selection were found for five of the six agents studied when relative survival measurements were based on Coulter counting versus flow cytometry. (2) Both microscopy-and flow cytometry-based scoring methods detected dose-dependent micronucleus formation for the four genotoxic agents studied, whereas no significant increases were observed for the presumed nongenotoxicants ethanol and staurosporine when top dose selection was based on flow cytometric indices of cytotoxicity. (3) SYTOX and ethidium monoazide fluorescence signals conveyed cell cycle and cell death information, respectively, and appear to represent valuable aids for interpreting micronucleus data. (4) The frequency of hypodiploid nuclei increased in response to each of the genotoxic agents studied, but not following exposure to ethanol or staurosporine. Collectively, these results indicate that a comprehensive assessment of genotoxicity and other test article-induced toxicities can be acquired simultaneously using a simple two-color flow cytometry-based technique.
The ability to effectively monitor gene mutation and micronucleated reticulocyte (MN-RET) frequency in short-term and repeated dosing schedules was investigated using the recently developed flow cytometric Pig-a mutation assay and flow cytometric micronucleus analysis. Eight reference genotoxicants and three presumed nongenotoxic compounds were studied: chlorambucil, melphalan, thiotepa, cyclophosphamide, azathioprine, 2-acetylaminofluorene, hydroxyurea, methyl methanesulfonate, o-anthranilic acid, sulfisoxazole, and sodium chloride. These experiments extend previously published results with seven other chemicals. Male Sprague Dawley rats were treated via gavage for 3 or 28 consecutive days with several dose levels of each chemical up to the maximum tolerated dose. Blood samples were collected at several time points up to day 45 and were analyzed for Pig-a mutation with a dual-labeling method that facilitates mutant cell frequency measurements in both total erythrocytes and the reticulocyte subpopulation. An immunomagnetic separation technique was used to increase the efficiency of scoring mutant cells. Blood samples collected on day 4, and day 29 for the 28-day study, were evaluated for MN-RET frequency. The three nongenotoxicants did not induce Pig-a or MN-RET responses. All genotoxicants except hydroxyurea increased the frequency of Pig-a mutant reticulocytes and erythrocytes. Significant increases in MN-RET frequency were observed for each of the genotoxicants at both time points. Whereas the highest Pig-a responses tended to occur in the 28-day studies, when total dose was greatest, the highest induction of MN-RET was observed in the 3-day studies, when dose per day was greatest. There was no clear relationship between the maximal Pig-a response of a given chemical and its corresponding maximal MN-RET response, despite the fact that both endpoints were determined in the same cell lineage. Taken with other previously published results, these data demonstrate the value of integrating Pig-a and micronucleus endpoints into in vivo toxicology studies, thereby providing information about mutagenesis and chromosomal damage in the same animals from which toxicity, toxicokinetics, and metabolism data are obtained.
In vivo mutation assays based on the Pig-a null phenotype, that is, the absence of cell surface glycosylphosphatidylinositol (GPI) anchored proteins such as CD59, have been described. This work has been accomplished with hematopoietic cells, most often rat peripheral blood erythrocytes (RBCs) and reticulocytes (RETs). The current report describes new sample processing procedures that dramatically increase the rate at which cells can be evaluated for GPI anchor deficiency. This new method was applied to blood specimens from vehicle, 1,3-propane sultone, melphalan, and N-ethyl-N-nitrosourea treated Sprague Dawley rats. Leukocyte- and platelet- depleted blood samples were incubated with anti-CD59-phycoerythrin (PE) and anti-CD61-PE, and then mixed with anti-PE paramagnetic particles and Counting Beads (i.e., fluorescent microspheres). An aliquot of each specimen was stained with SYTO 13 and flow cytometric analysis was performed to determine RET percentage, RET:Counting Bead ratio, and RBC:Counting Bead ratio. The major portion of these specimens were passed through ferromagnetic columns that were suspended in a magnetic field, thereby depleting each specimen of wild-type RBCs (and platelets) based on their association with anti-PE paramagnetic particles. The eluates were concentrated via centrifugation and the resulting suspensions were stained with SYTO 13 and analyzed on the flow cytometer to determine mutant phenotype RET:Counting Bead and mutant phenotype RBC:Counting Bead ratios. The ratios obtained from pre- and post-column analyses were used to derive mutant phenotype RET and mutant phenotype RBC frequencies. Results from vehicle control and genotoxicant-treated rats are presented that indicate the scoring system is capable of returning reliable mutant phenotype cell frequencies. Using this wild-type cell depletion strategy, it was possible to interrogate ≥ 3 million RETs and ≥ 100 million RBCs per rat in approximately 7 minutes. Beyond considerably enhancing the throughput capacity of the analytical platform, these blood-processing procedures were also shown to enhance the precision of the measurements.
