BackgroundTranscatheter aortic valve implantation (TAVI) is a minimally invasive procedure used to treat degenerative heart valve disease. The implantation requires a highly specific and interdisciplinary management approach. Currently, TAVI is performed with the patient under local or general anaesthesia.MethodsThis study was a retrospective analysis of all TAVI procedures performed at the University Hospital of Regensburg between January 2009 and July 2015. All pre-, intra and postoperative data focusing on perioperative complications were recorded.ResultsA total of 853 transfemoral- and transapical-TAVI patients were included in the study. All patients underwent general anaesthesia. The ASA classifications were primarily 3–4. The average logistic EuroScores for the transfemoral- and transapical-TAVI patients were 18 ± 12% and 21 ± 15% (p = 0.002), respectively. The anaesthesia coverage time was 170 ± 49 min., including 37 ± 12 minutes for anaesthetic management. Overall, 458 complications were recorded; with pneumonia, acute renal failure, indication for a permanent pacemaker and non-extubation in the operating theatre the most frequently recorded complications.ConclusionIn the present study, we showed that our patients’ outcomes are comparable to those reported in the available literature. Compared to TF, TA patients show an overall worse physical condition as well as a higher perioperative morbidity and mortality. Consequently TA patients need additional care and should only be operated in appropriately experienced medical centres.
ObjectivesThis study was performed to analyse anaesthesia-related complications and side effects in patients undergoing transcatheter aortic valve implantation (TAVI) under general anaesthesia.DesignRetrospective study.SettingThe study was performed as a single-centre study in a hospital of tertiary care in Germany.ParticipantsAll 853 patients, who underwent TAVI at the Universitätsklinikum Regensburg between January 2009 and July 2015, were included. 52.5% were female patients.Primary and secondary outcome measuresWe gathered information, such as recent illness, vital parameters and medication administered during the intervention and postoperatively for 12 hours. We analysed all anaesthesia-related complications and anaesthesia-related side effects that occurred during the intervention and entire hospital stay.ResultsWe analysed all 853 TAVI procedures. The mean patient age was 79 ± 6 years. In 99.5% of cases, we used volatile-based anaesthesia. 2.8% (n=24; transfemoral (TF): n=19 [3.8%]; transapical (TA): n=5 [1.4%]) of all cases suffered from anaesthesia-related complications. 819 (TF: n=447; TA: n=372) anaesthesia-related side effects occurred in 586 (68.7%, TF: n=325 [64.2%], TA: n=261 [75.2%]) patients. Neither the complications nor the side effects had any serious consequences. Intraoperative hypothermia in 44% of cases (TF: n=202 [39.9%]; TA: n=173 [49.9%]) and postoperative nausea and vomiting in 27% (n=232; TF: n=131 [25.9%], TA: n=101 [29.1%]) of cases were the most common anaesthesia-related side effects.ConclusionIn this study, serious anaesthesia-related complications were rarely seen, and non-critical anaesthesia-related side effects could have been avoided through consistent prophylaxis and management. Therefore, despite their high anaesthetic risk, general anaesthesia is justifiable in patients who underwent TAVI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.