Background and Objectives: The treatment of proximal humerus fractures in elderly patients is challenging, with reported high complication rates mostly related to implant failure involving screw cut-out and penetration. Metaphyseal defects are common in osteoporotic bone and weaken the osteosynthesis construct. A novel technique for augmentation with polymethylmethacrylate (PMMA) bone cement was developed for the treatment of patients in advanced age with complex proximal humerus fractures and metaphyseal voids, whereby the cement was allowed to partially cure for 5–7 min after mixing to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window with a volume of 4–6 mL per patient. The aim of this retrospective clinical study was to assess this technique versus autologous bone graft augmentation and no augmentation. Materials and Methods: The outcomes of 120 patients with plated Neer three- and four-part fractures, assigned to groups of 63 cases with no augmentation, 28 with bone graft augmentation and 29 with cement augmentation, were assessed in this study. DASH, CS, pain scores and range of motion were analyzed at 3, 6 and 12 months. Statistical analysis was performed with factors for treatment and age groups, Neer fracture types and follow-up periods, and with the consideration of age as a covariate. Results: DASH and CS improved following cement augmentation at three and six months compared to bone grafting, being significant when correcting for age as a covariate (p ≤ 0.007). While the age group had a significant effect on both these scores with worsened values at a higher age for non-augmented and grafted patients (p ≤ 0.044), this was not the case for cement augmented patients (p ≥ 0.128). Cement augmentation demonstrated good clinical results at 12 months with a mean DASH of 10.21 and mean CS percentage of 84.83% versus the contralateral side, not being significantly different among the techniques (p ≥ 0.372), despite the cement augmented group representing the older population with more four-part fractures. There were no concerning adverse events specifically related to the novel technique. Conclusions: This study has detailed a novel technique for the treatment of metaphyseal defects with PMMA cement augmentation in elderly patients with complex proximal humerus fractures and follow-up to one year, whereby the cement was allowed to partially cure to achieve medium viscosity, and then it was manually placed into the defect through the traumatic lateral window. The results demonstrate clinically equivalent short-term results to 6 months compared to augmentation with bone graft or no augmentation—despite the patient group being older and with a higher rate of more severe fracture patterns. The technique appears to be safe with no specifically related adverse events and can be added in the surgeon’s armamentarium for the treatment of these difficult to manage fractures.
Background and Objectives: Using 3D printed models in orthopaedics and traumatology contributes to a better understanding of injury patterns regarding surgical approaches, reduction techniques, and fracture fixation methods. The aim of this study is to evaluate the effectiveness of a novel technique implementing 3D printed models to facilitate the optimal preoperative planning of the surgical treatment of complex acetabular fractures. Materials and Methods: Patients with complex acetabular fractures were assigned to two groups: (1) conventional group (n = 12) and (2) 3D printed group (n = 10). Both groups included participants with either a posterior column plus posterior wall fracture, a transverse plus posterior wall fracture, or a both-column acetabular fracture. Datasets from CT scanning were segmented and converted to STL format, with separated bones and fragments for 3D printing in different colors. Comparison between the two groups was performed in terms of quality of fracture reduction (good: equal to, or less than 2 mm displacement, and fair: larger than 2 mm displacement), functional assessment, operative time, blood loss, and number of intraoperative x-rays. Results: A significant decrease in operative time, blood loss, and number of intraoperative x-rays was registered in the 3D printed group versus the conventional one (p < 0.01), with 80% of the patients in the former having good fracture reduction and 20% having fair reduction. In contrast, 50% of the patients in the conventional group had good reduction and 50% had fair reduction. The functional score at 18-month follow-up was better for patients in the 3D printed group. Conclusions: The 3D printing technique can be considered a highly efficient and patient-specific approach for management of complex acetabular fractures, helping to restore patient′s individual anatomy after surgery.
Reverse total shoulder arthroplasty (RTSA) has established itself as the standard of care for the treatment of rotator cuff arthropathy (RCA). Gradually, its share increased in relation to all used shoulder arthroplasties mainly in cases of complex proximal humeral fractures (PHFx). Method: From November 2019 to December 2021, 39 patients at mean age of 72.8 years were operated via RTSA Delta Xtend by one surgeon in our clinic. 32 of them were followed for a period between 12 ÷ 30 months. At postoperative visits, function and pain were assessed using the Constant-Murley score (CMS), DASH score and recorded range of motion (ROM). Level of satisfaction was assessed using the visual analogue scale (VAS). Results: The mean CMS recorded at the last visit was 82.6, and the relative one 90.8%. The achieved anterior elevation 145.9° and lateral elevation 136.6°. A significantly lower mean value of external rotation (39.8°) was found compared to the inner one (50.6°). Conclusion: This study confirms those described by other authors promising early results with Delta Xtend RTSA. Longer follow-up is needed with a view to assessment of the dynamics of registered results, possible late complications and revision interventions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.