The in vitro micronucleus test has received considerable attention in recent years for its use in drug safety assessment and toxicological research. The less tedious nature of the assay relative to chromosome aberration analyses is a driving force, and explains why many chemical and drug safety programs have adopted the endpoint. Development of a high-throughput micronucleus scoring system would further enhance the utility of the assay for lead optimization and other early drug development work. Although several variations of a flow cytometric (FCM) method for scoring cell-culture-derived micronuclei (MN) have been described in the literature, they have been unable to distinguish true MN from apoptotic and necrotic chromatin (Nüsse M and Marx K 1997: Mutat Res 392: 109-115). Here, we report advances to this methodology whereby a sequential staining procedure is used to differentially label these types of sub-2n particles. With the use of ethidium monoazide (EMA), the chromatin of dead and dying cells is labeled. After a photoactivation step that covalently binds EMA to chromatin, cytoplasmic membranes are digested and resulting lysates are incubated with RNase plus a pan-nucleic acid dye (SYTOX Green). This process provides a suspension of free nuclei and sub-2n particles that are labeled with either SYTOX or SYTOX and EMA. Preliminary studies with heat-shocked L5178Y mouse cells demonstrated that EMA stains necrotic and mid- through late-stage apoptotic cells. Importantly, the sequential labeling procedure provided reliable micronucleus enumeration, even when cultures contained high percentages of dead cells. Subsequently, experiments with the following diverse genotoxicants were performed: hydroxyurea, methyl methanesulfonate, benzo[a]pyrene, etoposide, cyclophosphamide, and vinblastine. Additionally, the nongenotoxicants sucrose, tributyltin methoxide, and dexamethasone were tested up to 5 mg/ml, or to cytotoxic concentrations. FCM data were found to correspond closely with microscopy-based measurements. Collectively, these data suggest that this sequential EMA/SYTOX staining procedure provides reliable, high-throughput enumeration of in vitro MN.
An in vivo mutation assay has been developed based on flow cytometric enumeration of glycosylphosphatidylinositol (GPI) anchor-deficient rat erythrocytes. With this method, blood is incubated with anti-CD59-PE and SYTO 13 dye, and flow cytometry is used to score the frequency of CD59-negative erythrocytes. The experiments described herein were designed to define the kinetics of mutant erythrocyte appearance and disappearance from peripheral blood to support appropriate treatment and sampling designs for the assay. Wistar Han rats were treated with one of five prototypical mutagens: N-ethyl-N-nitrosourea (ENU); 7,12-dimethyl-1,2-benz[a]anthracene (DMBA); 4-nitroquinoline-1-oxide; benzo[a]pyrene; and N-methyl-N-nitrosourea. ENU and DMBA were also evaluated in Sprague Dawley rats. Animals were treated on three consecutive days (days 1-3) via oral gavage, and blood specimens were obtained on days -1, 4, 15, 30, 45, and 90 (and day 180 for ENU). A second endpoint of genotoxicity, the frequency of peripheral blood micronucleated reticulocytes, was measured on day 4. Each chemical induced micronuclei and the GPI anchor-deficient phenotype. Increased mutant cell frequencies were evident at day 15. Mutant reticulocyte frequencies remained relatively stable for some chemicals, but others peaked and then dropped significantly. The differences in kinetics observed are presumably related to the degree to which mutation occurs in hematopoietic stem cells versus more committed cells with limited self-renewal capacity. Collectively, the results suggest that enumerating GPI anchor-deficient erythrocytes is an efficient means of evaluating the in vivo mutagenic potential of chemicals. The kinetics and ease of scoring this blood-based endpoint suggest that integration into routine toxicology studies will be feasible.
Two endpoints of genetic toxicity, mutation at the X-linked Pig-a gene and chromosomal damage in the form of micronucleated reticulocytes (MN-RETs), were evaluated in blood samples obtained from 28-day repeat-dosing studies typical of those employed in toxicity evaluations. Male Wistar Han rats were treated at 24-h intervals on days 1 through 28 with one of five prototypical genotoxicants: N-ethyl-N-nitrosourea, 7,12-dimethyl-12-benz[a]anthracene, 4-nitroquinoline-1-oxide (4NQO), benzo(a)pyrene, and N-methyl-N-nitrosourea. Flow cytometric scoring of CD59-negative erythrocytes (indicative of glycosylphosphatidylinositol anchor deficiency and hence Pig-a mutation) was performed using blood specimens obtained on days -1, 15, 29, and 56. Blood specimens collected on days 4 and 29 were evaluated for MN-RET frequency using flow cytometry-based MicroFlow Kits. With the exception of 4NQO, each chemical induced significant increases in the frequency of MN-RETs on days 4 and 29. All five agents increased the frequency of mutant phenotype (CD59 negative) reticulocytes (RETs) and erythrocytes. Mutation responses in RETs occurred earlier than in erythrocytes and tended to peak, or nearly peak, at day 29. In contrast, the mutant phenotype erythrocyte responses were modest on day 29 and required additional time to reach their maximal value. The observed kinetics were expected based on the known turnover of RETs and erythrocytes. The data show that RETs can serve as an appropriate indicator cell population for 28-day studies. Collectively, these data suggest that blood-based genotoxicity endpoints can be effectively incorporated into routine toxicology studies, a strategy that would reduce animal usage while providing valuable genetic toxicity information within the context of other toxicological endpoints.
