Dynamic MR imaging applications often require compromises in spatial and/or temporal resolution when standard reconstruction schemes are used. Acquisition windows are limited by the passage of contrast agents, as with hyperpolarized nuclei and contrast enhanced angiography, and/or clinical feasibility, as in 3D cine flow imaging. Recently, several alternative sampling and reconstruction methods have been introduced that explore data redundancies in such applications. These methods include model-based reconstructions (1-3) that rely on a priori information and compressed sensing methods (4,5), which aim to reduce the number of k-space points to represent a given object.Recently, HighlY constrained backPRojection (HYPR) (3) reconstruction has been used in conjunction with undersampled radial acquisitions to permit radial undersampling factors of up to 80 in 2D and 1000 in 3D (6 -8) in selected time-resolved applications in which the images are sparse and have a high degree of spatiotemporal correlation. Unlike other acceleration methods, where signalto-noise ratio (SNR) tends to decrease in proportion to the square root of the acceleration factor, HYPR maintains SNR from the composite image used to constrain the unfiltered backprojection process. While originally formulated for angiography, HYPR has been applied to a wide range of imaging methods including hyperpolarized gas imaging, cerebral diffusion, and cine phase contrast, all of which have temporal information that is spatially correlated.In the original HYPR method, a series of radial acquisitions with interleaved k-space projection sets is acquired. Using 1D discrete Fourier transform, we obtain image space profiles P t i , i ϭ 1…N p , where N p is the number of projections acquired at each timeframe. Each of these Radon projections is then normalized by the corresponding Radon projections P c i , i ϭ 1…N p , of the composite image I c that is reconstructed by conventional methods from the projections in several or all of the acquired timeframes. An unfiltered backprojection operator B is applied to each normalized projection. The average of all the backprojected information for each timeframe may be regarded as a weighting image I w . The individual timeframe weighting images provide dynamic information. The final HYPR images I H are obtained by multiplication of the individual timeframe weighting images with the composite image, and can be described as:In the limit of extremely sparse images or images with complete spatiotemporal correlation the HYPR algorithm provides near exact reconstruction. However, as the sparsity and spatiotemporal correlation deteriorate, there can be crosstalk of signals from different portions of the imaging volume. This crosstalk has generally forced the use of narrow sliding window composites to improve waveform fidelity. Since the sliding window composite has fewer projections, it has more artifact than a full-length composite would. A HYPR-based method presented here uses the concept of local reconstruction (HYPR LR) by con...
BACKGROUND AND PURPOSE We have developed PC HYPRFlow, a comprehensive MRA technique that includes a whole-brain CE dynamic series followed by PC velocity-encoding, yielding a time series of high-resolution morphologic angiograms with associated velocity information. In this study, we present velocity data acquired by using the PC component of PC HYPRFlow (PC-VIPR). MATERIALS AND METHODS Ten healthy volunteers (6 women, 4 men) were scanned by using PC HYPRFlow and 2D-PC imaging, immediately followed by velocity measurements by using TCD. Velocity measurements were made in the M1 segments of the MCAs from the PC-VIPR, 2D-PC, and TCD examinations. RESULTS PC-VIPR showed approximately 30% lower mean velocity compared with TCD, consistent with other comparisons of TCD with PC-MRA. The correlation with TCD was r = 0.793, and the correlation of PC-VIPR with 2D-PC was r = 0.723. CONCLUSIONS PC-VIPR is a technique capable of acquiring high-resolution MRA of diagnostic quality with velocity data comparable with TCD and 2D-PC. The combination of velocity information and fast high-resolution whole-brain morphologic angiograms makes PC HYPRFlow an attractive alternative to current MRA methods.
