Twenty-three patients who believed they suffered from food allergy were studied at the time of their presentation to an allergy clinic. The presence of organic food hypersensitivity could not be confirmed in 19 who attributed common neurotic symptoms to allergy; this group was almost identical, in terms of psychiatric symptomatology and general characteristics, with a group of new psychiatric out-patient referrals. There was no evidence of psychiatric disorder of food-related psychological symptoms in four patients with proven food-related atopic symptoms. The study failed to find evidence that psychological symptoms might be the result of organic reactions to foods.
Cardiac baroreceptor sensitivity, a prognostic indicator for a range of diseases, such as myocardial infarction and stroke, may be estimated from spontaneous fluctuations of arterial blood pressure (BP) and heart rate using sequence analysis. We tested the hypothesis that BP values recorded with the non-invasive Finapres device do not always produce sequences coincident with sequences detected from central BP measurements. Finapres recordings of resting BP in the finger, ascending aorta (Millar catheter-tip transducer) and ECG were obtained from 34 patients undergoing coronary angioplasty, including 24 patients treated with betablockers. Coincidence of baroreflex sensitivity (BRS) sequences was expressed by the sensitivity of the Finapres to detect a simultaneously occurring sequence in aortic pressure. The influence of different criteria to detect and accept sequences from beat-to-beat values of systolic BP (SBP) and cardiac interval (RRi) on the Finapres sensitivity was also assessed. The Finapres was able to detect 70.7% of all three beat intra-arterial sequences when the selection criteria was based on the correlation coefficient between SBP and RRi (>0.85), but decreased to 27.5% when the P-value of the linear regression was limited to 0.05. Changing the thresholds for minimum changes in SBP and RRi also had significant effects on sensitivity, as well as in the corresponding values of BRS. Significant differences in BRS were obtained between invasive and non-invasive estimates, but there was no difference between non-invasive estimates calculated from coincident and non-coincident sequences. Non-invasive, compared with intra-arterial estimates of BRS by sequence analysis are not influenced by coincidence of sequences if acceptance of sequences is based on the correlation coefficient criteria (>0.85).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.