Inert gas washout tests, performed using the single-or multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. These benefits have led to a resurgence of interest in these techniques from manufacturers, clinicians and researchers, yet detailed guidelines for washout equipment specifications, test performance and analysis are lacking. This manuscript provides recommendations about these aspects, applicable to both the paediatric and adult testing environment, whilst outlining the important principles that are essential for the reader to understand. These recommendations are evidence based, where possible, but in many places represent expert opinion from a working group with a large collective experience in the techniques discussed.Finally, the important issues that remain unanswered are highlighted. By addressing these important issues and directing future research, the hope is to facilitate the incorporation of these promising tests into routine clinical practice.
biotalar fusion is considered to be the standard treatment for end-stage post-traumatic arthritis of the ankle. We report a retrospective, objective long-term study of the quality of life of 17 patients with 18 arthrodeses of the ankle, over a period of more than 20 years. We looked particularly for correlation between clinical and radiological signs of osteoarthritis in adjoining joints. At serial physical examinations, clinical grades were awarded according to the Olerud Molander Ankle (OMA) score. Any degree of degenerative change in the adjoining joints was recorded on standing radiographs. Patients filled out a SF-36 Health Survey form. Subjectively, 50% of patients were not handicapped in the performance of daily activities and 44% were in the same job as at the time of injury. At follow-up the mean OMA score was 59.4 points, the visual analogue scale was 1.99 and the radiological score was 2.7. The SF-36 for physical function, emotional disturbance and bodily pain revealed significant deficits. There was a significant correlation between the OMA and the radiological score (p = 0.05), and between the clinical and the SF-36 score (p = 0.01), but no significant correlation between the radiological score and the SF-36 score. Arthrodesis of the ankle leads to deficits in the functional outcome, to limitations in the activities of daily living and to radiological changes in the adjoining joints. The clinical outcome score correlates closely with the SF-36 score.
Although pulmonary function testing plays a key role in the diagnosis and management of chronic pulmonary conditions in children under 6 years of age, objective physiologic assessment is limited in the clinical care of infants and children less than 6 years old, due to the challenges of measuring lung function in this age range. Ongoing research in lung function testing in infants, toddlers, and preschoolers has resulted in techniques that show promise as safe, feasible, and potentially clinically useful tests. Official American Thoracic Society workshops were convened in 2009 and 2010 to review six lung function tests based on a comprehensive review of the literature (infant raised-volume rapid thoracic compression and plethysmography, preschool spirometry, specific airway resistance, forced oscillation, the interrupter technique, and multiple-breath washout). In these proceedings, the current state of the art for each of these tests is reviewed as it applies to the clinical management of infants and children under 6 years of age with cystic fibrosis, bronchopulmonary dysplasia, and recurrent wheeze, using a standardized format that allows easy comparison between the measures. Although insufficient evidence exists to recommend incorporation of these tests into the routine diagnostic evaluation and clinical monitoring of infants and young children with cystic fibrosis, bronchopulmonary dysplasia, or recurrent wheeze, they may be valuable tools with which to address specific concerns, such as ongoing symptoms or monitoring response to treatment, and as outcome measures in clinical research studies.
A single course of three SH injections is effective in relieving pain and improving joint function in patients with OA of the CMC joint of the thumb. Although in comparison with triamcinolone its effects are achieved more slowly, the results indicate a superior long-lasting effect of hyaluronan at 6 months after end of treatment period.
There is increasing interest in using the Multiple Breath Washout technique and the lung clearance index (LCI) for detecting early pulmonary changes, for example, in cystic fibrosis lung disease. However, there are still limited data regarding equipment specific reference ranges, repeatability and reproducibility. The aim of this prospective study was to assess within-test repeatability, short term reproducibility and long term reproducibility, and to establish normal values for the LCI in healthy children and adolescents using the sidestream ultrasonic flow sensor (EasyOne Pro, MBW Module, ndd Medical Technologies, Switzerland). Fourty-four volunteers (5.3-20.3 years) were recruited for the 1st test. Twenty-two out of 44 were measured on a 2nd test occasion after an interval of 1 hr (2nd test). Thirty-four out of 44 agreed to come back for a follow up test 6-15 months later (3rd test). Mean LCI (SD) was 6.2 (0.4), 6.3 (0.4), and 6.0 (0.4) at the 1st, 2nd, and 3rd test. The upper limit of normal was 7.0 for all subjects. Within-test repeatability was 5.1%. Short-term reproducibility (1st test vs. 2nd test) was 4.2% with a mean difference of -0.13 (95% CI -0.350; 0.087). Long-term reproducibility (1st test vs. 3rd test) was 5.1%, with a mean difference of 0.017 (95% CI -0.016; 0.348). With this low variability of the LCI for both, within and between tests, our study demonstrates reliability and robustness of equipment, protocol and analysis and the reliability of the MBW technique in general. The present data will help to interpret the effect of therapeutic interventions and interpretation of longitudinal data in patients with pulmonary diseases.
Open and closed wedge HTOs obtain significant improvement in patients with medial osteoarthritis of the knee. Using the right technique is very important for good results. For stabilization of the medial ligament we recommend the open wedge osteotomy. The patient should be informed about the routine removal of the metal plate.
It is widely accepted that CF lung disease starts before clinical symptoms become apparent or spirometry deteriorates. Computed chest tomography (CT) is the reference method for identifying structural changes in CF; however, radiation exposure limits its use as a monitoring tool. It has been suggested that the Lung Clearance Index (LCI) measured by Multiple Breath Washout (MBW) for assessing ventilation inhomogeneity is a more sensitive surrogate marker than spirometry allowing non-invasive monitoring of CF lung disease. The aim of this study was to prospectively investigate the diagnostic accuracy of the LCI in comparison to CT in CF patients with early lung disease and normal FEV(1) (>80% pred.). MBW and ultra-low-dose CT were performed in 34 patients (6-26 years). LCI was abnormal in 76.5% subjects. LCI and CT correlated significantly in 82.3%. LCI was related to presence and extent of structural lung changes observed on CT with a sensitivity of 88%. Diagnostic accuracy of the LCI for detecting CF lung disease in patients with normal FEV(1) was good when compared to CT. Results indicate that structural changes are unlikely if a normal LCI is measured. We speculate that serial measurements of the LCI for assessing ventilation inhomogeneity may help to identify early structural lung disease and help to reduce the individual cumulative radiation dose. The LCI may be a suitable surrogate marker for monitoring progression of CF lung disease and effect of treatment in both, clinical care and research settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.