The aim of this study was to assess the feasibility of a cephalic vein cutdown and venography technique for implantation of a pacemaker or ICD and to determine the causes of failure of cephalic vein cutdown. In consecutive patients who underwent pacemaker or ICD implants, a modified cephalic vein guidewire technique was performed. This technique was attempted in 289 pacemaker implants and 26 ICD implants (155 men, 160 women; mean age 74 +/- 10 years). The success rate for implantation of a single chamber and a dual chamber device by using this technique alone was 84% (54/64) and 74% (185/251), respectively (P = 0.10). In an additional 7% of patients with dual chamber implant, the cephalic vein can be used for passage of the ventricular lead. A cephalic venogram was required in 82 patients and facilitated the passage of the guidewire in 62 (79%) of them. No complication related to vascular access was observed with this technique. This technique failed in 54 (17%) of 315 patients due to (1) failure of cephalic vein isolation (48%), (2) venous stenosis (24%), or (3) venous torturosity or anomalies (28%). There were no significant differences in the patient's age, sex, type of device, and the fluoroscopic time for lead placement between patients with or without successful lead placement using this technique (all P > 0.05). In conclusion, a simple modification of the cephalic vein guidewire technique together with venography has facilitated the placement of leads during pacemaker and ICD implant. This technique is safe and applicable in the majority of patients and avoids the risk of subclavian puncture.
AF with a fast ventricular response may cause ventricular mechanical impairment, though whether short-lasting AF with satisfactory rate control may affect ventricular function is unknown. This study investigated if prompt cardioversion by an implantable atrial defibrillator (IAD) may prevent left (LV) and right ventricular (RV) systolic and diastolic dysfunction. Ten patients (mean age 61 +/- 9 years, 8 men) with paroxysmal AF without structural heart disease who received an IAD were studied by echocardiography and tissue Doppler imaging (TDI) for both ventricles. Measurements were made during baseline sinus rhythm and at 1-minute, 20-minute, 4-hour, and 1-week postcardioversion of an episode of spontaneous AF. The occurrence of AF and the ventricular rate were monitored at 2-hour intervals by the device. There were 50 episodes of AF with a mean duration of 8.8 +/- 8.9 days (2 hours to 37 days). There was no difference in M-mode measured LV fractional shortening and ejection fraction between baseline sinus rhythm and after cardioversion. However, the TDI derived myocardial systolic velocity (TDI-S) was significantly lower at 1-minute postcardioversion and was normalized at 1 week in both LVs (baseline: 5.7 +/- 1.8, 1 minute: 4.2 +/- 1.0, 20 minutes: 4.3 +/- 0.9, 4 hours: 4.8 +/- 1.0, 1 week: 5.5 +/- 1.8 cm/s; P < 0.005 when comparing 1 minute and 20 minutes to baseline; P < 0.05 when comparing 4 hour to baseline) and RV (baseline: 10.4 +/- 2.1, 1 minute: 7.8 +/- 1.4, 20 minutes: 8.1 +/- 1.2, 4 hours: 9.2 +/- 1.5, 1 week: 10.0 +/- 2.0 cm/s; P < 0.005 when comparing 1 minute, 20 minutes, and 4 hours to baseline). For diastolic function, transmitral Doppler study showed a decrease in early filling velocity at 1 minute (P < 0.05) and 20 minutes (P < 0.005), which was normalized at 4 hours. There was no change in transtricuspid Doppler flow. However, TDI derived myocardial early filling velocity was decreased in the LV (baseline: 6.0 +/- 2.8, 1 minute: 5.4 +/- 2.3, 20 minutes: 5.4 +/- 2.1, 4 hours: 6.1 +/- 2.2, 1 week: 5.8 +/- 1.7 cm/s; P < 0.05 when comparing 1 minute and 20 minutes to baseline) and RV (baseline: 8.9 +/- 3.5, 1 minute: 7.9 +/- 3.3, 20 minutes: 8.1 +/- 3.3, 4 hours: 8.5 +/- 2.9, 1 week: 8.4 +/- 3.5 cm/s; P < 0.05 when comparing 1 minute to baseline). AF of a longer duration (> 48 hours) resulted in a more depressed TDI-S in LV (> 48 hours: 4.2 +/- 1.0, < or = 48 hours: 5.3 +/- 1.3 cm/s; P < 0.01). Shocks in sinus rhythm did not affect any of the above echocardiographic parameters. Therefore, despite adequate rate control, short-lasting AF impairs systolic and diastolic function in both ventricles, which improves gradually after cardioversion. Early restoration of sinus rhythm by an IAD minimizes ventricular dysfunction. TDI is a sensitive tool to assess early systolic and diastolic dysfunction.
