The 19-year-old male population in Seoul, Korea, demonstrated a very high myopic prevalence. Myopic refractive error was associated with academic achievement, not with body stature.
PurposeThis study reports on the long-term surgical outcomes after the insertion of porous Medpor orbital implants into anophthalmic sockets.MethodsA retrospective chart review of 314 eyes from 314 patients who underwent evisceration, enucleation and secondary procedures using Medpor orbital implants was completed focusing on implant-associated complications and their corrective methods as surgical outcomes.ResultsThe mean follow-up was 50 months (range 6–107 months). The most common complication was blepharoptosis (n=33, 10.5%). Other postoperative complications were exposure (n=14, 4.5%) and implant infection (n=3, 1%). The complications were successfully managed by surgical repair and/or conservative care.ConclusionUsing Medpor resulted in similar surgical outcomes, in terms of the types and frequencies of complications, as other kinds of porous orbital implants.
Predicting fluid responsiveness in patients under mechanical ventilation with low tidal volume (VT) is challenging. This study evaluated the ability of carotid corrected flow time (FTc) assessed by ultrasound for predicting the fluid responsiveness during low VT ventilation. Patients under postoperative mechanical ventilation and clinically diagnosed with hypovolemia were enrolled. Carotid FTc and pulse pressure variation (PPV) were measured at VT of 6 and 10 mL/kg predicted body weight (PBW). FTc was calculated using both Bazett’s (FTcB) and Wodey’s (FTcW) formulas. Fluid responsiveness was defined as a ≥15% increase in the stroke volume index assessed by FloTrac/Vigileo monitor after administration of 8 mL/kg of balanced crystalloid. Among 36 patients, 16 (44.4%) were fluid responders. The areas under the receiver operating characteristic curves (AUROCs) for the FTcB at VT of 6 and 10 mL/kg PBW were 0.897 (95% confidence interval [95% CI]: 0.750–0.973) and 0.895 (95% CI: 0.748–0.972), respectively. The AUROCs for the FTcW at VT of 6 and 10 mL/kg PBW were 0.875 (95% CI: 0.722–0.961) and 0.891 (95% CI: 0.744–0.970), respectively. However, PPV at VT of 6 mL/kg PBW (AUROC: 0.714, 95% CI: 0.539–0.852) showed significantly lower accuracy than that of PPV at VT of 10 mL/kg PBW (AUROC: 0.867, 95% CI: 0.712–0.957; p = 0.034). Carotid FTc can predict fluid responsiveness better than PPV during low VT ventilation. However, further studies using automated continuous monitoring system are needed before its clinical use.
Emergence agitation is common after septorhinoplasty, and postoperative pain is the main risk factor for this condition. Infraorbital and infratrochlear nerve block have been reported to facilitate pain management in patients after nasal procedures. The effect of peripheral nerve block on the incidence of emergence agitation has not been evaluated. Sixty-six patients that were scheduled for septorhinoplasty were assigned to receive bilateral infraorbital and infratrochlear nerve block with either 8 mL of 0.5% ropivacaine (Block group) or isotonic saline (Sham Block group). The incidence of emergence agitation was evaluated using the Riker sedation-agitation scale. Analgesic consumption, hemodynamic parameters, postoperative pain scores, adverse events, and patient satisfaction with analgesia were evaluated. The incidence of emergence agitation was lower in the Block group than in the Sham Block group (6 (20.0%) versus 20 (62.5%), p = 0.002). The mean intraoperative remifentanil consumption was lower in the Block group than in the Sham Block group (0.074 ± 0.014 μg/kg/min. versus 0.093 ± 0.019 μg/kg/min., respectively, p < 0.0001), as was the proportion of patients that needed postoperative tramadol administration and median postoperative pain score at 0–2 h after surgery (9 (30.0%) versus 21 (65.6%), p = 0.011; 3.0 (2.0–4.0) versus 4.0 (3.0–4.0), p < 0.0001, respectively). Hemodynamic parameters and the incidence of adverse events were similar between the two groups. The median patient satisfaction score with respect to analgesia was higher in the Block group than in the Sham Block group (3.5 (3.0–4.0) versus 3.0 (3.0–4.0), respectively, p = 0.034). The preoperative bilateral infraorbital and infratrochlear nerve block decreased the incidence of emergence agitation after septorhinoplasty.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.