ROCThis study investigated the influence of operating parameters on the efficiency of collection of street dust using a street scrubber. Street scrubbing tests were performed in a full-scale, street scrubbing testing field, and on roads. The full-scale testing field was 40 m long and 1.95 m wide, specifically designed and constructed for this study. It was operated semi-automatically. The operating parameters investigated included nozzle type, street dust load, scrubbing speed, water injection loading, water injection pressure, distance above the ground, and water injection angle. 17.15±4.77 g/m 2 ) were used. The experimental results showed that, during scrubbing, the efficiency of collection of street dust decreased as street dust loading, scrubbing speed and distance above the ground increased, but increased with water injection loading and pressure. The determined optimal operating parameters were a scrubbing speed of less than 15 km/hr, a water injection loading of 0.8 L/m 2 , a water injection pressure of 2.0 kg/m 2 , distance above the ground of 30 cm and a water injection angle of 45 o . Additionally, the efficiency of collection of fine particles was higher than that of coarse particles. A multiple regression model was developed to predict the collection efficiency of street dust, based on experimental results obtained from street scrubbing field tests. The results suggested that street scrubbing should be able to reduce the fugitive emissions of street dust from paved roads.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.