Automatic mode switching (AMS) prevents tracking of paroxysmal atrial fibrillation (AF) in dual chamber pacing. The correct detection of AF can be affected by the programmed atrial sensitivity (AS). We prospectively studied the relationship between AS, AF undersensing, and AMS, using unfiltered bipolar intracardiac atrial electrograms recorded from 17 patients during sinus rhythm (SR) and in AF. Overall, 780 rhythms were recorded and replayed onto three dual chamber pacemaker models using different AMS algorithms (Thera DR 7940, Marathon DDDR 294-09, and Meta DDDR 1254), and the ventricular responses were measured. AS was randomly programmed in steps from the highest available AS to half of the mean atrial P wave amplitude (PWA), and the percentage of appropriate AMS responses (defined as a ventricular pacing rate at the expected AMS mode) were recorded. AMS efficacy was related to the programmed AS settings in an exponential manner. At low AS settings, a higher percentage of tests were associated with absence of, or with intermittent AMS and tracking of AF, whereas at higher AS, oversensing of noise during SR occurred. An optimal AS measured approximately 1.3 mV, representing about one-third of the PWA measured during SR, although oversensing of SR and undersensing of AF continued to occur in 14% of tests and time, respectively, due to the high variation in PWA during AF. Thus, a fixed AS cannot eliminate AF undersensing without inviting noise oversensing, suggesting the need for automatic adjustments of AS, or the use of a rate-limiting algorithm to prevent rate oscillation during intermittent AF sensing. In conclusion, AMS functions of existing pacemakers were significantly limited by the undersensing of AF and oversensing of noise. Proper adjustment of the AS is important to enable effective AMS during AF.
LEUNG, S.-K., ET AL.: Automatic Optimization of Resting and Exercise Atrioventricular Interval Using a Peak Endocardial Acceleration Sensor: Validation with Doppler Echocardiography and Direct Cardiac Output Measurements. Peak endocardial acceleration (PEA) measured by an implantable acceleration sensor inside the tip of a pacing lead reflects ventricular filling and myocardial contractility. The contri bution of the plateau phase of PEA as an indicator of optimal ventricular filling, hence of the appropriate atrioventricular interval (AVI) at rest and during exercise, was studied in 12 patients (age 69 ± 6 years) with complete A V block anda PEA sensing DDDR pacemakers (Living 1 Plus, Sorin Biomedica). At a mean resting heart rate of 79 ± 15 beats/min, the mean AVI optimized by PEA versus Doppler echocardiogra phy (echo) were identical (142 ± 37 vs 146 ± 26 ms, P = 0.59). During submaximal exercise at a mean heart rate of 134 ± 6 beats/min, AVI optimized by PEA was 135 ± 37 ms. Cardiac output at rest, measured by the C0 2 rebreathing method, was comparable with AVI determined by echo versus PEA (4.3 ± 2.9 and 3.7 ± 2.4 L/min, respectively), and increased to the same extent (8.0 ± 3.9 vs 8.3 ± 5.2 L/min) during submaximal exercise. In patients with AV block, AVI automatically set by PEA was comparable with AVI manually optimized by Doppler echocardiography and was associated with comparable exercise induced hemodynamic changes. (PACE 2000; 23[Pt. II]:1762-1766) atrioventricular interval, peak endocardial acceleration, Doppler echocardiography, cardiac output
Floating P wave sensing can be derived from bipolar atrial electrodes with different electrode configurations, although the relative clinical efficacy of these methods of atrial sensing has not been studied. We evaluated 32 sex and age matched patients with advanced AV block who received AV synchronous pacers using either a single lead with diagonally arranged bipole (Unity VDDR, Model 292, Intermedics Inc.) or closely spaced bipolar complete ring electrodes (Thera VDD, Model 8948, Medtronic Inc.). The total surface area of the atrial electrodes were 17.2 and 25 mm2, and the highest programmable atrial sensitivities were 0.1 and 0.25 mV, respectively. Atrial electrogram amplitude and sensing threshold were evaluated at implant and at each follow-up clinic visit (1, 3, and 6 months). Stability of atrial sensing was assessed during physical maneuvers, treadmill exercise test, and Holter recording. Atrial electrogram amplitude at implantation was higher in the Thera VVD (2.08 +/- 0.79 vs 1.45 +/- 0.59 mV in Unity VDDR; P < 0.05), but the value of atrial sensing threshold was lower during follow-up than Unity VDDR. P wave undersensing was additionally observed with both pacemakers during physical maneuvers and exercise testing (6%-19% of patients). Two and four patients had atrial undersensing on Holter in the Unity VDDR and Thera VDD, respectively, and the percentage P wave undersensing were 0.88% +/- 2.41% versus 3.63% +/- 8.16%, respectively. Reprogramming of the atrial sensitivity in the Unity VDDR and the use of investigational software allowing 0.18 mV atrial sensitivity to be programmed in the Thera VDD substantially reduced the percentage of P wave undersensing on Holter to 0.46% +/- 1.67% and 0.10% +/- 0.24%, respectively. Beginning at discharge with a programmed atrial sensitivity level at least twice the sensing margin, the mean atrial sensitivity level was reprogrammed from 0.29 to 0.26 mV for Unity VDDR and 0.33 to 0.24 mV for Thera VDD at 6 months. There was no incidence of atrial oversensing. Despite differences in atrial amplitudes at implantation between the diagonally arranged bipole and closely spaced full ring single lead systems, the clinical performances of atrial sensing were similar at an appropriately high atrial sensitivities. The absence of atrial oversensing suggests that single pass VDD pacemakers should probably be programmed at the highest available atrial sensitivity to ensure adequate P wave sensing as guided by physical maneuvers and Holter recording to minimize the need of subsequent reprogramming.
