The use of intraaortic balloon counterpulsation did not significantly reduce 30-day mortality in patients with cardiogenic shock complicating acute myocardial infarction for whom an early revascularization strategy was planned. (Funded by the German Research Foundation and others; IABP-SHOCK II ClinicalTrials.gov number, NCT00491036.).
Among patients who had multivessel coronary artery disease and acute myocardial infarction with cardiogenic shock, the 30-day risk of a composite of death or severe renal failure leading to renal-replacement therapy was lower among those who initially underwent PCI of the culprit lesion only than among those who underwent immediate multivessel PCI. (Funded by the European Union 7th Framework Program and others; CULPRIT-SHOCK ClinicalTrials.gov number, NCT01927549 .).
Background—
The number of patients with longer follow-up after implantation of an implantable cardioverter-defibrillator is increasing continuously. Defibrillation lead failure is a typical long-term complication. Therefore, the long-term reliability of implantable cardioverter-defibrillator leads has become an increasing concern. The aim of the present study was to assess the annual rate of transvenous defibrillation lead defects related to follow-up time after lead implantation.
Methods and Results—
A total of 990 consecutive patients who underwent first implantation of an implantable cardioverter-defibrillator between 1992 and May 2005 were analyzed. Median follow-up time was 934 days (interquartile range, 368 to 1870). Overall, 148 defibrillation leads (15%) failed during the follow-up. The estimated lead survival rates at 5 and 8 years after implantation were 85% and 60%, respectively. The annual failure rate increased progressively with time after implantation and reached 20% in 10-year-old leads (
P
<0.001). Lead defects affected newer as well as older models. Patients with lead defects were 3 years younger at implantation and more often female. Multiple lead implantation was associated with a trend to a higher rate of defibrillation lead defects (
P
=0.06). The major lead complications were insulation defects (56%), lead fractures (12%), loss of ventricular capture (11%), abnormal lead impedance (10%), and sensing failure (10%).
Conclusions—
An increasing annual lead failure rate is noted primarily during long-term follow-up and reached 20% in 10-year-old leads. Patients with lead defects are younger and more often female.
MD; for the OMEGA Study GroupBackground-There is no randomized, double-blind trial testing the prognostic effect of highly purified omega-3 fatty acids in addition to current guideline-adjusted treatment of acute myocardial infarction. Methods and Results-OMEGA is a randomized, placebo-controlled, double-blind, multicenter trial testing the effects of omega-3-acid ethyl esters-90 (1 g/d for 1 year) on the rate of sudden cardiac death in survivors of acute myocardial infarction, if given in addition to current guideline-adjusted treatment. Secondary end points were total mortality and nonfatal clinical events. Patients (nϭ3851; female, 25.6%; mean age, 64.0 years) were randomized in 104 German centers 3 to 14 days after acute myocardial infarction from October 2003 until June 2007. Acute coronary angiography was performed in 93.8% and acute percutaneous coronary intervention in 77.8% of all patients. During a follow-up of 365 days, the event rates were (omega and control groups) as follows: sudden cardiac death, 1.5% and 1.5% (Pϭ0.84); total mortality, 4.6% and 3.7% (Pϭ0.18); major adverse cerebrovascular and cardiovascular events, 10.4% and 8.8% (Pϭ0.1); and revascularization in survivors, 27.6% and 29.1% (Pϭ0.34). Conclusions-Guideline-adjusted treatment of acute myocardial infarction results in a low rate of sudden cardiac death and other clinical events within 1 year of follow-up, which could not be shown to be further reduced by the application of omega-3 fatty acids. Clinical Trial Registration-URL: http://www.clinicaltrials.gov.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.