Among patients with stage T1b, T1c, T2a, or T2b prostate adenocarcinoma and a PSA level of 20 ng per milliliter or less, the use of short-term ADT for 4 months before and during radiotherapy was associated with significantly decreased disease-specific mortality and increased overall survival. According to post hoc risk analysis, the benefit was mainly seen in intermediate-risk, but not low-risk, men. (Funded by the National Cancer Institute; RTOG 94-08 ClinicalTrials.gov number, NCT00002597.).
Background
Androgen deprivation therapy (ADT) is associated with coronary heart disease and diabetes in men with prostate cancer (PCa); however, controversy exists regarding ADT and cardiovascular mortality (CVM) with limited data for lower risk disease.
Objective
We conducted a hypothesis-generating retrospective analysis to evaluate the relationship between short-course ADT and CVM in patients with clinically localized PCa enrolled in a phase 3 trial.
Design, setting, and participants
A total of 1979 men with clinically localized (T1b–2b, prostate-specific antigen [PSA] <20 ng/ml) PCa enrolled in Radiation Therapy Oncology Group (RTOG) 94-08 from 1994 to 2001. Patients were randomized to radiation therapy (RT) with or without short-course ADT (4 mo of gonadotropin-releasing hormone (GnRH) agonist therapy and antiandrogen). Median follow-up was 9.1 yr for survivors.
Outcome measurements and statistical analysis
The Cox proportional hazards model assessed overall survival. The Fine-Gray proportional hazards model assessed disease-specific survival (DSS) and CVM. Covariates included age, race, weight, baseline cardiovascular disease, baseline diabetes, baseline hypertension, Gleason score, T stage, and PSA.
Results and limitations
Short-course ADT improved overall survival and DSS and was not associated with an increased risk of CVM. Overall, 191 cardiovascular-related deaths were observed. At 10 yr, 83 patients (cumulative incidence rate: 10%) receiving RT and ADT versus 95 patients (cumulative incidence rate: 11%) receiving RT alone experienced CVM. The treatment arm was not associated with increased CVM (unadjusted hazard ratio: 1.07; confidence interval, 0.81–1.42; p = 0.62). Increased CVM was not observed in patients at low risk of PCa death or at high risk of cardiac-related death.
Conclusions
Data from patients enrolled in RTOG 94-08 support the hypothesis that ADT does not increase CVM risk in all men with clinically localized PCa treated with short-course GnRH agonist therapy. These data support ADT use in settings with proven survival benefit.
Patient summary
We investigated the controversial relationship between hormone therapy and cardiovascular mortality in men with prostate cancer (PCa) treated with radiation in a large randomized trial. Our data suggest that hormone therapy does not increase the risk of cardiovascular death in patients with clinically localized PCa and support the use of such therapy in settings with proven survival benefit.
During an ultrasound (US) scan, the sonographer is in close contact with the patient, which puts them at risk of COVID-19 transmission. In this paper, we propose a robot-assisted system that automatically scans tissue, increasing sonographer/patient distance and decreasing contact duration between them. This method is developed as a quick response to the COVID-19 pandemic. It considers the preferences of the sonographers in terms of how US scanning is done and can be trained quickly for different applications. Our proposed system automatically scans the tissue using a dexterous robot arm that holds US probe. The system assesses the quality of the acquired US images in real-time. This US image feedback will be used to automatically adjust the US probe contact force based on the quality of the image frame. The quality assessment algorithm is based on three US image features: correlation, compression and noise characteristics. These US image features are input to the SVM classifier, and the robot arm will adjust the US scanning force based on the SVM output. The proposed system enables the sonographer to maintain a distance from the patient because the sonographer does not have to be holding the probe and pressing against the patient's body for any prolonged time. The SVM was trained using bovine and porcine biological tissue, the system was then tested experimentally on plastisol phantom tissue. The result of the experiments shows us that our proposed quality assessment algorithm successfully maintains US image quality and is fast enough for use in a robotic control loop.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.