These results demonstrate that method of administration (bolus vs. infusion), but not EDTA, influences the pharmacokinetics of propofol. Within the clinically relevant range, the kinetics of propofol during infusions are linear regarding infusion rate.
Semilinear canonical correlation defined a new measure of propofol effect on the EEG, the canonical univariate parameter for propofol. Using this parameter, propofol plasma effect-site equilibration is faster than previously reported. This fast onset was confirmed by inspection of the EEG data. Elderly patients are more sensitive to the hypnotic and EEG effects of propofol than are younger persons.
This study identified (1) an effect of age on the pharmacokinetics and pharmacodynamics of remifentanil; (2) an effect of lean body mass on the pharmacokinetic parameters; and (3) no influence of gender on any pharmacokinetic or pharmacodynamic parameter.
Based on the EEG model, age and LBM are significant demographic factors that must be considered when determining a dosage regimen for remifentanil. This remains true even when interindividual pharmacokinetic and pharmacodynamic variability are incorporated in the analysis.
Current measures of the performance of computer-controlled infusion pumps (CCIPs) are poorly defined, of little use to the clinician using the CCIP, and pharmacostatistically incorrect. We propose four measures be used to quantitate the performance of CCIPs: median absolute performance error (MDAPE), median performance error (MDPE), divergence, and wobble. These measures offer several significant advantages over previous measures. First, their definitions are based on the performance error as a fraction of the predicted (rather than measured) drug concentration, making the measures much more useful to the clinician. Second, the measures are defined in a way that addresses the pharmacostatistical issue of appropriate estimation of population parameters. Finally, the measure of inaccuracy, MDAPE, is defined in a way that is consistent with iteratively reweighted least squares nonlinear regression, a commonly used method of estimating pharmacokinetic parameters. These measures make it possible to quantitate the overall performance of a CCIP or to compare the predictive performance of CCIPs which differ in either general approach (e.g., compartmental model driven vs. plasma efflux approach), pump mechanics, software algorithms, or pharmacokinetic parameter sets.
Response surfaces can describe anesthetic interactions, even those between agonists, partial agonists, competitive antagonists, and inverse agonists. Application of response-surface methodology permits characterization of the full concentration-response relation and therefore can be used to develop practical guidelines for optimal drug dosing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.