In acute lung injury (ALI), pressure support ventilation (PSV) may improve oxygenation compared with pressure-controlled ventilation (PCV), and benefit from random variation of pressure support (noisy PSV). We investigated the effects of PCV, PSV, and noisy PSV on gas exchange as well as the distribution of lung aeration and perfusion in 12 pigs with ALI induced by saline lung lavage in supine position. After injury, animals were mechanically ventilated with PCV, PSV, and noisy PSV for 1 h/mode in random sequence. The driving pressure was set to a mean tidal volume of 6 ml/kg and positive end-expiratory pressure to 8 cmH₂O in all modes. Functional variables were measured, and the distribution of lung aeration was determined by static and dynamic computed tomography (CT), whereas the distribution of pulmonary blood flow (PBF) was determined by intravenously administered fluorescent microspheres. PSV and noisy PSV improved oxygenation and reduced venous admixture compared with PCV. Mechanical ventilation with PSV and noisy PSV did not decrease nonaerated areas but led to a redistribution of PBF from dorsal to ventral lung regions and reduced tidal reaeration and hyperinflation compared with PCV. Noisy PSV further improved oxygenation and redistributed PBF from caudal to cranial lung regions compared with conventional PSV. We conclude that assisted ventilation with PSV and noisy PSV improves oxygenation compared with PCV through redistribution of PBF from dependent to nondependent zones without lung recruitment. Random variation of pressure support further redistributes PBF and improves oxygenation compared with conventional PSV.
BackgroundHibernomas are rare benign soft-tissue tumours arising from brown fat tissue. Although imaging characteristics are not specific certain imaging features, common locations and patient demographics may suggest hibernoma as a differential diagnosis.Case presentationWe report on two 48-year-old male patients with hibernoma. The tumour presented with local swelling of the inguinal region in the first patient and was an incidental imaging finding in the second patient. Imaging included magnetic resonance imaging in both patients and computed tomography as well as 18 F-fluorodeoxyglucose positron emission tomography-computed tomography in the second patient. In both cases histological diagnosis was initially based on excisional and needle core biopsy, respectively. Complete surgical resection confirmed the diagnosis of hibernoma thereafter.ConclusionIn soft tissue tumours with fatty components hibernoma may be included into the differential diagnosis. Because of the risk of sampling errors in hibernoma-like tissue components of myxoid and well-differentiated liposarcoma, complete resection is mandatory. This article also reviews the current imaging literature of hibernomas.
Purpose: To estimate feasible dose reduction to reliably measure ventricular width in adults with hydrocephalus in follow-up cranial computed tomography (CCT) using a custom-made phantom. Materials and Methods: A gelatine-filled adult calvarium with embedded central fibers of two carrots representing the lateral ventricles was used as a phantom. The phantom was scanned 11 times with two CT scanners (LightSpeed Ultra, GE and Somatom Sensation, Siemens), using tube currents of 380/400, 350, 300, 250, 200, 150 and 100 mA, and tube voltages of 140, 120, 100 and 80?kV. The width of the carrots was measured at four sites in consensus decision of two principle investigators blinded to the scan parameters. Values measured at 380/400 mA and 140?kV served as a reference for the width of the ventricles. Measurements received 1 point if they did not differ more than 0.5?mm from the reference values. A maximum score of 4 could be achieved. Results: The relationship between the correct width measurement of the carrots (lateral ventricles) and the radiation dose can be described by a quadratic regression function. Pixel noise increases and accuracy of measurements decreases with a lower radiation dose. Starting from a tube current of 380/400 mA and a tube voltage of 140?kV, the dose can be reduced by 76?% for LightSpeed Ultra and by 80?% for Somatom Sensation provided that a margin of error of 37.5?% (score?=?2.5) for correct width measurement of the carrots is accepted. Conclusion: Lowering the radiation dose by up to 48?% for LightSpeed Ultra and by 52?% for Somatom Sensation, compared to the standard protocol (120?kV and 400 mA) still allowed reliable measurements of ventricular widths in this model. Key Points: ??There is a quadratic relationship between correct width measurements of lateral ventricles and radiation dose in CT. ??Reduction of radiation dose results in increased pixel noise and increased error for correct ventricle width measurement. ??Due to a considerable attenuation difference between cerebrospinal fluid and brain parenchyma, a dose reduction for the determination of ventricular size in CT seems feasible and should be performed. Citation Format: ??Daubner D, Spieth S, Cerhova J et?al. Measuring Ventricular Width on Cranial Computed Tomography: Feasibility of Dose?Reduction in a Custom-Made Adult Phantom. Fortschr R?ntgenstr 2016; 188: 73???81
Imaging of Graves' orbitopathy (GO) includes radiological and nuclear medicine procedures. Depending on the method used they provide information about the distribution and activity of the disease. Magnetic resonance imaging (MRI) is not only a helpful tool for making the diagnosis it also enables differentiation of the active and inactive forms of GO due to intramuscular edema. The modality is therefore appropriate to evaluate the disease activity and the course of therapy. The disease leads to the typical enlargement of the muscle bodies of the extraocular muscles. The inferior rectus, medial rectus and levator palpebrae muscles are mostly involved. Signal changes of the intraconal and extraconal fat tissue are possible and a bilateral manifestation is common. The differential diagnosis includes inflammatory diseases and tumors, of which orbital pseudotumor (idiopathic, unspecific orbital inflammation), ocular myositis and orbital lymphoma are the most important. The specific patterns (localization, involvement of orbital structures and signal changes) can be differentiated by MRI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.