Mechanical or anatomical alignment techniques create a supposedly ‘biomechanically friendly’ but often functionally limited prosthetic knee.Alternative techniques for alignment in total knee arthroplasty (TKA) aim at being more anatomical and patient-specific, aiming to improve functional outcomes after TKA.The kinematic alignment (KA) technique for TKA has shown good early clinical outcomes. Its role in extreme anatomical variation remains to be defined.The restricted KA technique for TKA might be a reasonable option for patients with extreme anatomical variation.While unicompartmental knee arthroplasty (UKA) has many advantages over TKA, the revision rate remains higher compared with TKA. One major explanation is the relative ease with which a UKA can be converted to a TKA, compared with revising a TKA. This can be considered as an additional advantage of UKA. Another reason is that surgeons favour revising a UKA to a TKA in cases of degeneration of the other femorotibial compartment rather than performing a relatively simple re-operation of the knee by doing an additional UKA (staged bi-UKA).Cite this article: EFORT Open Rev 2018;3:1–6. DOI: 10.1302/2058-5241.3.170021
Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome.Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs.By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes.An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning.The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes.Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020
Multimodal protocols for pain control, blood loss management and thromboprophylaxis have been shown to benefit patients by being more effective and as safe (fewer iatrogenic complications) as conventional protocols.Proper patient selection and education, multimodal protocols and a well-defined clinical pathway are all key for successful day-case arthroplasty.By potentially being more effective, cheaper than and as safe as inpatient arthroplasty, day-case arthroplasty might be beneficial for patients and healthcare systems.Cite this article: EFORT Open Rev 2018;3:130-135. DOI: 10.1302/2058-5241.3.170031
Conventional techniques for hip and knee arthroplasty have led to good long-term clinical outcomes, but complications remain despite better surgical precision and improvements in implant design and quality.Technological improvements and a better understanding of joint kinematics have facilitated the progression to ‘personalized’ implant positioning (kinematic alignment) for total hip (THA) and knee (TKA) arthroplasty, the true value of which remains to be determined.By achieving a true knee resurfacing, the kinematic alignment (KA) technique for TKA aims at aligning the components with the physiological kinematic axes of the knee and restoring the constitutional tibio-femoral joint line frontal and axial orientation and soft-tissue laxity.The KA technique for THA aims at restoring the native ‘combined femoro-acetabular anteversion’ and the hip’s centre of rotation, and occasionally adjusting the cup position and design based on the assessment of the individual spine-hip relation.The key element for optimal prosthetic joint kinematics (hip or knee) is to reproduce the femoral anatomy.The transverse acetabular ligament (TAL) is the reference landmark to adjust the cup position.Cite this article: EFORT Open Rev 2018;3:98-105. DOI: 10.1302/2058-5241.3.170022
Background: Osteoarthritis (OA) of the knee is a chronic, progressive condition which often requires
Introduction: Hip fractures are an important cause of morbidity and mortality. Early surgery has been shown to reduce mortality rates and surgical complications. The American Society of Anesthesiologists (ASA) grade is a widely used tool to assess preoperative health of patients. This study aims to assess is whether delay in surgical time has a greater impact on the mortality rates for high risk patients. Method: Retrospective study using the National Hip Fracture Database (NHFD) of 4883 neck of femur fracture patients. Time of surgery, ASA grade, reason for delay and mortality at 120 days was analysed, using statistical analysis software. Results: There was a significant increase in mortality ( p < 0.001) with increasing ASA grade. Surgical delays of more than 36 hours increased mortality by 2.9%. The impact of delaying surgery became more pronounced as the ASA grade increased. ASA 3 and above had an optimum time to surgery of between 12 and 24 hours giving the statistically significant lowest mortality rate ( p = 0.004). Discussion: Surgical delay beyond the 36-hour target for surgery has a greater impact on mortality for patients with higher ASA grades. The effect is most profound in the high-risk ASA grade 5 patients with delayed patients showing a 37.5% increase in mortality in this group. This would imply that by prioritising this higher risk group and operating on it within a specific time frame there would be a subsequent fall in mortality associated with neck of femur fractures.
Background: Polycarbonate urethane (PCU) is a bearing surface with a lower modulus of elasticity than polyethylene or ceramic and is thought to more closely replicate the tribology of native hyaline cartilage. The purpose of this study was to determine the clinical outcomes with the use of PCU in elective total hip arthroplasty (THA). Methods: We carried out a prospective observational study in which 157 patients underwent elective THA with a metal-on-PCU hip system. Patients had radiographic follow-up at 6 months and 3 years after surgery. Oxford Hip Scores and EuroQol scores were obtained annually and Harris Hip Scores were obtained at 6 months and 3 years after surgery. Results: 180 hips were implanted, of which, 149 hips reached 3-year review with no revisions. There was an increase in Harris Hip Scores, Oxford Hip Scores and EuroQol scores ( p < 0.001). 12 patients (12 hips) reported painless hip squeaking. There were no dislocations and no other adverse events were reported. Conclusion: Our results showed satisfactory survivorship and improvements in patient reported outcomes with metal on PCU THA. Long-term data are still being collected to confirm these findings. We recommend further tribological research into the squeaking phenomenon we observed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.