The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.
The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.
Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.
The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.
e12068 Background: Randomized trials in Stage 0-II breast cancer have proven that APBI given via HDR implant in 5 days is equivalent to whole breast External Radiation Therapy (XRT) given in 5-6 weeks in regard to breast tumor local recurrence (LR). However, complications have been significant. Recently APBI using non-invasive IMRT given in 5 fractions has been shown in another randomized trial to be equivalent to XRT in 6 weeks, with respect to LR. IMRT was superior in regard to acute effects, late effects, and cosmesis. In the randomized clinical trial of APBI IMRT, the Clinical Target Volume (CTV) was defined by the injection of individual fiducial markers bordering the surgical cavity. At our institution, we have used the Biozorb fiducial system to localize the CTV for IMRT. We sought to confirm the APBI IMRT results with this simpler less labor intensive fiducial placement system. Methods: Between 2017 and 2019, 57 patients have undergone IMRT targeted to a Biozorb defined CTV with the walls of the surgical cavity sewn to the Biozorb device. Eligible patients were older than age 40, had tumor sizes ≤ 3 cm, negative surgical margins, and negative sentinel node dissections. IMRT dose was 30 Gy given in 5 fractions. Dose Constraints were as follows : V-30 Gy < 105%, Ipsilateral Breast V-15 Gy < 50%, Ipsilateral Lung V-10 Gy < 20%, Contralateral Lung V-5 Gy < 10%, Heart V-3 Gy < 20%, Contralateral Breast Dmax < 2 Gy and Skin Dmax < 27 Gy. The Planning Target Volume (PTV) ranged from 27 to 355 cc with a median of 80 cc. PTV = CTV + 1-2 cm. Results: Follow-up ranged from 1-14 months with a median of 7 months. LR has been 0% (0/57). There were no skin reactions. One patient developed pain around the Biozorb site. This resolved within 2 days on a short course of steroids. Cosmetic results as rated by the Surgeon, Radiation Oncologist, and Nurse, were rated excellent in 100% (57/57) of cases. Conclusions: Non-invasive APBI with IMRT targeted to Biozorb has resulted in LR, complications, and cosmetic results which compare favorably to invasive APBI given with HDR implant. At last follow-up, there have been no LR, skin reactions, or complications. Cosmesis has been excellent in 100% of patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.