Cell-free protein synthesis (CFPS) platforms, once primarily a research tool to produce difficult to express proteins, are increasingly being pursued by the synthetic biology community for applications including biomanufacturing, rapid screening systems, and field-ready sensors. While consistency within individual studies is apparent in the literature, challenges with reproducing results between laboratories, or even between individuals within a laboratory, are discussed openly by practitioners. As the field continues to grow and move toward applications, a quantitative understanding of expected variability for CFPS and the relative contribution of underlying sources will become increasingly important. Here we offer the first quantitative assessment of interlaboratory variability in CFPS. Three laboratories implemented a single CFPS protocol and performed a series of exchanges, both of material and personnel, designed to quantify relative contributions to variability associated with the site, operator, cell extract preparation, and supplemental reagent preparation. We found that materials prepared at each laboratory, exchanged pairwise, and tested at each site resulted in 40.3% coefficient of variation compared to 7.64% for a single operator across days using a single set of materials. Reagent preparations contributed significantly to observed variability; extract preparations, however, surprisingly did not explain any of the observed variability, even when prepared in different laboratories by different operators. Subsequent exchanges showed that both the site and the operator each contributed to observed interlaboratory variability. In addition to providing the first quantitative assessment of interlaboratory variability in CFPS, these results establish a baseline for individual operator variability across days that can be used as an initial benchmark for community-driven standardization efforts. We anticipate that our results will narrow future avenues of investigation to develop best practices that will ultimately drive down interlaboratory variability, accelerating research progress and informing the suitability of CFPS for real-world applications.
Cell-free systems that mimic essential cell functions, such as gene expression, have dramatically expanded in recent years, both in terms of applications and widespread adoption. Here we provide a review of cell-extract methods, with a specific focus on prokaryotic systems. Firstly, we describe the diversity of Escherichia coli genetic strains available and their corresponding utility. We then trace the history of cell-extract methodology over the past 20 years, showing key improvements that lower the entry level for new researchers. Next, we survey the rise of new prokaryotic cell-free systems, with associated methods, and the opportunities provided. Finally, we use this historical perspective to comment on the role of methodology improvements and highlight where further improvements may be possible.
Many bacterial mechanisms for highly specific and sensitive detection of heavy metals and other hazards have been reengineered to serve as sensors. In some cases, these sensors have been implemented in cell-free expression systems, enabling easier design optimization and deployment in low-resource settings through lyophilization. Here, we apply the advantages of cell-free expression systems to optimize sensors based on three separate bacterial response mechanisms for arsenic, cadmium, and mercury. We achieved detection limits below the World Health Organization-recommended levels for arsenic and mercury and below the short-term US Military Exposure Guideline levels for all three. The optimization of each sensor was approached differently, leading to observations useful for the development of future sensors: (1) there can be a strong dependence of specificity on the particular cell-free expression system used, (2) tuning of relative concentrations of the sensing and reporter elements improves sensitivity, and (3) sensor performance can vary significantly with linear vs plasmid DNA. In addition, we show that simply combining DNA for the three sensors into a single reaction enables detection of each target heavy metal without any further optimization. This combined approach could lead to sensors that detect a range of hazards at once, such as a panel of water contaminants or all known variants of a target virus. For low-resource settings, such "all-hazard" sensors in a cheap, easy-to-use format could have high utility.
Organophosphorus (OP) pesticides are known to induce pulmonary toxicity in both humans and experimental animals. To elucidate the mechanism of OP-induced cytotoxicity, we examined the effects of parathion and malathion and their respective metabolites, paraoxon and malaoxon, on primary cultured human large and small airway cells. Exposure to paraoxon and malaoxon produced a dose-dependent increase in cytotoxicity following a 24-hour exposure, while treatment with parathion or malathion produced no effects at clinically relevant concentrations. Exposure to paraoxon-induced caspase activation, but malaoxon failed to induce this response. Since caspases have a major role in the regulation of apoptosis and cell death, we evaluated OP-induced cell death in the presence of a caspase inhibitor. Pharmacological caspase inhibition protected against paraoxon-induced cell death but not malaoxon-induced cell death. These data suggest that caspase activation is a key signaling element in paraoxon-induced cell death, but not malaoxon-induced cellular death in the pulmonary epithelium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.