Experiments described herein were designed to evaluate the performance characteristics of a flow cytometry-based system that scores the incidence of peripheral blood micronucleated reticulocytes (MN-RETs). These procedures represent the continued refinement of a previously reported anti-CD71-based method (Dertinger et al. [1996]: Mutat Res 371:283-292), with the following modifications: incorporation of a third fluorescent label to exclude platelets from the MN-RET region, and use of a CD71-associated fluorescence thresholding technique to increase data acquisition rates. Mouse, rat, and human blood samples were analyzed using both the previously described two-color procedure (anti-CD71-FITC and propidium iodide) and a newly developed three-color technique (which adds an antiplatelet-PE antibody). The rodent specimens were also evaluated by standard microscopy procedures (acridine orange staining). Mouse blood was collected via heart puncture of vehicle- and 5-fluorouracil-treated CD-1 mice; blood samples from saline-treated Sprague-Dawley rats were collected from the tail vein and via heart puncture. Rodent blood samples were analyzed by both the two- and three-color methods. Human blood specimens, obtained via arm venipuncture from cancer patients undergoing radiation therapy, were analyzed for MN-RETs using the two-color method. Subsequently, blood samples from a single chemotherapy patient were analyzed by both the two- and three-color methods. Finally, the chemotherapy patient blood samples and blood samples from 15 healthy volunteers were evaluated at very high densities in conjunction with a CD71-associated fluorescence thresholding technique. Results of these investigations showed that data from mouse blood analyzed by the two- and three-color procedures correlated well with microscopy data (r values = 0.917 and 0.937 for the two- and three-color methods, respectively); all three methods confirmed the genotoxicity of 5-FU. Data from rat tail vein samples showed improved reproducibility with the three-color technique, but no significant difference between the two techniques was seen with the heart puncture specimens. Human blood analyzed according to the two-color procedure produced unreliable results, as platelets and platelet aggregates impacted the rare MN-RET scoring region. The three-color technique effectively overcame this problem and produced reproducible measurements that fell within expected ranges. For human blood analyses, the high cell density/CD71-thresholding technique provided significant improvements over the low-density technique, as it allowed data acquisition to occur approximately six times faster with no loss of sensitivity.
An international, multi-lab trial was conducted to evaluate a flow cytometry-based method for scoring micronuclei in mouse lymphoma L5178Y cells [Avlasevich et al., Environ. Molec. Mutagen. 47 (2006) [56][57][58][59][60][61][62][63][64][65][66]. A reference laboratory investigated the potential of six chemicals to induce micronuclei-the genotoxicants mitomycin C, etoposide, and vinblastine, and the non-genotoxicants sucrose, staurosporine, or dexamethasone. The latter two non-genotoxicants were selected as extreme challenges to the assay because of their potent apoptogenic activity. Three collaborating laboratories were supplied with prototype In Vitro MicroFlow ™ kits, and each was assigned one genotoxicant and one non-genotoxicant. Cells were treated continuously for 24 hrs over a range of concentrations up to 5 mg/ml, or overtly cytotoxic concentrations. Micronuclei were scored via standard microscopy and flow cytometry. In addition to enumerating micronucleus frequencies, a cytotoxicity measurement that is simultaneously acquired with the flow cytometric micronucleus scoring procedure was evaluated (Flow-NBR). With this method, latex particles served as counting beads, and facilitated relative survival measurements that exclude the presence of dead/dying cells. For comparison purposes, additional cytotoxicity endpoints were measured, including several that are based on cell number, and others that reflect compromised membrane integrity, including dye permeability and/or phospholipid distribution. Key findings for this set of compounds include the following: (1) significant discrepancies in top concentration selection were found when cytotoxicity measurements were based on different methods, with the Flow-NBR approach tending to be the most sensitive, (2) both microscopy-and flow cytometry-based scoring methods detected concentrationdependent micronucleus formation for the three genotoxic agents studied, with good agreement between the reference laboratory and the collaborating laboratories, and (3) whereas flow cytometric analyses showed no significant increases for the non-genotoxicants when top concentration selection was based on Flow-NBR, significantly elevated micronucleus frequencies were observed for concentrations that were chosen based on less-sensitive cytotoxicity assays. Collectively, these results indicate that rapid assessment of genotoxicity can be accomplished with a relatively simple Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. NIH Public Access
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.