Background/AimsIntraductal ultrasonography (IDUS) has been performed as an adjunct to endoscopic retrograde cholangiography (ERC) during radiocontrast cholangiography (RC). Radiation exposure during RC poses a health risk to both patients and examiners. We evaluated the feasibility of IDUS without RC in various extrahepatic biliary diseases.MethodsIDUS was performed with the insertion of an IDUS probe from the papilla of Vater to the confluent portion of the common hepatic duct without fluoroscopy. The technical success rate and procedure-related complications were evaluated retrospectively.ResultsWire-guided IDUS without RC was performed in 105 patients. The mean age was 66.5 years, and 50 (47.6%) were male. The IDUS diagnoses included choledocholithiasis (73, 69.5%), benign biliary stricture (11, 10.5%), choledocholithiasis with biliary pancreatitis (9, 8.6%), bile duct cancer (5, 4.8%), pancreatic cancer (1, 0.9%), and others (6, 5.7%). After IDUS, 66 (62.8%) underwent stone removal, 19 (18.1%) underwent biliary drainage, and 7 (6.6%) underwent brush cytology and biopsy. No significant complications such as perforation or severe pancreatitis occurred.ConclusionsIDUS without RC was a feasible and safe approach in patients with various extrahepatic biliary diseases. We anticipate a potentially important role of IDUS in various ERC procedures because it lacks the hazards of RC.
Background/Aims:Endoscopic retrograde biliary drainage (ERBD) has become a standard procedure in patients with a biliary obstruction. Intraductal ultrasonography (IDUS) has emerged as a new tool for managing extrahepatic biliary diseases. IDUS-directed ERBD can be performed without conventional cholangiography (CC). The goal of this study was to assess the effectiveness and safety of IDUS-directed ERBD compared to CC-directed ERBD in patients with an extrahepatic biliary obstruction.Methods:A total of 210 patients who had undergone IDUS-directed ERBD (IDUS-ERBD, n = 105) and CC-directed ERBD (CC-ERBD, n = 105) between October 2013 and April 2014 were analyzed retrospectively. The primary outcome measure was the procedural success rate. Secondary outcome measures included clinical outcomes, total procedure time, radiation exposure time, and overall complication rates.Results:The total technical success rate of ERBD was 100% (105/105) in the IDUS-ERBD and CC-ERBD groups. Mean procedure time was slightly prolonged in the IDUS-ERBD group than that in the CC-ERBD group (32.1 ± 9.9 minutes vs. 28.4 ± 11.6 minutes, p = 0.023). Mean radiation exposure time was one-third less in the IDUS-ERBD group than that in the CC-ERBD group (28.0 ± 49.3 seconds vs. 94.2 ± 57.3 seconds, p < 0.001). No significant differences in complication rates were detected between the groups.Conclusions:IDUS-ERBD was equally effective and safe as CC-ERBD in patients with an extrahepatic biliary obstruction. Although IDUS-ERBD increased total procedure time, it significantly decreased radiation exposure.
Intraductal ultrasonography (IDUS) is one of the most useful diagnostic tools for various extrahepatic biliary diseases. However, conventional IDUS has some limitations in providing accurate cross-sectional imaging of the bile duct in patients with extensive pneumobilia. Using a balloon-sheathed catheter, the US system (balloon-sheathed IDUS) can overcome these limitations. Sixteen patients underwent balloon-sheathed IDUS during endoscopic retrograde cholangiography. The balloon-sheathed IDUS was inserted via a transpapillary route when visualization of the bile duct with conventional IDUS was distorted by extensive pneumobilia. The patient group had a mean age of 65.5 years, and 56.3% (9/16) were male. The balloon-sheathed IDUS permitted successful visualization of the bile duct in all patients, regardless of the extent of pneumobilia. Using this system, remnant common bile duct stones were detected in five patients (31.3%), and cholangiocarcinoma was detected in one patient (6.3%). The balloon-sheath IDUS aided in stone sweeping. No significant complications, including bleeding, perforation, or pancreatitis, occurred in any of the patients. The balloon-sheathed catheter US system was useful and safe for biliary IDUS in patients with extensive pneumobilia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.