IMPORTANCETelemedicine is accelerating the remote detection and monitoring of medical conditions, such as vision-threatening diseases. Meaningful deployment of smartphone apps for home vision monitoring should consider the barriers to patient uptake and engagement and address issues around digital exclusion in vulnerable patient populations.OBJECTIVE To quantify the associations between patient characteristics and clinical measures with vision monitoring app uptake and engagement. DESIGN, SETTING, AND PARTICIPANTSIn this cohort and survey study, consecutive adult patients attending Moorfields Eye Hospital receiving intravitreal injections for retinal disease between May 2020 and February 2021 were included.EXPOSURES Patients were offered the Home Vision Monitor (HVM) smartphone app to self-test their vision. A patient survey was conducted to capture their experience. App data, demographic characteristics, survey results, and clinical data from the electronic health record were analyzed via regression and machine learning.MAIN OUTCOMES AND MEASURES Associations of patient uptake, compliance, and use rate measured in odds ratios (ORs). RESULTSOf 417 included patients, 236 (56.6%) were female, and the mean (SD) age was 72.8 (12.8) years. A total of 258 patients (61.9%) were active users. Uptake was negatively associated with age (OR, 0.98; 95% CI, 0.97-0.998; P = .02) and positively associated with both visual acuity in the better-seeing eye (OR, 1.02; 95% CI, 1.00-1.03; P = .01) and baseline number of intravitreal injections (OR, 1.01; 95% CI, 1.00-1.02; P = .02). Of 258 active patients, 166 (64.3%) fulfilled the definition of compliance. Compliance was associated with patients diagnosed with neovascular age-related macular degeneration (OR, 1.94; 95% CI, 1.07-3.53; P = .002), White British ethnicity (OR, 1.69; 95% CI, 0.96-3.01; P = .02), and visual acuity in the better-seeing eye at baseline (OR, 1.02; 95% CI, 1.01-1.04; P = .04). Use rate was higher with increasing levels of comfort with use of modern technologies (β = 0.031; 95% CI, 0.007-0.055; P = .02). A total of 119 patients (98.4%) found the app either easy or very easy to use, while 96 (82.1%) experienced increased reassurance from using the app.CONCLUSIONS AND RELEVANCE This evaluation of home vision monitoring for patients with common vision-threatening disease within a clinical practice setting revealed demographic, clinical, and patient-related factors associated with patient uptake and engagement. These insights inform targeted interventions to address risks of digital exclusion with smartphone-based medical devices.
Background Geographic atrophy is a major vision-threatening manifestation of age-related macular degeneration, one of the leading causes of blindness globally. Geographic atrophy has no proven treatment or method for easy detection. Rapid, reliable, and objective detection and quantification of geographic atrophy from optical coherence tomography (OCT) retinal scans is necessary for disease monitoring, prognostic research, and to serve as clinical endpoints for therapy development. To this end, we aimed to develop and validate a fully automated method to detect and quantify geographic atrophy from OCT. Methods We did a deep-learning model development and external validation study on OCT retinal scans at Moorfields Eye Hospital Reading Centre and Clinical AI Hub (London, UK). A modified U-Net architecture was used to develop four distinct deep-learning models for segmentation of geographic atrophy and its constituent retinal features from OCT scans acquired with HeidelbergSpectralis. A manually segmented clinical dataset for model development comprised 5049 B-scans from 984 OCT volumes selected randomly from 399 eyes of 200 patients with geographic atrophy secondary to age-related macular degeneration, enrolled in a prospective, multicentre, phase 2 clinical trial for the treatment of geographic atrophy (FILLY study). Performance was externally validated on an independently recruited dataset from patients receiving routine care at Moorfields Eye Hospital (London, UK). The primary outcome was segmentation and classification agreement between deep-learning model geographic atrophy prediction and consensus of two independent expert graders on the external validation dataset. Findings The external validation cohort included 884 B-scans from 192 OCT volumes taken from 192 eyes of 110 patients as part of real-life clinical care at Moorfields Eye Hospital between Jan 1, 2016, and Dec, 31, 2019 (mean age 78•3 years [SD 11•1], 58 [53%] women). The resultant geographic atrophy deep-learning model produced predictions similar to consensus human specialist grading on the external validation dataset (median Dice similarity coefficient [DSC] 0•96 [IQR 0•10]; intraclass correlation coefficient [ICC] 0•93) and outperformed agreement between human graders (DSC 0•80 [0•28]; ICC 0•79). Similarly, the three independent feature-specific deep-learning models could accurately segment each of the three constituent features of geographic atrophy: retinal pigment epithelium loss (median DSC 0•95 [IQR 0•15]), overlying photoreceptor degeneration (0•96 [0•12]), and hypertransmission (0•97 [0•07]) in the external validation dataset versus consensus grading. Interpretation We present a fully developed and validated deep-learning composite model for segmentation of geographic atrophy and its subtypes that achieves performance at a similar level to manual specialist assessment. Fully automated analysis of retinal OCT from routine clinical practice could provide a promising horizon for diagnosis and prognosis in both research and real-life patien...
