Background
While most pancreatic fluid collections (PFCs) resolve spontaneously, endoscopic ultrasound-guided transluminal drainage (EUS-TD) may be necessary. EUS-TD has evolved from multiple double-pigtail plastic stents (DPPS) to fully covered self-expanding metal stents (FCSEMS) and lumen-apposing metal stents (LAMS). This study compares clinical attributes of DPPS, FCSEMS and LAMS.
Methods
This is a single-centre retrospective review of EUS-TD for PFCs. The primary outcome was clinical success. Secondary outcomes were technical success, procedure time, hospital length of stay (HLOS), number of endoscopies, need for necrosectomy, adverse events (AEs) and overall cost.
Results
Fifty-eight patients (37 male, average age 49 years) underwent a total of 60 EUS-TD procedures for PFCs (average size 11.2 cm with 29 pseudocysts and 29 walled-off necrosis). Ten patients (17%) underwent EUS-TD with DPPS and 48 patients (83%) with metal stents (32 FCSEMS, 16 LAMS). Overall technical and clinical success was 100% and 84%, respectively. Lumen-apposing metal stents had shorter procedure times (14.9 versus 63.6 DPPS, 39.1 min FCSEMS, P < 0.001), and no difference in AEs (3 of 16 versus 4 of 10 DPPS, 12 of 34 FCSEMS, ns). Double-pigtail plastic stents required more endoscopies (3.7 versus 2.3 LAMS, 2.3 FCSEMS, P = 0.013) and necrosectomies (4 of 10 [40%]) compared with 5 of 34 [15%] in the FCSEMS group and 3 of 16 [19%] in the LAMS group, respectively, P = 0.001) to achieve clinical resolution. The overall cost and HLOS was not significantly different between groups.
Conclusion
The use of LAMS for PFCs is not associated with any significant increase in cost despite technical (shorter procedure time) and clinical advantages (shorter indwell time, reduced need for necrosectomy and no increase in AEs).
Background
Endoscopic ultrasound-guided transmural drainage is the preferred management of pancreatic fluid collections (PFCs). Optimizing drainage is important and there remains debate as to the choice of stent. A recent trend towards the use of lumen-apposing metal stents (LAMS) has emerged.
Aim
To evaluate the performance characteristics of a LAMS based on a prospective protocol (CT scan 1 week after placement to assess for resolution and need for necrosectomy followed by stent removal within 3 weeks).
Methods
This is a descriptive prospective cohort study performed at a single centre. The primary outcome was clinical success. Secondary outcomes were technical success, procedure time, total number of endoscopic procedures with or without necrosectomy, stent indwell time, stent functionality and adverse events.
Results
Thirty-seven patients (21 males, mean age 46.5 years) underwent placement of LAMS for 41 PFCs (median size 12 cm). There were 18 pseudocysts and 23 walled-off necrosis. Clinical success was seen in 33 of 41 (80%) PFCs. Of the remaining eight patients, six underwent surgery and two patients died from underlying malignant disease (although their PFC had completely resolved). Technical success and stent functionality were 100%. The median procedure time was 14 min (interquartile range 11 min to 20 min). Of the 23 walled-off necrosis, 9 (39%) required necrosectomy. The median stent indwell time was 19 days (interquartile range 14 to 22 days). There were no serious adverse events.
Conclusions
Our protocol demonstrates excellent performance characteristics of LAMS. Their clinical efficacy and favourable safety profile suggest that they may be the preferred modality for endoscopic ultrasound-guided management of PFCs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.