Objective Treatment decisions in inflammatory bowel diseases are increasingly based on longitudinal tracking of calprotectin results. Many hospital laboratories measure calprotectin levels in sent-in stool samples with an enzyme-linked immunosorbent assay (ELISA). Several manufacturers introduced a lateral flow–based test with software application that turns a smartphone camera into a reader for quantitative measurements. We compared three home tests (IB Doc , QuantonCal and CalproSmart) and companion ELISA tests (fCAL, IDK-Calprotectin and Calprotectin-ALP) to see if measurement pairs agreed sufficiently. Design A method comparison study was conducted with stool samples from patients with active or quiescent inflammatory bowel disease. Medical students without any specific laboratory training carried out the home tests with two iOS (iPhone 6 and 7) and two Android devices (Samsung Galaxy S6 and Motorola Moto G5 Plus). Two experienced laboratory technicians measured the calprotectin concentration with the ELISA method. Primary outcome was test agreement (defined as percentage of paired measurements within predefined limits of difference). Secondary outcome included reading error rate (RER) per smartphone type. Results We performed 1440 smartphone readings and 120 ELISA tests. In the low calprotectin range (≤500 μg/g) IB Doc , QuantOnCal and CalproSmart showed 87%, 82% and 76% agreement with their companion ELISAs. In the high range (>500 μg/g) the agreement was 37%, 19% and 37%, respectively. CalproSmart and QuantOnCal had significantly higher RERs than IB Doc (respectively 5.8% and 4.8%, versus 1.9%). Forty-three percent of reading errors was on the Motorola device, in particular with the QuantOnCal application. Conclusions All three calprotectin home tests and companion ELISAs agreed sufficiently when concentrations are ≤500 μg/g. To minimize wrongful interpretation of calprotectin changes over time it is essential to always use the home test and companion ELISA of one and the same manufacturer. Manufacturers should explicitly evaluate and report the suitability of commonly used smartphones for quantitative calprotectin readings.
The findings of this cohort study suggest that MTX is an effective immunomodulator to maintain remission after stopping thiopurines. MTX maintenance should be considered before stepping up to anti-tumor necrosis factor alpha therapy. MTX is probably somewhat more effective in patients who stopped thiopurines due to side effects than in those who failed on thiopurines.
BackgroundTreatment decisions in children with inflammatory bowel disease (IBD) are increasingly based on longitudinal tracking of faecal calprotectin concentrations, but there is little known about the stability of this protein in stool.MethodsWe stored aliquots of homogenised stool at room temperature and at 4°C, and measured the calprotectin concentration for 6 consecutive days with three different assays. In addition, we assessed calprotectin stability in assay-specific extraction buffers kept at room temperature.ResultsAfter 6 days of storage at room temperature, mean percentage change from baseline calprotectin concentrations in stool and extraction buffer was 35% and 46%, respectively. The stability of calprotectin was significantly better preserved in samples stored at 4°C (p=0.0066 and 0.0011, respectively).ConclusionsCalprotectin is not stable at room temperature. Children with IBD and their caretakers may be falsely reassured by low calprotectin values. The best advisable standard for preanalytical calprotectin handling is refrigeration of the stool sample until delivery at the hospital laboratory.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.