We conclude from our data that the XEN45 Gel Stent has an IOP-lowering potential and few side-effects. Pseudophakic eyes seem to have a better primary prognosis compared to combined surgery or surgery in phakic eyes.
.
Purpose: To test whether patients aged ≥80 years can safely and successfully apply eyedrops from a single‐use eyedrop container without support, and to compare the results with those of younger patients using single‐use containers and older patients using standard eyedrop bottles.
Methods: Patients aged ≥80 years who had no physical or mental conditions hindering self‐application of eyedrops and actually did so because of glaucoma or dry eyes were included consecutively in the study group (n = 44) in order to perform self‐application of eyedrops from single‐use eyedrop containers. Patients were observed meticulously by two investigators, who documented practical problems during the procedure in a checklist. In control group A (n = 22), glaucoma or sicca patients aged between 50 and 65 years applied drops from single‐use eyedrop containers; in control group B (n = 28), glaucoma or sicca patients aged ≥80 years used a traditional eyedrop bottle.
Results: Successful application of the drops into the conjunctival sac was achieved by 57% in the study group (95% and 89% in control groups A and B, respectively). Scratching of the eyedrop container along the conjunctiva or cornea was observed in 68% of the study group (41% and 61% in control groups A and B, respectively). Frequency of problems during opening and self‐application of single‐use eyedrop containers in the study group showed an inverse correlation to visual acuity in the better eye and previous experience with this kind of eyedrop container.
Conclusion: Older patients have massive problems in self‐administering eyedrops from single‐use containers. Factors influencing the success of self‐application may include the patient’s previous experience with this kind of eyedrop container and the patient’s visual acuity.
This novel surgical approach and the placement of the silicone tube described here have several advantages. Its intrascleral course minimizes the risk of conjunctival erosion and associated infections. No cyclodialysis is performed. Connection to the suprachoroidal space exploits the resorptive capability of the choroid. It guarantees drainage but also provides a natural counterpressure, avoiding severe postoperative hypotony. The suprachoroidal shunt presented here achieves good follow-up results in terms of IOP control. No serious complications have been observed. This new method promises to be an effective surgical technique and presents a new therapeutic option in intractable glaucoma. Fibroblast reaction obstructing the posterior lumen, seemed to be the only factor limiting drainage. Further studies and experiments will be needed to elucidate the exact physiologic mechanisms underlying the draining, the capacity and duration of the draining effect, and the histologic background of suprachoroidal scarring.
Implantation of a CTR had no consistent effect on refractive outcomes compared with routine phacoemulsification in highly myopic eyes. There was a tendency toward higher precision in outcomes with a CTR. Results indicate IOL power calculation does not have to be changed when a CTR is used.
A completely encapsulated intraocular pressure (IOP) sensor equipped with telemetric signal and energy transfer is introduced integrated into a silicone disc for implantation into the eye. After implantation into enucleated pig eyes and into rabbit eyes in vivo, the IOP was recorded and compared to established techniques of IOP measurement. Pressure chamber tests showed that the sensor functioned correctly after biocompatible encapsulation in polydimethylsiloxane. In vivo and in vitro tests in rabbit and pig eyes demonstrated that the implanted system worked with the same precision as established techniques for IOP determination. The correlation between the measurements with the implanted device and pneumotonometry in several experiments was between 0.9 and 0.99. This device serves as a functioning model for the realization of a telemetric IOP sensor for integration into an artificial intraocular lens. Such a device will open new perspectives, not only in the management of glaucoma, but also in basic research for mechanisms of glaucoma.
Optical biometry for intraocular lens power calculation seems to deliver reliable results for cataract surgery in patients with high myopia, although our data describe an increasing lack of accuracy beyond an axial length of 30mm. The Haigis formula provided the best predictability of postoperative refractive outcome for myopic eyes in general.
The triple procedure is more effective in lowering intraocular pressure compared to phacoemulsification and trabecular aspiration alone in pseudoexfoliation glaucoma.
Partial coherence laser interferometry shows good clinical practicability in silicone oil-filled eyes with previous complicated vitreoretinal surgery. Further studies are needed to assess the reliability of these measurements with regard to postoperative refraction after combined oil removal and cataract surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.