Purpose: To investigate if imaging with intravascular ultrasound (IVUS) yields a more accurate estimate of vessel diameter and the presence of dissections after intervention when treating the infrapopliteal arteries. Materials and Methods: A prospective, single-center study enrolled 20 consecutive patients (mean age 74.1±12.4 years; 12 women) with infrapopliteal disease who were treated with PTA (n=10) or orbital atherectomy (OA) followed by PTA (n=10). The majority of patients were hypertensive and half were diabetic. The overall lesion length was 7.3±6.3 cm, and the diameter stenosis was 80.3%±22.1%. The baseline characteristics did not differ between the groups. Vessel diameters were measured using IVUS from the internal elastic lamina (IEL) to the IEL. IVUS was performed at baseline, post PTA or OA, and post OA+PTA. Quantitative vascular angiography (QVA) and IVUS were analyzed by a core laboratory. Dissections on cine images were categorized based on the National Heart Lung and Blood Institute (NHLBI) classification, while the arc and depth were used to characterize dissections on IVUS images. Results: Mean vessel diameter by QVA was 2.9±0.6 vs 4.0±1.0 mm by IVUS according to the core laboratory (mean difference 1.1±0.9, p<0.001). On angiography, there were 7 dissections after PTA (6 C, 1 D), 1 dissection after OA (1 B), and 2 dissections after OA+PTA (1 A, 1 B; p=0.028 vs post PTA). IVUS uncovered 3.8 times more dissections than seen on angiography. There were 23 dissections after PTA (18 intima, 3 media, 2 adventitia), 12 dissections after OA (8 intima, 1 media, 3 adventitia), and 11 dissections following OA+PTA (7 intima, 1 media, 3 adventitia; p=0.425 vs PTA). Bailout stenting (all due to angiographic dissections ≥C) was necessary in 6 of the PTA cohort and none of the OA+PTA group. Conclusion: In addition to underestimating the infrapopliteal vessel diameter by ~25%, angiography underappreciated the presence and severity of post-intervention dissections vs IVUS, particularly in the OA+PTA group.
Background Femoropopliteal arterial angiographic dissections with the use of the Auryon laser atherectomy system (previously the B-laser) have been infrequent and non–flow limiting. However, the pattern of these dissections (depth and arc) using intravascular ultrasound remains unknown. Materials and Methods We prospectively enrolled 29 patients in the iDissection Auryon study. The primary objective was to define the occurrence of new adventitial injury with intravascular ultrasound (IVUS). Secondary objectives included distal embolization and bailout stenting as judged by the operator because of 30% or more residual narrowing and/or NHLBI (National Heart, Lung, and Blood Institute) angiographic dissection C and higher. Core laboratory analysis was carried on all cases except for 1 patient (that crossed over to Jetstream atherectomy). Dissections were classified according to the iDissection classification as involving the intima (A), media (B), and adventitia (C) and ≤ 180-° arc (1) or >180-° arc (2). Overall, 22 of 29 patients had an embolic filter (per protocol). Results Median lesion and treated lengths were 100.0 and 150.0 mm, respectively. Vessel diameter by IVUS was 6.5 ± 1.5 mm. Chronic total occlusion (CTO) was present in 24.1% of cases. The arc of calcium was: no calcium in 27.6%, <90° in 13.8%, 90° to 180° in 20.7%, and >180° in 34.4%. Lesion severity was reduced to a median of 14% post laser and adjunctive percutaneous transluminal angioplasty (PTA) from a baseline of 76%. Bailout stenting occurred in 6 of 28 (21.4%) patients (3 for dissections, 2 for residual >30%, and 1 for both) and primary stenting in 1 of 28 (3.6%). By IVUS, there were 9 new dissections post laser (1 adventitial; 3≥180°) and 21 new dissections post laser and PTA (3 adventitial; 1≥180°). No distal embolization requiring treatment was seen and no macrodebris ≥2 mm was recovered in the filters. Conclusion The Auryon laser atherectomy system had minimal rate of adventitial injury despite complex disease with relatively low bailout stent rate and no clinically significant macrodebris.
Purpose: To report the results of a study evaluating JetStream atherectomy for the treatment of in-stent restenosis (ISR). Materials and Methods: The JetStream XC atherectomy device, a rotational cutter with aspiration capacity, was evaluated in a prospective, multicenter study (JET-ISR) of 60 patients (mean age 70.2±10.8 years; 40 men) with femoropopliteal ISR ( ClinicalTrials.gov identifier NCT02730234). Lesion length was 19.9±13.5 cm; 33 (55%) were chronic total occlusions and 26 (45%) were TransAtlantic Inter-Society Consensus class D. No drug-bearing device was allowed, and stenting was performed only for bailout. Lesion characteristics and stent integrity were evaluated by an independent core laboratory. The primary endpoint was target lesion revascularization (TLR) at 6 months with bailout stenting considered as TLR. Secondary endpoints included TLR (without bailout stenting) and clinical patency (no restenosis or TLR) at 1 year. The Kaplan-Meier method was employed to evaluate time-to-event endpoints; estimates are given with 95% confidence interval (CI). Results: Bailout stenting was required in 6 of 60 limbs (10%). There were no stent fractures or deformities after atherectomy + adjunctive angioplasty reported by the core laboratory. Kaplan-Meier estimates of freedom from TLR at 6 months and 1 year were 79.3% (95% CI 68.9% to 89.8%) and 60.7% (95% CI 47.8% to 73.6%), respectively. When bailout stenting at the index procedure was not considered a TLR event, freedom from TLR estimates at 6 months and 1 year were 89.3% (95% CI 81.2% to 97.4%) and 66.8% (95% CI 54.3% to 74.2%), respectively. Clinical patency rates at 6 months and 1 year were 77.5% (31/40) and 51.7% (15/29), respectively. Conclusion: JetStream atherectomy using the XC device and no drug-eluting devices is feasible, with good clinical patency and 1-year freedom from TLR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.