Conducting polymers hold significant promise as electrode coatings; however, they are characterized by inherently poor mechanical properties. Blending or producing layered conducting polymers with other polymer forms, such as hydrogels, has been proposed as an approach to improving these properties. There are many challenges to producing hybrid polymers incorporating conducting polymers and hydrogels, including the fabrication of structures based on two such dissimilar materials and evaluation of the properties of the resulting structures. Although both fabrication and evaluation of structure-property relationships remain challenges, materials comprised of conducting polymers and hydrogels are promising for the next generation of bioactive electrode coatings.
A hybrid system for producing conducting polymers within a doping hydrogel mesh is presented. These conductive hydrogels demonstrate comparable electroactivity to conventional conducting polymers without requiring the need for mobile doping ions which are typically used in literature. These hybrids have superior mechanical stability and a modulus significantly closer to neural tissue than materials which are commonly used for medical electrodes. Additionally they are shown to support the attachment and differentiation of neural like cells, with improved interaction when compared to homogeneous hydrogels. The system provides flexibility such that biologic incorporation can be tailored for application.
Conducting polymers have often been described in literature as a coating for metal electrodes which will dampen the mechanical mismatch with neural tissue, encouraging intimate cell interactions. However, there is very limited quantitative analysis of conducting polymer mechanics and the relation to tissue interactions. This article systematically analyses the impact of coating platinum (Pt) electrodes with the conducting polymer poly(ethylene dioxythiophene) (PEDOT) doped with a series of common anions which have been explored for neural interfacing applications. Nanoindentation was used to determine the coating modulus and it was found that the polymer stiffness increased as the size of the dopant ion was increased, with PEDOT doped with polystyrene sulfonate (PSS) having the highest modulus at 3.2 GPa. This was more than double that of the ClO4 doped PEDOT at 1.3 GPa. Similarly, the electrical properties of these materials were shown to have a size dependent behavior with the smaller anions producing PEDOT films with the highest charge transfer capacity and lowest impedance. Coating stiffness was found to have a negligible effect on in vitro neural cell survival and differentiation, but rather polymer surface morphology, dopant toxicity and mobility is found to have the greatest impact.
Bioelectrodes for neural recording and neurostimulation are an integral component of a number of neuroprosthetic devices, including the commercially available cochlear implant, and developmental devices, such as the bionic eye and brain-machine interfaces. Current electrode designs limit the application of such devices owing to suboptimal material properties that lead to minimal interaction with the target neural tissue and the formation of fibrotic capsules. In designing an ideal bioelectrode, a number of design criteria must be considered with respect to physical, mechanical, electrical and biological properties. Conducting polymers have the potential to address the synergistic interaction of these properties and show promise as superior coatings for next-generation electrodes in implant devices.
Nanofluids have been increasingly used in a wide range of thermal applications. Although these applications can benefit greatly from investigating the behavior of nanoparticles under different heating scenarios, there is a lack of experiments that can achieve this. To overcome this challenge, an optical "pump-probe"-type experiment is suggested in this paper. In experiments of this type, a set of "pumping" nanoparticles are specifically selected to absorb laser radiation. These particles represent a flexible tool for volumetric heating. A second set of "probing" nanoparticles can be tailored to scatter a separate optical probing signal. This work presents a selection procedure for nanoparticles of both types. The selection procedure is then demonstrated for a specific example where the pump and probe wavelengths are of 980 and 532 nm, respectively. Gold nanorods with diameters of 10 and a length of 58 nm are selected as the "most suitable" absorbing particles, while silver nanospheres with a diameter of 110 nm are selected as the "most suitable" scattering particles. These particles are synthesized and shown to experimentally match the desired optical properties. Overall, this paper proposes and demonstrates an approach by which it is possible to design and fabricate particles for a wide range of optical studies in semi-transparent nanofluids.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.