PurposeTo evaluate the efficacy of the virtual reality training simulator Eyesi to prepare surgeons for performing pars plana vitrectomies and its potential to predict the surgeons’ performance.MethodsIn a preparation phase, four participating vitreoretinal surgeons performed repeated simulator training with predefined tasks. If a surgeon was assigned to perform a vitrectomy for the management of complex retinal detachment after a surgical break of at least 60 hours it was randomly decided whether a warmup training on the simulator was required (n = 9) or not (n = 12). Performance at the simulator was measured using the built-in scoring metrics. The surgical performance was determined by two blinded observers who analyzed the video-recorded interventions. One of them repeated the analysis to check for intra-observer consistency. The surgical performance of the interventions with and without simulator training was compared. In addition, for the surgeries with simulator training, the simulator performance was compared to the performance in the operating room.ResultsComparing each surgeon’s performance with and without warmup trainingshowed a significant effect of warmup training onto the final outcome in the operating room. For the surgeries that were preceeded by the warmup procedure, the performance at the simulator was compared with the operating room performance. We found that there is a significant relation. The governing factor of low scores in the simulator were iatrogenic retinal holes, bleedings and lens damage. Surgeons who caused minor damage in the simulation also performed well in the operating room.ConclusionsDespite the large variation of conditions, the effect of a warmup training as well as a relation between the performance at the simulator and in the operating room was found with statistical significance. Simulator training is able to serve as a warmup to increase the average performance.
The inflammatory cytokines were more often correlated with morphological changes assessed by SD-OCT, whereas VEGF-A did not correlate with CRVO-associated changes in SD-OCT. VEGF inhibition alone may not be sufficient to decrease the inflammatory response in CRVO therapy.
A novel LED-endoilluminator which can be attached to a speculum was developed. The system does not need any connection to an external light source and, consequently, also avoids usage of an optical fibre. Regular and uniform illumination of the intraocular space was achieved by transmitted and scattered visible irradiation, avoiding an incision. The duration of potential light exposure, compared to existing illumination systems, can be significantly increased. This is also true when the illuminator is not directly placed over the pars-plana and the distance to the retina is reduced. Only a part of the light reaches the retina and the fraction of short wavelength becomes very small. Increased safety of the system results from now being able to increase the exposure time and reduce phototoxic stress to the retina.
Introduction For management of complicated retinal detachments, a pars plana vitrectomy with temporary silicone oil (SO) fill is the method of choice. According to literature, the retinal redetachment rate varies between <10% and >70% with around 36% in our own group (retrospective data analysis, n = 119 eyes). Methods The main goal was to reduce the retinal redetachment rate. Standard operating procedures (SOPs) and evaluation protocols (EVALPs) were developed to prospectively analyse risk factors. Lab analysis of SO was performed, and the role of surgical experience was evaluated and investigated with Eyesi®. Results We achieved a significant reduction of the retinal redetachment rate (to 6.80%, n = 101, p = 0.002). After surgery with SO injection, neither further membrane peeling (in 16.5%) nor retinal laser coagulation (in 100%) during revision surgery had a significant effect on the reattachment rate (p = 0.167, p = 0.23), while extensive additional laser coagulation reduced visual acuity (p = 0.01). A 3-port approach had to be set up to complete SO removal. A difference in success rate depending on surgical experience was confirmed, and the performance in Eyesi correlated with that in the patients' eye. Conclusions A SOP- and EVALP-based management and new strategies to secure the surgical performance seem to be essential for successful surgery.
Introduction. To evaluate the impact of the eye lens status and oil side effects on the outcome of vitreoretinal surgery in retinal detachment with proliferative vitreoretinopathy (PVR) and a temporary silicone oil tamponade (SOT). Methods. 101 eyes were analyzed retrospectively and 103 eyes prospectively in regard to their retinal reattachment success rate and key factors for the outcome. Subgroup analysis of 27 eyes with Scheimpflug lens photography (SLP) before and after retinal reattachment service with SOT was performed. For SLP (65% phakic eyes) a Pentacam densitometry reference body with 3 mm diameter was chosen and 3 segments (anterior/mid/posterior) were evaluated separately after a quality check. Results. The retinal reattachment rate was highest in the prospective pseudophakic group (p = 0.039). Lens transparency loss occurred earlier in middle aged patients than in younger patients. Besides the nucleus, layers posterior and anterior to it showed specific transparency changes. The emulsification rate was higher when eyes had been operated on in the anterior chamber before retinal reattachment service. Conclusions. Retinal reattachment surgery seems to benefit from preoperative cataract removal. We found significant lens changes in the nucleus as well as in the layers anterior and posterior to it. This corresponds to the histology of the lens epithelium published before.
