BackgroundIn elderly individuals an increased muscle strength contributes to the diminution of the falls risk and associated adverse events. An increasing interest in lateral control exists due to the fatal consequences of postero-lateral falls. Therefore a proper assessment of frontal plane hip muscle strength in elderly is important but remains challenging.Therefore we aimed to investigate the feasibility and repeatability of a hip abductor and adductor maximum voluntary isometric strength (MVIS) and rate of force generation (RFG) test in elderly. This represents an initial step in the development process of a new and clinically relevant test that could lead to more specific treatment protocols for this population.MethodsIn this measurement focused study hip abduction (ABD) and adduction (ADD) MVIS and RFG were tested twice within one to three hours with a dynamometer fixed to a custom made frame in a geriatric population including fallers and non-fallers. Intraclass correlation coefficient (ICCagreement), standard error of measurement (SEM), and smallest detectable difference (SDD) were determined.ResultsAll recruited persons (N = 76; mean age (SD) 80.46 (7.05) years old) completed the tests. The average time needed to complete the strength tests was 10.58 min. (1.56) per muscle group. The reliability of the hip ABD and ADD was high with ICC’sagreement ranging from 0.83 to 0.97. The SDD varied between 18.1 and 81.8% depending on the muscle group and type of strength that was evaluated.ConclusionHip abductor and adductor strength measures in older person are feasible and reliable. However, the significance of moderate changes in these measurements may be limited by the large SDD and SEM. Therefore, physical therapist should be careful when using this measure for assessing the progress of an individual person in a daily clinical use.
BackgroundHip muscle weakness in older people seems to be an influencing factor of falls. Currently, it is unclear which muscles out of the hip muscle group play an important role in older people. A validating process in the measurement regarding muscle strength related to falls is necessary before answering that question.ObjectiveFirstly, we aimed to investigate which hip muscle group strength shows an acceptable level of distinction between older adult fallers and non-fallers compared to a predefined external criterion regarding falling. Secondly, we aimed to compare the same outcomes and questions for hand-grip strength in relation to the same external criterion.DesignThis study was a cross-sectional validity study.MethodsThe maximum voluntary isometric strength (MVIS) and the rate of force generation of hip abductors (ABD), adductors, internal and external rotators, extensors, and flexors were measured with a dynamometer fixed to a custom-made frame as well as hand-grip strength with a Martin Vigorimeter in 60 older people aged over 65 years (38 females and 22 males).ResultsThe area under the curve (AUC) and the results of the mean decrease in Gini index assessed by random forest approach show that of all the assessed parameters, hip ABD MVIS showed the highest discriminative value regarding the chosen external criterion in older people (AUC ABD MVIS 0.825, 95% confidence interval: 0.712–0.938).ConclusionResults indicate that ABD MVIS is a useful measure to distinguish between older adult fallers and non-fallers regarding the chosen external criterion.
Diminished hip abductor strength decreases postural control which is a parameter that is associated with an increased risk of ankle sprains. In our study we evaluated the influence of hip abductor fatigue on sagittal plane ankle kinematics and shank muscle activity during a single-leg forward jump. Sagittal ankle plane kinematics are important in ankle sprains but less studied than frontal plane kinematics. Therefore, we evaluated differences in sagittal ankle kinematics (12-camera motion capture system) and lower limb surface electromyographic muscle activity in 20 healthy, recreationally active adults (9 females, 11 males, mean age 30.3 SD 4.0 years, mean BMI 23.6 SD 2.8 kg/m) before and after a hip abductor fatigue protocol (200-ms prior, at and in the 250-ms following initial contact (IC)). After fatigue, the maximal ankle plantar-flexion angle decreased prior to IC (median 3.8° [interquartile range 0.1, 7.2], p = 0.014), at IC (4.1° [-0.3, 5.0], p = 0.027) and post IC (4.1° [-1.3, 5.0] p = 0.036). Gastrocnemius activity onset was delayed (-28.0 ms [-44.0, 0.0], p < 0.01). Average activity of the tibialis anterior increased prior to IC (pre-fatigue 19.32% [14.89, 33.45], post-fatigue 28.95% [18.49, 34.81], p < 0.05). Hip-abductor fatigue influenced sagittal ankle kinematics and shank muscle activity during single-leg landings.
Background/Objectives Early detection of fall risk is crucial for targeted fall prevention and rehabilitation. This systematic review facilitates decision-making concerning the optimal choice for a suitable fall risk assessment test for older persons in four different settings. This systematic review provides an overview of reliability and diagnostic accuracy (sensitivity [SE], specificity, likelihood ratios, and post-test probabilities) of commonly used performance measures to assess older persons’ fall risk. Methods Two reviewers independently screened titles, abstracts, and full texts of all articles identified through a systematic search on the PubMed, Embase, CINAHL, and Web of Science databases. The methodological quality was critically appraised using the Quality Assessment of Diagnostic Accuracy Studies-2 tool and the COSMIN risk of bias tool. Due to a setting-dependent fall risk, four relevant settings were selected for the analyses: 1) community dwelling, 2) nursing home, 3) hospital, and 4) the combined setting of hospitalized and community-dwelling persons. Results Recommendations for diagnostic accuracy can be made for the specific settings: setting 1) mini-balance evaluation system test, timed up and go test with fast speed (TUG FAST), cognitive TUG FAST, functional reach test, and fast gait speed; 2) TUG at usual speed; 3) none of the included tests; and 4) some hip muscle strength and hand grip strength tests might be recommended. Conclusion The review’s results are applicable for use in clinical practice, both on a population and on an individual level for patients and caregivers. Most measures’ reliability is sufficient. However, the included tests’ discriminative ability is not optimal for clinical use in relevant settings. The low sample sizes of most of the included studies and a limited amount of studies in all but the community-dwelling setting hinder us from making strong recommendations.
