In recent years, methicillin-resistant Staphylococcus aureus (MRSA) have become a truly global challenge. In addition to the long-known healthcare-associated clones, novel strains have also emerged outside of the hospital settings, in the community as well as in livestock. The emergence and spread of virulent clones expressing Panton-Valentine leukocidin (PVL) is an additional cause for concern. In order to provide an overview of pandemic, epidemic and sporadic strains, more than 3,000 clinical and veterinary isolates of MRSA mainly from Germany, the United Kingdom, Ireland, France, Malta, Abu Dhabi, Hong Kong, Australia, Trinidad & Tobago as well as some reference strains from the United States have been genotyped by DNA microarray analysis. This technique allowed the assignment of the MRSA isolates to 34 distinct lineages which can be clearly defined based on non-mobile genes. The results were in accordance with data from multilocus sequence typing. More than 100 different strains were distinguished based on affiliation to these lineages, SCCmec type and the presence or absence of PVL. These strains are described here mainly with regard to clinically relevant antimicrobial resistance- and virulence-associated markers, but also in relation to epidemiology and geographic distribution. The findings of the study show a high level of biodiversity among MRSA, especially among strains harbouring SCCmec IV and V elements. The data also indicate a high rate of genetic recombination in MRSA involving SCC elements, bacteriophages or other mobile genetic elements and large-scale chromosomal replacements.
A diagnostic microarray was used to characterise a collection of methicillin-resistant Staphylococcus aureus (MRSA) isolates from hospitals in the German region of Eastern Saxony. The most abundant epidemic MRSA (EMRSA) strains were ST5-MRSA II (Rhine-Hesse EMRSA, EMRSA-3), CC5/ST228-MRSA I (South German EMRSA), ST22-MRSA IV (Barnim EMRSA, EMRSA-15) and ST45-MRSA IV (Berlin EMRSA). Other strains were found only as sporadic isolates or in minor outbreaks. These strains included ST1-MRSA IV, ST8-MRSA IV (Hannover EMRSA and others), clonal group 5 strains carrying SCCmec type IV elements (Paediatric clone), ST45-MRSA V, CC8/ST239-MRSA III and ST398-MRSA V. Panton-Valentine leukocidin-positive MRSA isolates were still very rare. The predominant strain was ST80-MRSA IV, although increasing numbers of different strains have recently been detected (ST8-MRSA IV, ST30-MRSA IV and ST59-MRSA V). For more common MRSA strains, it was possible to detect variants that differed mainly in the carriage of additional resistance determinants and certain virulence-associated genes. Detection of such variants can sometimes allow epidemic strains to be resolved beyond spa types to a hospital-specific level, which is of significant value for epidemiological purposes.
Early detection and adherence to infection prevention recommendations are necessary to avoid transmission.
Robotic drilling was conducted with an accuracy of 0.2 mm and safety mechanisms predicted proximity of the nerves to within 0.1 mm. The approach resulted in a minimal mastoidectomy and minimal incisions. Manual electrode array insertion was successfully performed through the robotically drilled tunnel. The procedure was performed without complications, and all surrounding structures were preserved.
Surgical robot systems can work beyond the limits of human perception, dexterity and scale making them inherently suitable for use in microsurgical procedures. However, despite extensive research, image-guided robotics applications for microsurgery have seen limited introduction into clinical care to date. Among others, challenges are geometric scale and haptic resolution at which the surgeon cannot sufficiently control a device outside the range of human faculties. Mechanisms are required to ascertain redundant control on process variables that ensure safety of the device, much like instrument-flight in avionics. Cochlear implantation surgery is a microsurgical procedure, in which specific tasks are at sub-millimetric scale and exceed reliable visuo-tactile feedback. Cochlear implantation is subject to intra- and inter-operative variations, leading to potentially inconsistent clinical and audiological outcomes for patients. The concept of robotic cochlear implantation aims to increase consistency of surgical outcomes such as preservation of residual hearing and reduce invasiveness of the procedure. We report successful image-guided, robotic CI in human. The robotic treatment model encompasses: computer-assisted surgery planning, precision stereotactic image-guidance, in-situ assessment of tissue properties and multipolar neuromonitoring (NM), all based on in vitro, in vivo and pilot data. The model is expandable to integrate additional robotic functionalities such as cochlear access and electrode insertion. Our results demonstrate the feasibility and possibilities of using robotic technology for microsurgery on the lateral skull base. It has the potential for benefit in other microsurgical domains for which there is no task-oriented, robotic technology available at present.
To establish the role of local transmission versus possible pathogen import due to previous foreign exposure in infections caused by carbapenem non-susceptible Enterobacteriaceae in the Arabian Peninsula, 200 independent isolates collected in 16 hospitals of Saudi Arabia, Kuwait, Oman and the United Arab Emirates were studied. All strains were multidrug resistant; 42.5% of them also qualified as extremely drug resistant. The frequency of various carbapenemases varied according to the participating countries, but in the collection, as a whole, bla NDM-1 was the most frequently encountered carbapenemase gene (46.5%) followed by bla OXA-48-like gene (32.5%). A comparatively high rate (8.9%) of multi-clonal strains carrying both bla NDM and bla OXA-48-like genes in the United Arab Emirates, representing the most resistant subgroup, was encountered. No KPC-expressing isolates were detected. Three major clones of bla NDM-1 carrying Klebsiella pneumoniae of ST152 (n = 22, Saudi Arabia), ST14 (n = 7, United Arab Emirates) and ST147 types (n = 9, Oman) were identified, the latter two clones carrying similar, but not identical HI1b incompatibility type plasmids of >170kb. While from 78.6% of the cases with documented foreign hospitalization bla NDM positive strains were isolated, these strains formed only 25.6% of all the isolates expressing this enzyme. In fact, 56.8% of the NDM, 75.7% of OXA-48-like and 90.9% of VIM positive strains were recovered from patients without documented foreign exposure, neither in the form of travel or prior hospitalization abroad, suggesting a high rate of autochthonous infections. This, considering the extensive links of these countries to the rest of the world, predicts that trends in the local epidemiology of carbapenem resistant strains may increasingly affect the spread of these pathogens on the global scale. These results call for improved surveillance of carbapenem resistant Enterobacteriaceae in the countries of the Arabian Peninsula.
The purpose-built robot system was able to perform a safe and reliable DCA for cochlear implantation. The workflow implemented in this study mimics the envisioned clinical procedure showing the feasibility of future clinical implementation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.