Background The World Health Organization (WHO) has developed the Integrated Care for Older People (ICOPE) strategy to face the challenges of ageing societies. This strategy is focused on person centered care and the assessment intrinsic capacity (IC). Early identification of five domains of IC (cognition, locomotion, vitality, sensory (hearing and vision), and psychological) has been shown to be related with adverse outcomes and can guide actions towards primary prevention and healthy ageing. IC assessment proposed by the WHO ICOPE guidelines is composed by two steps: First, Screening for decreased IC by the ICOPE Screening tool; second, by the reference standard methods. The aim was to assess the performance of diagnostic measures (sensibility, specificity, diagnostic accuracy, and agreement of the ICOPE Screening tool) compared to the reference standard methods in European community-dwelling older adults. Methods Cross-sectional analysis of the baseline of the ongoing VIMCI (Validity of an Instrument to Measure Intrinsic Capacity) cohort study, which was carried out in Primary Care centers and outpatient clinics from 5 rural and urban territories in Catalonia (Spain). Participants were 207community dwelling persons ≥ 70-year-old with Barthel $$\ge$$ ≥ 90, without dementia or advanced chronic conditions who provided their consent to participate. The 5 IC domains were assessed by the ICOPE Screening tool and the reference methods (SPPB, gait speed, MNA, Snellen chart, audiometry, MMSE, GDS5) during patients’ visit. Agreement was assessed with the Gwet AC1 index. Results ICOPE Screening tool sensitivity was higher for cognition (0.889) and ranged between 0.438 and 0.569 for most domains. Specificity ranged from 0.682 to 0.96, diagnostic accuracy from 0.627 to 0.879, Youden index from 0.12 to 0.619, and Gwet AC1 from 0.275 to 0.842. Conclusion The ICOPE screening tool showed fair performance of diagnostic measures; it was helpful to identify those participants with satisfactory IC and showed a modest ability to identify decreased IC in older people with high degree of autonomy. Since low sensitivities were found, a process of external validation would be recommended to reach better discrimination. Further studies about the ICOPE Screening tool and its performance of diagnostic measures in different populations are urgently required.
Background: The WHO has developed the Integrated Care for Older People (ICOPE) strategy to face the challenges of ageing societies. This strategy is focused on person centered care and the assessment intrinsic capacity (IC). Early identification of five domains of IC (cognition, locomotion, vitality, sensory (hearing and vision), and psychological) has been shown to be related with adverse outcomes and can guide actions towards primary prevention and healthy aging. IC assessment proposed by the WHO ICOPE guidelines is composed by two steps: First, Screening for IC declines in IC by the ICOPE Screening tool; second, by the reference standard methods. The aim was to assess the diagnostic performance indicators (sensibility, specificity, diagnostic accuracy, and agreement of the ICOPE Screening tool) compared to the reference standard methods in European community-dwelling older adults. Methods: Cross-sectional analysis of the baseline of the ongoing VIMCI cohort study, which was carried out in Primary Care centers and outpatient clinics from 5 rural and urban territories in Catalonia (Spain). Participants were 207community dwelling persons ≥ 70-year-old with Barthel ≥ 90, without dementia or advanced chronic conditions who provided their consent to participate. The 5 IC domains were assessed by the ICOPE Screening tool and the reference methods (SPPB, gait speed, MNA, Snellen chart, audiometry, MMSE, GDS5) during patients’ visit. Agreement was assessed with Gwet AC1 index. Results: ICOPE Screening tool sensitivity was higher for cognition (0.889) and ranged between 0.438 and 0.569 for most domains. Specificity ranged from 0.682 to 0.96, diagnostic accuracy from 0.627 to 0.879, Youden index from 0.12 to 0.619, and Gwet AC1 from 0.275 to 0.842 Conclusion: The ICOPE screening tool showed fair diagnostic performance indicators; it was helpful to identify those participants with satisfactory IC and showed a modest ability to identify IC decline in older people with high degree of autonomy. This limitation may be overcome by repeating periodically the screening in those with satisfactory screening for IC. The screening for IC could be considered for implementation into clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.