Various powders of graphene oxide (GO), GO with silver (GO-Ag) and zinc oxide (GO-ZnO) were obtained. The powders were silanized with (3-aminopropyl) triethoxysilane (APTES) aiming to be used, in a future stage, as additives in the hydraulic lime mortars composition. The powders were characterized by Fourier Transform Infrared Spectrometry (FTIR) and Scanning Electron Microscopy (SEM) before and after the silanization process. GO, GO-Ag, GO-Ag-APTES, GO-ZnO and GO-ZnO-APTES powders were also investigated by Thermogravimetric Analysis (TG/DTA) and Ultraviolet–Visible Spectroscopy (UV-Vis). Likewise, the antibacterial effect of powders against five bacterial strains was evaluated. The peaks associated to the functional groups from GO, GO-APTES, GO-Ag, GO-Ag-APTES, GO-ZnO and GO-ZnO-APTES powders were identified by FTIR analysis. The mass losses of powders, analyzed by TG/DTA were lower than those recorded for GO. By UV-VIS analysis, maxima corresponding to the electronic π-π * and n-π * transitions were recorded. SEM images highlighted the lamellar and layered structure of GO, but also the presence of Ag and Zn nanoparticles on the surface of graphene sheets. All these results confirm the presence of Ag/ZnO/APTES on the GO. The antibacterial effect evaluated by recording the diameter of the inhibition zone ranged between 12–22 mm.
Dental light-curing giomers were developed to combine the favourable properties of diacrylic resin composites (DRCs) and glass-ionomer cements (GICs) in a single material and to eliminate their inherent drawbacks. Giomers are characterized by their aesthetic appearance, high mechanical properties, adhesion to dental tissues as well as fluoride release and recharge abilities. The qualities of the giomers are greatly influenced by the level of conversion of the component resins. Infrared spectroscopy is one of the most largely used techniques for the determination of the degree of conversion in resin-based dental materials. However different results were obtained due to the performances of the used methods. The present work presents the determination of conversion degree in a series of dental copolymers and their corresponding giomers using transmission Fourier transform infrared spectroscopy (FTIR) and an attenuated total reflection technique (ATR) technique, respectively, the main aim being the study of the influence of the materials composition and of the light curing modes upon the achieved conversion in the cured giomers. Beautifil II commercial giomer was used as a control. A halogen lamp and a diode-blue LED lamp were used for the curing of the materials. The results showed that the composition of the resins greatly influenced the conversion. The highest conversions (up to 79%) were obtained in the case of the experimental giomers which contained the experimental Bis-GMA urethane analogue, followed by the Beautifil II giomer (61%) and experimental giomers based on commercial Bis-GMA (up to 50%), respectively. The resins light-cured by using the diode-blue LED lamp presented slightly higher conversions than the resins cured by halogen lamp. The study demonstrates the possibility to evaluate easily and reproducibly the conversion in light-curing composite materials with complex chemical composition and structure, particularly in the case of giomers by using the ATR technique.
Brackets are metallic dental devices that are very often associated with acidic soft drinks such as cola and energy drinks. Acid erosion may affect the bonding between brackets and the enamel surface. The purpose of this study was to investigate the characteristics of brackets’ adhesion, in the presence of two different commercially available drinks. Sixty human teeth were divided into six groups and bonded with either resin-modified glass ionomer (RMGIC) or resin composite (CR). A shared bond test (SBS) was evaluated by comparing two control groups with four other categories, in which teeth were immersed in either Coca-ColaTM or Red BullTM energy drink. The debonding between the bracket and enamel was evaluated by SEM. The morphological aspect correlated with SBS results showed the best results for the samples exposed to artificial saliva. The best adhesion resistance to the acid erosion environment was observed in the group of teeth immersed in Red BullTM and with brackets bonded with RMGIC. The debonded structures were also exposed to Coca-ColaTM and Red BullTM to assess, by atomic force microscopy investigation (AFM), the erosive effect on the enamel surface after debonding and after polishing restoration. The results showed a significant increase in surface roughness due to acid erosion. Polishing restoration of the enamel surface significantly reduced the surface roughness that resulted after debonding, and inhibited acid erosion. The roughness values obtained from polished samples after exposure to Coca-ColaTM and Red BullTM were significantly lower in that case than for the debonded structures. Statistical results evaluating roughness showed that Red BullTM has a more erosive effect than Coca-Cola™. This result is supported by the large contact surface that resulted after debonding. In conclusion, the prolonged exposure of the brackets to acidic drinks affected the bonding strength due to erosion propagation into both the enamel–adhesive interface and the bonding layer. The best resistance to acid erosion was obtained by RMGIC.
Cobalt-chromium (Co-Cr) alloys are widely utilized in dentistry. The salivary pH is a significant factor, which affects the characteristics and the behavior of dental alloys through corrosion. This study aimed to evaluate the corrosion behavior in artificial saliva with different pH values (3, 5.7, and 7.6) of two commercial Co-Cr dental alloys manufactured by casting and by milling. Corrosion resistance was determined by the polarization resistance technique, and the tests were carried out at 37 ± 1 °C, in Carter Brugirard artificial saliva. After the electrochemical parameters, it can be stated that the cast Co-Cr alloy has the lowest corrosion current density, the highest polarization resistance, and the lowest speed of corrosion in artificial saliva with pH = 7.6. In the case of milled Co-Cr alloy, the same behavior was observed, but in artificial saliva with pH = 5.7, it recorded the most electropositive values of open circuit potential and corrosion potential. Although both cast and milled Co-Cr alloys presented a poorer corrosion resistance in artificial saliva with a more acidic pH value, the milled Co-Cr alloy had better corrosion behavior, making this alloy a better option for the prosthetic treatment of patients suffering from GERD.
(1) Background: This study investigated the influence of Bis-GMA, TEGDMA, UDMA, and two different polyethylene glycol (PEG)-containing, UDMO-based co-monomers on the Young’s modulus and flexural strength, degree of methacrylate C=C double bond conversion and residual monomer elution of experimental dental resins. (2) Methods: Urethane methacrylate-based monomer was synthesised via a radical chain growth polymerization mechanism using PEG in order to improve the mechanical properties. Dental resins were formulated using Bis-GMA, UDMA, or UDMO as base monomers combined with TEGDMA as a dilution monomer and DMAEM + CQ as the photo-initiator system. Degree of conversion (DC), mechanical properties, and residual monomer content of light-activated methacrylate resin formulations were evaluated and statistically analysed by ANOVA and a Tukey’s test. (3) Results: PEG-containing UDMO resins had lower Young’s modulus and elastic strength than UDMA-derived resin for all irradiation times. The highest DC (67,418%) was observed for the PEG-containing UDMO-based resin formulation when light cured for 40 s. For all samples, DC increased with the photo-polymerization time. The amount of residual monomer decreased after increasing the light-curing period from 20 to 40 s, resin with UDMO content 0.01 mol of PEG having the smallest amount of free eluted monomer. (4) Conclusions: A strong structure–property relationship exists in photo-cured dimethacrylate-based dental resins. The time and quantity of the photochemical initiation system can influence the physical–mechanical properties of the resins but also the monomers in their composition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.