A transmission x-ray absorption spectroscopy cell that can be used for air-sensitive samples with in situ treatment is described. The cell is designed with a relatively small size for use with air-sensitive powdered catalyst samples that must be loaded in a glove box. Samples can be treated in situ with gas flow or vacuum and temperature control up to 500 °C. The cell is constructed of stainless steel and designed for durability as well as ease of repair. The cells are vacuum tight and equipped with beryllium windows sealed with vacuum O-ring flanges for easy loading. Each cell, with all parts excluding the windows, costs about $2700.
The purpose of this study was to investigate the relationships of four intensities of tactile-thermal application (TTA) to changes in duration of stage transition (DST) and performance on a newly designed scale of penetration and aspiration by groups of patients made dysphagic by stroke. Patients were randomly assigned to receive 150, 300, 450, or 600 trials of TTA during each of 2 weeks. Data on the time required to provide such treatment, the actual number of trials clinicians were able to provide, and on the influence of the four intensities are provided. No single intensity emerged as the most therapeutic. It is suggested that subsequent studies with larger groups include intensities between 300 and 550.
The number of pediatric patients requiring some form of mechanical circulatory assistance is growing throughout the world because of new surgical procedures and the success of pediatric cardiac transplantation. However, the salvage rate for those patients requiring circulatory support may be as low as 25%. Despite the fact that Penn State's 70 cc pneumatic ventricular assist device has been used with a success rate of over 90% in more than 250 patients worldwide, efforts to scale down the pump have encountered difficulties. Animal experiments with a 15 cc version were unsuccessful, with explanted pumps showing extensive thrombus deposition within the pumping chamber. The materials used to fabricate the smaller pump as well as the basic operating principles are identical to the successful adult-sized version. It is therefore believed that reducing the size of the pump altered the internal flow field, and that fluid dynamic factors were responsible for the high degree of thrombus observed with the implanted devices. A dimensional analysis was conducted that revealed significant differences in both Reynolds (Re) and Strouhal (St) numbers between the successful and unsuccessful pumps. Two component laser Doppler velocimetry was then used to characterize the internal flow field quantitatively. Comparison with data from the 70 cc pump showed a reduction in wall shear stress and turbulence levels in the 15 cc pump that would yield an environment conducive to clot formation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.