BACKGROUND AND PURPOSE: Arteriovenous malformations have a high lifetime risk of hemorrhage; however, treatment carries a significant risk of morbidity and mortality, including permanent neurologic sequelae. WSS and other hemodynamic parameters are altered in patients with symptomatic AVMs, and analysis of hemodynamics may have value in stratifying patients into different risk groups. In this study, we examined hemodynamic data from patients with stable symptoms and those who presented with acute symptoms to identify trends which may help in risk stratification. MATERIALS AND METHODS: Phase-contrast MRA using a radial readout (PC-VIPR) is a fast, high-resolution technique that can acquire whole-brain velocity-encoded angiograms with scan times of approximately 5 minutes. Ten patients with AVMs were scanned using PC-VIPR; velocity, area, flow, and WSS in vessels feeding the AVMs and normal contralateral vessels were calculated using velocity data from the phase-contrast acquisition. RESULTS: Patients with an asymptomatic presentation or mild symptoms (n = 4) had no significant difference in WSS in feeding vessels compared with normal contralateral vessels, whereas patients presenting with hemorrhage, severe headaches/seizures, or focal neurologic deficits (n = 6) had significantly higher WSS in feeding vessels compared with contralateral vessels. CONCLUSIONS: In this study, we demonstrate that estimates of WSS and other hemodynamic parameters can be obtained noninvasively in patients with AVMs in clinically useful imaging times. Variation in WSS between feeders and normal vessels appears to relate to the clinical presentation of the patient. Further analysis of hemodynamic changes may improve characterization and staging of AVM patients, when combined with existing risk factors.
Purpose To develop and validate a novel free-breathing three-dimensional radial late Gadolinium-enhanced magnetic resonance imaging technique (3D LGE-MRI) with isotropic resolution and retrospective inversion time (TI) selection for myocardial viability imaging. Materials and Methods The 3D LGE-MRI featuring an interleaved and bit-reversed radial k-space trajectory was evaluated in twelve subjects that also had clinical breathhold Cartesian 2D LGE-MRI. The 3D LGE-MRI acquisition requires a predicted TI and a user controlled data acquisition window that determines the sampling width around the predicted TI. Sliding window reconstructions with update rates of 1x the repetition time (TR) allow for a user selectable TI to obtain the maximum nulling of the myocardium. The retrospective nature of the acquisition allows the user to choose from a range of possible TI times centered on the expected TI. Those projections most corrupted by respiratory motion, as determined by a respiratory bellows signal, were re-sampled according to the diminishing variance algorithm. The quality of the left ventricular myocardial nulling on the 3D LGE-MRI and 2D LGE-MRI was assessed using a 4-point Likert scale by two experienced radiologists. Comparison of image quality scores for the two methods was performed using generalized estimating equations. Results All 3D LGE-MRI cases produced similar nulling of myocardial signal as the 2D LGE-MRI. The image quality of myocardial nulling was not significantly different between the two acquisitions (mean nulling of 3.4 for 2D vs. 3.1 for 3D, and p=0.0645). The average absolute deviation from mean scores was also not determined to be statistically significant (1.8 for 2D and 0.4 for 3D and p = 0.1673). Total acquisition time was approximately 9 minutes for 3D LGE-MRI with voxel sizes ranging from 1.63 to 2.03 mm3. Conversely, the total imaging time was twice as long for the 2D DCE-MRI (>17 minutes) with an eight times larger voxel size of 1.4 mm × 2.2 mm × 7.0 mm. Conclusion The 3D LGE-MRI technique demonstrated in this study is a promising alternative for the assessment of myocardial viability in patients that have difficulty sustaining breath holds for the clinical standard 2D LGE-MRI.
Introduction White matter (WM) degeneration is a critical component of early Alzheimer's disease (AD) pathophysiology. Diffusion‐weighted imaging (DWI) models, including diffusion tensor imaging (DTI), neurite orientation dispersion and density imaging (NODDI), and mean apparent propagator MRI (MAP‐MRI), have the potential to identify early neurodegenerative WM changes associated with AD. Methods We imaged 213 (198 cognitively unimpaired) aging adults with DWI and used tract‐based spatial statistics to compare 15 DWI metrics of WM microstructure to 9 cerebrospinal fluid (CSF) markers of AD pathology and neurodegeneration treated as continuous variables. Results We found widespread WM injury in AD, as indexed by robust associations between DWI metrics and CSF biomarkers. MAP‐MRI had more spatially diffuse relationships with Aβ 42/40 and pTau, compared with NODDI and DTI. Discussion Our results suggest that WM degeneration may be more pervasive in AD than is commonly appreciated and that innovative DWI models such as MAP‐MRI may provide clinically viable biomarkers of AD‐related neurodegeneration in the earliest stages of AD progression.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.