PurposeElectrical properties of biological tissues are known to be sensitive to physiological and pathological conditions of living organisms. For instance, human breast cancer or liver tumor cells have a significantly higher electrical conductivity than a healthy tissue. The paper aims to the new recently developed magnetoacoustic tomography with magnetic induction (MAT-MI) which can be deployed for electrical conductivity imaging of low-conductivity objects. Solving a test problem by using an analytical method is a useful exercise to check the validity of the more complex numerical finite element models. Such test problems are discussed in Chapter 3. The detailed analysis of an electromagnetic induction in low-conductivity objects is very important for the next steps in the tomographic process of image reconstruction. Finally, the image reconstruction examples for object’s complex shapes’ have been analyzed. The Lorentz force divergence reconstruction has been achieved with the help of time reversal algorithm.
Design/methodology/approachIn given arrangements the magnetic field and eddy current vectors satisfy the Maxwell partial differential equations. Applying the separation of variables method analytical solutions are obtained for an infinitely long conducting cylindrical segment in transient magnetic field. A special case for such a configuration is an infinitely long cylinder with longitudinal crack. The analytical solutions are compared with those obtained by using numerical procedures. For complex shapes of the object, the MAT-MI images have been calculated with the help of the finite element method and time reversal algorithm.
FindingsThe finite element model developed for a MAT-MI forward problem has been validated by analytical formulas. Based on such a confirmation, the MAT-MI complex model has been defined and solved. The conditions allowing successful MAT-MI image reconstruction have been provided taking into account different conductivity distribution. For given object’s parameters, the minimum number of measuring points allowing successful reconstruction has been determined.
Originality/valueA simple test example has been proposed for MAT-MI forward problem. Analytical closed-form solutions have been used to check the validity of the made in-house finite element software. More complex forward and inverse problems have been solved using the software.
Purpose -The purpose of this paper is to describe the full-wave modelling of pulsed terahertz systems utilized in non-destructive testing. Design/methodology/approach -At the outset, some basic information on the terahertz NDT are outlined and then, general remarks on its numerical modelling are presented. Frequency domain FEM and time domain FDTD analysis is carried out. Finally comparison of computed and measured signals is shown in order to prove numerical analysis correctness. Findings -It is possible to model in a relatively simple way a terahertz system for nondestructive evaluation of dielectric materials. In contrast to other published work, the entire measuring setup is modelled, including photoconductive antenna with hemispherical lens, focusing lens and evaluated material with exemplary defect. Originality/value -This paper gives a description of the terahertz non-destructive testing system with comparison of simulated and measured results.
The common strategy for reducing static and lowfrequency magnetic fields in a specific region consists of surrounding the volume of interest with a layer of material with high magnetic permeability. However, if for some reasons, ferromagnetic materials are undesirable, rotating conducting nonmagnetic screens could be applied. In this paper, we discuss such a possibility in a quantitative way. Analytical solutions are obtained for infinitely long cylindrical shells rotating in a uniform, static, and time-harmonic external magnetic field. Useful simplified expressions for the shielding factors are given. Numerical results are shown for screens of finite length.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.