Purpose Biallelic pathogenic variants in ABCA4 are the commonest cause of monogenic retinal disease. The full-field electroretinogram (ERG) quantifies severity of retinal dysfunction. We explored application of machine learning in ERG interpretation and in genotype–phenotype correlations. Methods International standard ERGs in 597 cases of ABCA4 retinopathy were classified into three functional phenotypes by human experts: macular dysfunction alone (group 1), or with additional generalized cone dysfunction (group 2), or both cone and rod dysfunction (group 3). Algorithms were developed for automatic selection and measurement of ERG components and for classification of ERG phenotype. Elastic-net regression was used to quantify severity of specific ABCA4 variants based on effect on retinal function. Results Of the cohort, 57.6%, 7.4%, and 35.0% fell into groups 1, 2, and 3 respectively. Compared with human experts, automated classification showed overall accuracy of 91.8% (SE, 0.169), and 96.7%, 39.3%, and 93.8% for groups 1, 2, and 3. When groups 2 and 3 were combined, the average holdout group accuracy was 93.6% (SE, 0.142). A regression model yielded phenotypic severity scores for the 47 commonest ABCA4 variants. Conclusions This study quantifies prevalence of phenotypic groups based on retinal function in a uniquely large single-center cohort of patients with electrophysiologically characterized ABCA4 retinopathy and shows applicability of machine learning. Novel regression-based analyses of ABCA4 variant severity could identify individuals predisposed to severe disease. Translational Relevance Machine learning can yield meaningful classifications of ERG data, and data-driven scoring of genetic variants can identify patients likely to benefit most from future therapies.
Abstract. Bioluminescence imaging is a noninvasive technique whereby surface weighted images of luminescent probes within animals are used to characterize cell count and function. Traditionally, data are collected over the entire emission spectrum of the source using no filters and are used to evaluate cell count/function over the entire spectrum. Alternatively, multispectral data over several wavelengths can be incorporated to perform tomographic reconstruction of source location and intensity. However, bandpass filters used for multispectral data acquisition have a specific bandwidth, which is ignored in the reconstruction. In this work, ignoring the bandwidth is shown to introduce a dependence of the recovered source intensity on the bandwidth of the filters. A method of accounting for the bandwidth of filters used during multispectral data acquisition is presented and its efficacy in increasing the quantitative accuracy of bioluminescence tomography is demonstrated through simulation and experiment. It is demonstrated that while using filters with a large bandwidth can dramatically decrease the data acquisition time, if not accounted for, errors of up to 200% in quantitative accuracy are introduced in twodimensional planar imaging, even after normalization. For tomographic imaging, the use of this method to account for filter bandwidth dramatically improves the quantitative accuracy. © The Authors. Published by SPIE under a Creative CommonsAttribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requiresfull attribution of the original publication, including its DOI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.