Background/Objectives: Early detection of fall risk in persons older than 65 is of clinical relevance, but the diagnostic accuracy of currently used functional tests (eg short physical performance battery [SPPB] and timed up and go test [TUG]) to assess older persons' fall risks remains moderate. Recent literature highlights the importance of strong hip abductors to prevent falls. We thus aimed to assess the diagnostic accuracy of hip abductor strength measures to assess older persons' fall risks. Methods: Hip abductor maximum voluntary isometric strength (ABD MVIS), rate of force generation (ABD RFG), and the SPPB and TUG functional fall risk assessments were assessed in 60 persons aged over 65 years (82.0 ± 6.1 years). The diagnostic accuracy (area under the curve [AUC], sensitivity [sens], specificity [spec], positive predictive value [PPV], negative predictive value [NPV], and positive and negative likelihood ratios [LR + , LR − ]) was evaluated at a clinically important 90% sensitivity level. Cutoff values for clinical use were calculated. Results: In our population, hip ABD MVIS (AUC 0.8, sens 90.6%, spec 57.1%, PPV 70.7%, NPV 84.2%, LR+ 2.1, LR-0.2, and cutoff value ≤ 1.1 N/kg) and hip ABD RFG (AUC 0.8, sens 90.6%, spec 46.4%, PPV 65.9%, NPV 81.3%, LR+ 1.7, LR-0.2, and cutoff ≤ 8.47 N/kg/s) show diagnostic accuracy comparable to other fall risk assessments (SPPB and TUG) and a high net sensitivity when used in a test battery. Conclusion: Hip ABD MVIS or RFG shows good diagnostic accuracy to differentiate between older fallers and nonfallers compared to the chosen external criterion history of falls. The high net sensitivity when hip ABD MVIS or RFG is combined with currently used fall risk assessments shows promise in contributing value to a test battery and should be investigated further in longitudinal studies.
IntroductionBariatric surgery leads to loss of fat and fat-free mass (FFM). To preserve FFM it is recommended that weight loss interventions are accompanied by physical activity. However, it remains unknown if functional capacities spontaneously improve after a substantial weight loss. Study’s aim was to assess the effect of bariatric surgery on strength, functional capacities and quality of life of participants with a body mass index (BMI) ≥ 35 kg/m2.MethodAnthropometric parameters (weight, BMI, waist circumference), physical functions (quadriceps strength, walking capacity, spatio-temporal gait parameters, dynamic balance, lower limb power) and quality of life were assessed before and at three months after the bariatric surgery in 33 individuals who did not follow any physical activity program.ResultsThe anthropometric parameters, quality of life and three functional abilities (walking capacity, normal gait speed and lower limb power) improved significantly three months post-surgery. In contrast, fast gait speed, absolute strength, normalized strength, and dynamic balance did not improve.DiscussionA massive weight loss should be accompanied by an exercise program aiming to maintain FFM and to enhance muscle strength and balance. Such a program might also enhance functional capacities and help to sustain the weight loss over time.
BackgroundReduced hip muscle strength has been shown to be a major factor related to falls in older persons. However, comprehensive assessment of hip abduction strength in the clinical setting is challenging. The aim of this study was to investigate the feasibility and intra-rater reliability of a quick and simple hip abductor strength test in a functional standing position.MethodsIndividuals over 65 years of age were recruited from the geriatric department of a university hospital and an outpatient clinic. Thirty-two older subjects, including 16 fallers (≥1 fall during the last 12 months) and 16 non-fallers were included. Maximum voluntary isometric strength (MVIS) and rate of force generation (RFG) of the hip abductors of the right leg were evaluated in a standing position using a hand-held dynamometer. Two test-sessions were carried out. All hip strength values were normalized to participants’ weight. Reliability was determined using the intra-class correlation coefficient agreement (ICCagreement), the standard error of measurement (SEM) and a Bland and Altman analysis (BA).ResultsAll participants completed the strength tests, which took a mean 2.47 ± 0.49 min (one limb). Intra-rater reliability was higher for MVIS (0.98[0.95–0.99]) than RFG (ICC = 0.93[0.87–0.97]) for the entire sample. In the non-fallers, ICC was 0.98[0.95–1.00] (SEM = 0.08 N.kg− 1) for MVIS and 0.88[0.75–0.96] for RFG (SEM = 1.34 N.kg-1.s-1). In the fallers, ICC was 0.94[0.89–0.98] (SEM = 0.11 N.kg− 1) for MVIS and 0.93[0.84–0.98] (SEM = 1.12 N.kg− 1.s− 1) for RFG. The BA plot showed that the MVIS and RFG values did not differ across test-sessions, showing that no learning effect occurred (no systematic effect). The mean differences between test-sessions were larger and the LOA smaller in the fallers than in the non-fallers.ConclusionAssessment of hip strength in a standing position is feasible, rapid and reliable. We therefore recommend this position for clinical practice. Future studies should investigate the diagnostic value of hip abductor strength in standing to discriminate between fallers and non-fallers, and to determine if change in strength following a falls prevention program reduces the risk of falls.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.