Diabetic retinopathy (DR) is an inflammatory condition that affects the posterior of the eye; yet, there are limited published data on techniques measuring the expression of growth and inflammatory factors (GIF) from the posterior segment. The purpose of the current study was two-fold: to sample the vitreous fluid from the eyes of patients with DR and assess the expression of GIF. As DR is an inflammatory disease, the second objective of this study was to determine the relationship between the status of DR and the expression of vitreous GIF. This non-randomized clinical trial was approved by BfARM for the analysis and evaluation of 12 eyes from patients with diabetic macular edema. Vitreous sampling was performed before treatment with fluocinolone acetonide and the extracted vitreous material was examined for the determination of GIF including interleukins 6 (IL-6) and 8 (IL-8), interferon gamma-inducible protein (IP-10), monocyte chemoattractant protein-1 (MCP-1), placental growth factor (PIGF), pigment epithelium-derived factor (PEDF), VEGF (vascular endothelial growth factor) and intercellular adhesion molecule (CD54). These were linearly compared with the grade of inflammation in the vitreous assessed via DR score and ART. Additionally, all eyes were grouped based on their diabetic retinopathy status. All cytokine levels, except MCP-1 and PEDF, were numerically higher in DME patients with proliferative DR than those with non-proliferative DR. DR grade was found to linearly correlate with the expression of CD54 (p = 0.02, rho = 0.64), IL-8 (p = 0.03, rho = 0.64) and PIGF (p = 0.007, rho = 0.76). A correlation was found between ART and CD54 (p = 0.02, rho = 0.66) and also between ART and IL-8 (p = 0.04, rho = 0.60). A trend was found between ART and PIGF (p = 0.08, rho 0.52). For IL-6, there appeared to be a trend with DR grade (p = 0.14, rho = 0.45) and ART (p = 0.09, rho = 0.51). Proliferative DR was shown to be associated with a significant higher expression of CD54, IL-8 and PIGF, thus suggesting that they are potentially important in defining and monitoring the effectiveness of a patients’ therapy. Vitreous probes may be helpful in deciding which therapy to administer (i.e. anti-VEGF or corticosteroid or both) based on the expression of GIF. Registry EudraCT number: 2016-004488-38; DRKS-ID: DRKS00014915.
Zusammenfassung Hintergrund Die Ophthalmoskopie ist Bestandteil des medizinischen Curriculums, jedoch das Vermitteln der Inhalte oft unbefriedigend, da ein systematisches Lernen von Pathologien und deren Behandlungen dadurch erschwert ist, dass oftmals das passende Patientengut nicht zur Verfügung steht und dadurch gesunde Studenten einander untersuchen müssen. Aus diesem Grund haben wir eine Online-Plattform entwickelt, die in Kombination mit simulationsgestütztem Training sowohl das eigenständige als auch das angeleitete Lernen von Untersuchungsmethoden und Pathologien ermöglicht. Ziel der Arbeit Ziel der vorliegenden Arbeit war, ein Format für die Verbesserung der Lehre der direkten und indirekten Ophthalmoskopie im Studierendenunterricht zu evaluieren. Dabei wurden praktische Übungen an Virtual-Reality-basierten Simulatoren mit neu entwickelten und an den Lehrkatalog angepassten theoretischen Inhalten in der Online-Plattform EyesiNet verschränkt. Material und Methoden Die Studierenden bearbeiteten am ersten sowie am letzten Praktikumstag zufällig ausgewählte Fälle, die ihnen von den Eyesi Direct- und Eyesi Indirect-Simulatoren präsentiert wurden. Zwischen diesen beiden Einheiten konnten sie sich auf freiwilliger Basis mit den theoretischen Grundlagen typischer ophthalmologischer Krankheitsbilder im EyesiNet beschäftigen. Ergebnisse Eyesi Direct: Die Bewertung des Simulators ergab am ersten Praktikumstag für beide Gruppen keinen signifikant unterschiedlichen Wissensstand (p = 0,29). In der Gruppe OHNE Training (n = 54) ergab sich am letzten Praktikumstag mit p = 0,02 eine signifikante Verbesserung dieser Bewertung, jedoch mit einer geringen Effektgröße von 0,1. In der Gruppe MIT Training (n = 32) konnte mit p = 0,0004 eine hoch signifikante Verbesserung mit einer Effektgröße von 0,3 nach Rosenthal festgestellt werden. Eyesi Indirect: Die simulatorgestützte Bewertung ergab am ersten Praktikumstag keinen signifikanten Unterschied im Wissensstand der beiden Gruppen (p = 0,1). Nach dem Training schnitten zwar beide Gruppen etwas besser ab, jedoch ohne signifikanten Unterschied (OHNE Training p = 0,41/MIT Training p = 0,17). Diskussion Die Online-Plattform EyesiNet unterstützt beim Erlernen der wichtigsten Erkrankungsbilder. Lerninhalte werden reproduzierbar und auf für alle Lernenden standardisierte Weise zur Verfügung gestellt. Die Fertigkeiten der direkten Ophthalmoskopie sind hierbei deutlich schneller als die der indirekten Ophthalmoskopie zu erlernen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.