Purpose
Swept Source Optical coherence tomography angiography (SS-OCTA) is a novel technique to visualize perfusion and vascular changes like ischemia in patients with diabetic retinopathy. The aim of this study was to compare non-perfusion areas on conventional fluorescein angiography (FA) with those on SS-OCTA using detailed manual annotation in patients with diabetic macular edema (DME) and to evaluate possible artifacts caused by DME on SS-OCTA.
Methods
27 eyes of 21 patients with DME were analyzed in this prospective, cross-sectional study; on all, standard ophthalmological examination, SS-OCTA and FA imaging were performed. Early-phase FA and SS-OCTA images were analyzed for capillary dropout and foveal avascular zone (FAZ) was measured on both modalities. Artifacts in SS-OCTA imaging caused by DME were marked and analyzed.
Results
The mean age of the patients was 62.6 ± 11.5 years. On FA the mean size of the annotated non-perfusion areas was 0.14 ± 0.31 mm2 whereas the mean size in SS-OCTA was 0.04 ± 0.13 mm2; areas marked on FA were statistically significantly larger than on SS-OCTA (p<0.01). Mean size of FAZs was similar between FA and OCTA images. (p = 0.91). Seven eyes (25.9 percent) showed imaging artifacts due to DME in SS-OCTA.
Conclusion
SS-OCTA is a valid tool to analyze capillary perfusion status of patients with DME, although areas of non-perfusion were measured smaller than in conventional FA. More non-perfusion areas were found on SS-OCTA images. FAZ measurements were similar using the two modalities. However, SS-OCTA is prone to artifacts and therefore requires reviewing of imaging results: up to 25 percent of the analyzed eyes showed artifacts on OCTA, which occurred in the areas of diabetic macular edema and did not correspond to capillary drop out.
Purpose: To evaluate rotational stability, tilt and decentration of a new monofocal IOL with a 7.0 mm optic and frame haptics. Methods: Prospective post-market clinical follow-up study at the Kepler University Hospital Linz, Austria. An Aspira-aXA (HumanOptics, Germany) was implanted in 74 eyes of 42 cataract patients. The lens was manufactured with toric markings. IOL rotational stability was evaluated by comparing its position at the end of surgery (EoS) versus 1 day, 1 week, 1 month and 4 months postoperatively. IOL tilt and decentration were measured using a Scheimpflug camera at 1 week, 1 month and 4 months. Results: Median absolute IOL rotation was 1.42 degrees (n = 52; mean = 2.18 ± 2.23°) within 1 day after surgery and was significantly higher compared to all later intervals (median <1.0 degree; P = .001). At the 4 months follow-up, IOL rotation was within 5.0 degrees in 85% of the eyes (n = 40) and within 10.0 degrees in 98% (n = 46) of the eyes. The only eye with an IOL rotation of ≥ 10.ty0 degrees (EoS vs. 1 day) had an AL of 26.45 mm. At the last follow-up, the IOL vertical and horizontal tilt referenced to the pupillary axis was in average less than 1.5 degrees in both eyes (n = 54; maximum 5.85°). Decentration in both meridians was on average less than 0.10 mm in both eyes (maximum 0.30 mm).
Conclusion:The one-piece Aspira-aXA IOL showed good and stable positioning within the capsular bag over a 4 months period.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.