A novel one-step protocol for the preparation of sub-micron magnetic particles as small as 30 nm in diameter has been developed. The surface of the particles was functionalized with carboxyl groups ( approximately 1 COOH per 15A2) to facilitate the attachment of affinity ligands. The high surface area of the resulting beads, combined with the high density of functional groups on the surface, makes them ideally suited for the preparative purification of proteins as was demonstrated by the efficient isolation of trypsin (36 mg per gram of particles) from pancreatic extract.
A novel one‐step protocol for the preparation of sub‐micron magnetic particles as small as 30 nm in diameter has been developed. The surface of the particles was functionalized with carboxyl groups (∼1 COOH per 15Å2) to facilitate the attachment of affinity ligands. The high surface area of the resulting beads, combined with the high density of functional groups on the surface, makes them ideally suited for the preparative purification of proteins as was demonstrated by the efficient isolation of trypsin (36 mg per gram of particles) from pancreatic extract. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 60: 419–424, 1998.
Two methods were used to compare the biodegradation of six polychlorinated biphenyl (PCB) congeners by 12 white rot fungi. Four fungi were found to be more active than Phanerochaete chrysosporium ATCC 24725. Biodegradation of the following congeners was monitored by gas chromatography: 2,3-dichlorobiphenyl, 4,4′-dichlorobiphenyl, 2,4′,5-trichlorobiphenyl (2,4′,5-TCB), 2,2′,4,4′-tetrachlorobiphenyl, 2,2′,5,5′-tetrachlorobiphenyl, and 2,2′,4,4′,5,5′-hexachlorobiphenyl. The congener tested for mineralization was 2,4′,5-[U-14C]TCB. Culture supernatants were also assayed for lignin peroxidase and manganese peroxidase activities. Of the fungi tested, two strains ofBjerkandera adusta (UAMH 8258 and UAMH 7308), one strain ofPleurotus ostreatus (UAMH 7964), and Trametes versicolor UAMH 8272 gave the highest biodegradation and mineralization. P. chrysosporium ATCC 24725, a strain frequently used in studies of PCB degradation, gave the lowest mineralization and biodegradation activities of the 12 fungi reported here. Low but detectable levels of lignin peroxidase and manganese peroxidase activity were present in culture supernatants, but no correlation was observed among any combination of PCB congener biodegradation, mineralization, and lignin peroxidase or manganese peroxidase activity. With the exception of P. chrysosporium, congener loss ranged from 40 to 96%; however, these values varied due to nonspecific congener binding to fungal biomass and glassware. Mineralization was much lower, ≤11%, because it measures a complete oxidation of at least part of the congener molecule but the results were more consistent and therefore more reliable in assessment of PCB biodegradation.
Quantitative NMR spectroscopy (qNMR) has been examined for purity assessment using a range of organic calibration standards of varying structural complexities, certified using the traditional mass balance approach. Demonstrated equivalence between the two independent purity values confirmed the accuracy of qNMR and highlighted the benefit of using both methods in tandem to minimise the potential for hidden bias, thereby conferring greater confidence in the overall purity assessment. A comprehensive approach to purity assessment is detailed, utilising, where appropriate, multiple peaks in the qNMR spectrum, chosen on the basis of scientific reason and statistical analysis. Two examples are presented in which differences between the purity assignment by qNMR and mass balance are addressed in different ways depending on the requirement of the end user, affording fit-for-purpose calibration standards in a cost-effective manner.
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM K55.b, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2010/2011. Nineteen national measurement institutes and the BIPM participated. Participants were required to assign the mass fraction of aldrin present as the main component in the comparison sample for CCQM-K55.b which consisted of technical grade aldrin obtained from the National Measurement Institute Australia that had been subject to serial recrystallization and drying prior to sub-division into the units supplied for the comparison.Aldrin was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molar mass range 300 Da to 500 Da] and low polarity (pKOW < −2) for which related structure impurities can be quantified by capillary gas phase chromatography (GC).The key comparison reference value (KCRV) for the aldrin content of the material was 950.8 mg/g with a combined standard uncertainty of 0.85 mg/g. The KCRV was assigned by combination of KCRVs assigned by consensus from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 0.3% to 0.6% using a mass balance approach and 0.5% to 1% using a qNMR method.The major analytical challenge posed by the material proved to be the detection and quantification of a significant amount of oligomeric organic material within the sample and most participants relying on a mass balance approach displayed a positive bias relative to the KCRV (overestimation of aldrin content) in excess of 10 mg/g due to not having adequate procedures in place to detect and quantify the non-volatile content—specifically the non-volatile organics content—of the comparison sample.There was in general excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content and the residual solvent content of the sample.The comparison demonstrated the utility of 1H NMR as an independent method for quantitative analysis of high purity compounds. In discussion of the participant results it was noted that while several had access to qNMR estimates for the aldrin content that were inconsistent with their mass balance determination they decided to accept the mass balance result and assumed a hidden bias in their NMR data. By contrast, laboratories that placed greater confidence in their qNMR result were able to resolve the discrepancy through additional studies that provided evidence of the presence of non-volatile organic impurity at the requisite level to bring their mass balance and qNMR estimates into agreement.Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.