Two multichannel tactile devices for the hearing impaired were compared in speech perception tasks of varying levels of complexity. Both devices implemented the "vocoder" principle in their stimulus processing: One device had a 16-element linear vibratory array worn on the forearm and displayed activity in 16 overlapping frequency channels; the other device delivered tactile stimulation to a linear array of 16 electrodes worn on the abdomen. Subjects were tested in several phoneme discrimination tasks, ranging from discrimination of pairs of words differing in only one phoneme under tactile aid alone conditions to identification of stimuli in a larger set under tactile aid alone, lipreading alone, and lipreading plus tactile aid conditions. Results showed both devices to be better transmitters of manner and voicing features of articulation than of place features, when tested in single-item tasks. No systematic differences in performance with the two devices were observed. However, in a connected discourse tracking task, the vibrotactile vocoder in conjunction with lipreading yielded much greater improvements over lipreading alone than did the electrotactile vocoder. One possible explanation for this difference in performance, the inclusion of a noise suppression circuit in the electrotactile aid, was evaluated, but did not appear to account for the differences observed. Results are discussed in terms of additional differences between the two devices that may influence performance.
Abstract-Although the results from a number of studies of the performance of lnultichannel tactile aids for speech perception have suggested that such devices might provide more benefit to hearing-impaired persons than single-channel tactile aids (3,4). recent studies involving direct comparisons of multichannel and single-channel vibrotactile aids (5,6) indicated otherwise. In hct. for some types of speech inforlnation. such as rhythm and stress perception. single-channel aids were shown to be superior. The present study attempted to address this apparent discrepancy by comparing the performance of two single-channel devices with two nlultichannel devices in a variety of speech perception tasks including both single-item and connected speech stin~uli. Results indicated that the two classes of tactile device perforriled sirnilarly in rhythm and stress perception. but that the multichannel aids in many cases showed better perfhrmance for tasks in which the identification of fine-structure phoneme information was required (both single-item and connected speech). Results are discussed in terms of the possibility that the performance of a specific multichannel tactile aid cannot be considered indicative of all devices of the sarne class.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.