Overdrive right atrial pacing has been used to prevent atrial fibrillation, but its efficacy in atrial fibrillation prevention and the patient tolerability and quality of life during high rate pacing remain uncertain. The objective of this study was to test the effects of a consistent atrial pacing algorithm that automatically paced the atrium at 30 ms shorter than the sinus P-P interval for atrial fibrillation prevention. Fifteen patients with sick sinus syndrome implanted with a Thera DR (model 7940 or 7960, Medtronic Inc.) were randomly programmed to rate adaptive dual chamber pacing (DDDR) or DDDR + consistent atrial pacing mode, each for an 8-week study period. The efficacy of consistent atrial pacing was assessed by the number of automatic mode switching and the number of premature atrial complexes. Symptoms and quality of life were assessed by the SF-36 quality of life questionnaire and an atrial fibrillation symptom checklist. The percentage of atrial pacing increased from 57 +/- 32% to 86 +/- 28%. Overall, there was no significant difference in the number of automatic mode switching episodes between DDDR and DDDR + consistent atrial pacing (47 +/- 90 vs 42 +/- 87, P > 0.05), but a significant reduction in premature atrial complexes by 74.7% (P < 0.001). There was no undue increase in atrial rate by the DDDR + consistent atrial pacing mode versus DDDR (63 +/- 13 vs 70 +/- 7 bpm). There was no significant difference in quality of life scores and symptom severity on frequency between the two modes of pacing, but a trend towards a lower frequency of symptoms in the DDDR + consistent atrial pacing mode compared with baseline (29.5 +/- 10.2 vs 25.1 +/- 9.7, P = 0.07). An algorithm that provides consistent atrial overdrive pacing can suppress atrial fibrillation triggering premature atrial complexes without the need to increase the overall atrial rate compared with conventional pacing. The algorithm appears to be well-tolerated, but further studies are needed to address the clinical impact of this atrial fibrillation prevention algorithm.
Automatic mode switching (AMS) is now a programmable function in most contemporary dual chamber pacemakers. Atrial tachyarrhythmias are detected when the sensed atrial rate exceeds a "rate-cutoff," "running average," "sensor-based physiological" rate, or using "complex" detection algorithms. AMS algorithms differ in their atrial tachyarrhythmia detection method, sensitivity, and specificity and, thus, respond differently to atrial tachyarrhythmia in terms of speed to the AMS onset, rate stability of the response, and speed to resynchronize to sinus rhythm. AMS is hemodynamically beneficial, and most patients with atrial tachyarrhythmias are symptomatically better with an AMS algorithm in their pacemakers. New diagnostic capabilities of pacemaker especially stored electrograms not only allow programming of the AMS function, but enable quantification of atrial fibrillation burden that facilitate clinical management of patients with implantable devices who have concomitant atrial tachyarrhythmia.
Optimal function of a single lead P wave synchronous rate adaptive ventricular pacing system (VDDR) requires reliable P wave sensing over time and during daily activities. The stability of P wave sensing and the incidence of sensitivity reprogramming in a single pass lead with a diagonally arranged bipole was assessed in 30 patients with complete atrioventricular block over a follow-up period of 12 +/- 1 months (range 6 months to 3 years). Atrial sensing was assessed during clinic visits, by physical maneuvers (postural changes, breathing, Valsalva maneuver, walking and isometric exercise), maximum treadmill exercise and Holter recordings. P wave amplitude at implantation was 1.21 +/- 0.09 (0.5-3.6) mV, and the atrial sensing threshold remained stable over the entire period of follow-up. Using an atrial sensitivity based on twice the sensing threshold at 1 month, P wave undersensing was found in 2, 4, 3, and 7 patients during clinic visit, physical maneuvers, exercise, and Holter recordings, respectively. Atrial sensitivity reprogramming was performed in three patients based on the correction of undersensing during physical maneuvers. Although eight patients had atrial undersensing on Holter recordings, the number of undersensed P waves was small (total 101 beats or 0.013% +/- 0.001% of total ventricular beats) and no patient was symptomatic. One patient had intermittent atrial undersensing at the highest sensitivity, but the VDDR mode was still functional most of the time. No patient had myopotential interference at the programmed sensitivity. One patient developed chronic atrial fibrillation and was programmed to the VVIR mode. Thus, single lead VDDR pacing is a stable pacing mode in 97% of patients.(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.