BackgroundTransforming growth factor-β1 (TGF-β1) has a critical role in breast cancer initiation and progression.ObjectivesWe have investigated the possible differences in two promoter polymorphisms (-509C/T and -800G/A) of TGF-β1 gene between breast cancer cases and controls.Patients and MethodsA total of 100 patients with confirmed breast cancer and 100 subjects without breast cancer was selected. Two promoter polymorphisms (-509C/T and -800G/A) of TGF-β1 gene were genotyped using PCR-based restriction fragment length polymorphism (RFLP) method.ResultsThe allele frequencies were 63% for C allele and 37% for T allele of SNP -509C/T and 66% for G allele and 34% for A allele of SNP -800G/A. Although no significant difference has observed between two groups, according to the genotype distribution, However, the TT genotype of -509 and AA genotype of -800 was significantly associated with breast cancer risk [odds ratio (OR) = 2.409; 95% confidence interval (CI) = 1.087 - 5.337, P = 0.030; and OR = 2.383; CI = 1.039 - 5.40, P = 0.040, respectively]. In addition, a multinomial logistic regression model shown, homozygous of -800 G/A (OR = 0.570; 95% CI = 0.362 - 0.896, P = 0.015); and HDL-C (OR = 0.935; 95% CI = 0.906 - 0.965, P < 0.001) were the selected variables associated with the presence of breast cancer. Haplotype analysis has shown no significant association between TGF-β1 haplotypes and breast cancer risk.ConclusionsOur results indicated that among two promoter polymorphisms of the TGF-β1gene, -800G/A compared to -509C/T is more associated with breast cancer.
The purpose of this in vitro study is to evaluate the effectiveness of incorporating a new irrigation system into a surgical guide and monitor its effect on heat generation during implant bed preparation. A total of 48 surgically guided osteotomies were performed on 12 bovine ribs divided into 4 groups, using different irrigation techniques: Group A (test) had entry and exit channels incorporated into the guide; Group B had a similar design with an entry channel only; Group C had conventional external irrigation; and Group D (control) had no irrigation. Heat generation during the osteotomies was measured using thermocouples placed at a depth of 2 mm and 6 mm. The lowest mean temperature was observed in Group A (22.1 °C at 2 mm and 21.4 °C at 6 mm), which was statistically significant when compared with Groups C and D (p < 0.001). Group A showed a lower mean temperature compared with Group B as well; however, it was statistically significant only at 6 mm depth (p < 0.05). In conclusion, the proposed surgical guide has significantly reduced heat generation during implant osteotomy compared to conventional external irrigation. The integration of an exit cooling channel can resolve limitations found in previously designed surgical guides such as debris blockage and can be easily incorporated into computer designing and 3D printing software.
The purpose of this in vitro study is to evaluate the effectiveness of incorporating a new irrigation system into a surgical guide and monitor its effect on heat generation during implant bed preparation. A total of 48 surgically guided osteotomies were performed on 12 bovine ribs divided into 4 groups, using different irrigation techniques: Group A (test) had entry and exit channels incorporated into the guide; Group B had a similar design with an entry channel only; Group C had conventional external irrigation; Group D (control) had no irrigation. Heat generation during the osteotomies was measured using thermocouples placed at a depth of 2 mm and 6 mm. The lowest mean temperature was observed in Group A (22.1°C at 2mm and 21.4°C at 6mm), this was statistically significant when compared with Groups C and D (p&lt;0.001). Group A showed a lower mean temperature compared with Group B as well, however statistically significant only at 6mm depth (p&lt;0.05). In conclusion, the proposed guide has significantly reduced heat generation during implant osteotomy. The integration of an exit cooling channel can resolve limitations found in previously designed surgical guides and can be easily incorporated into computer designing and 3D printing software.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.