One of the benefits of Digital PCR (dPCR) is the potential for unparalleled precision enabling smaller fold change measurements. An example of an assessment that could benefit from such improved precision is the measurement of tumour-associated copy number variation (CNV) in the cell free DNA (cfDNA) fraction of patient blood plasma. To investigate the potential precision of dPCR and compare it with the established technique of quantitative PCR (qPCR), we used breast cancer cell lines to investigate HER2 gene amplification and modelled a range of different CNVs. We showed that, with equal experimental replication, dPCR could measure a smaller CNV than qPCR. As dPCR precision is directly dependent upon both the number of replicate measurements and the template concentration, we also developed a method to assist the design of dPCR experiments for measuring CNV. Using an existing model (based on Poisson and binomial distributions) to derive an expression for the variance inherent in dPCR, we produced a power calculation to define the experimental size required to reliably detect a given fold change at a given template concentration. This work will facilitate any future translation of dPCR to key diagnostic applications, such as cancer diagnostics and analysis of cfDNA.
BACKGROUND Digital PCR (dPCR) is an increasingly popular manifestation of PCR that offers a number of unique advantages when applied to preclinical research, particularly when used to detect rare mutations and in the precise quantification of nucleic acids. As is common with many new research methods, the application of dPCR to potential clinical scenarios is also being increasingly described. CONTENT This review addresses some of the factors that need to be considered in the application of dPCR. Compared to real-time quantitative PCR (qPCR), dPCR clearly has the potential to offer more sensitive and considerably more reproducible clinical methods that could lend themselves to diagnostic, prognostic, and predictive tests. But for this to be realized the technology will need to be further developed to reduce cost and simplify application. Concomitantly the preclinical research will need be reported with a comprehensive understanding of the associated errors. dPCR benefits from a far more predictable variance than qPCR but is as susceptible to upstream errors associated with factors like sampling and extraction. dPCR can also suffer systematic bias, particularly leading to underestimation, and internal positive controls are likely to be as important for dPCR as they are for qPCR, especially when reporting the absence of a sequence. SUMMARY In this review we highlight some of the considerations that may be needed when applying dPCR and discuss sources of error. The factors discussed here aim to assist in the translation of dPCR to diagnostic, predictive, or prognostic applications.
The emerging technique of microfluidic digital PCR (dPCR) offers a unique approach to real-time quantitative PCR for measuring nucleic acids that may be particularly suited for low-level detection. In this study, we evaluated the quantitative capabilities of dPCR when measuring small amounts (<200 copies) of DNA and investigated parameters influencing technical performance. We used various DNA templates, matrixes, and assays to evaluate the precision, sensitivity and reproducibility of dPCR, and demonstrate that this technique can be highly reproducible when performed at different times and when different primer sets are targeting the same molecule. dPCR exhibited good analytical sensitivity and was reproducible outside the range recommended by the instrument manufacturer; detecting 16 estimated targets with high precision. The inclusion of carrier had no effect on this estimated quantity, but did improve measurement precision. We report disagreement when using dPCR to measure different template types and when comparing the estimated quantities by dPCR and UV spectrophotometry. Finally, we also demonstrate that preamplification can impose a significant measurement bias. These findings provide an independent assessment of low copy molecular measurement using dPCR and underline important factors for consideration in dPCR experimental design.
Circulating cell-free DNA (cfDNA) is becoming an important clinical analyte for prenatal testing, cancer diagnosis and cancer monitoring. The extraction stage is critical in ensuring clinical sensitivity of analytical methods measuring minority nucleic acid fractions, such as foetal-derived sequences in predominantly maternal cfDNA. Consequently, quality controls are required for measurement of extraction efficiency, fragment size bias and yield for validation of cfDNA methods. We evaluated the utility of an external DNA spike for monitoring these parameters in a study comparing three specific cfDNA extraction methods [QIAamp® circulating nucleic acid (CNA) kit, NucleoSpin® Plasma XS (NS) kit and FitAmp™ plasma/serum DNA isolation (FA) kit] with the commonly used QIAamp DNA blood mini (DBM) kit. We found that the extraction efficiencies of the kits ranked in the order CNA kit > DBM kit > NS kit > FA kit, and the CNA and NS kits gave a better representation of smaller DNA fragments in the extract than the DBM kit. We investigated means of improved reporting of cfDNA yield by comparing quantitative PCR measurements of seven different reference gene assays in plasma samples and validating these with digital PCR. We noted that the cfDNA quantities based on measurement of some target genes (e.g. TERT) were, on average, more than twofold higher than those of other assays (e.g. ERV3). We conclude that analysis and averaging of multiple reference genes using a GeNorm approach gives a more reliable estimate of total cfDNA quantity.FigureComparison of single and multiple reference gene normalisation for quantification of plasma cell free DNAElectronic supplementary materialThe online version of this article (doi:10.1007/s00216-014-7835-3) contains supplementary material, which is available to authorized users.
Digital PCR (dPCR) is a highly accurate molecular approach, capable of precise measurements, offering a number of unique opportunities. However, in its current format dPCR can be limited by the amount of sample that can be analysed and consequently additional considerations such as performing multiplex reactions or pre-amplification can be considered. This study investigated the impact of duplexing and pre-amplification on dPCR analysis by using three different assays targeting a model template (a portion of the Arabidopsis thaliana alcohol dehydrogenase gene). We also investigated the impact of different template types (linearised plasmid clone and more complex genomic DNA) on measurement precision using dPCR. We were able to demonstrate that duplex dPCR can provide a more precise measurement than uniplex dPCR, while applying pre-amplification or varying template type can significantly decrease the precision of dPCR. Furthermore, we also demonstrate that the pre-amplification step can introduce measurement bias that is not consistent between experiments for a sample or assay and so could not be compensated for during the analysis of this data set. We also describe a model for estimating the prevalence of molecular dropout and identify this as a source of dPCR imprecision. Our data have demonstrated that the precision afforded by dPCR at low sample concentration can exceed that of the same template post pre-amplification thereby negating the need for this additional step. Our findings also highlight the technical differences between different templates types containing the same sequence that must be considered if plasmid DNA is to be used to assess or control for more complex templates like genomic DNA.
MicroRNAs (miRNAs) are short (~22 nucleotides), non-coding RNA molecules that post-transcriptionally regulate gene expression. As the miRNA field is still in its relative infancy, there is currently a lack of consensus regarding optimal methodologies for miRNA quantification, data analysis and data standardization. To investigate miRNA measurement we selected a panel of both synthetic miRNA spikes and endogenous miRNAs to evaluate assay performance, copy number estimation, and relative quantification. We compared two different miRNA quantification methodologies and also assessed the impact of short RNA enrichment on the miRNA measurement. We found that both short RNA enrichment and quantification strategy used had a significant impact on miRNA measurement. Our findings illustrate that miRNA quantification can be influenced by the choice of methodology and this must be considered when interpreting miRNA analyses. Furthermore, we show that synthetic miRNA spikes can be used as effective experimental controls for the short RNA enrichment procedure.
BACKGROUND Tyrosine kinase inhibitors (TKIs) are the cornerstone of successful clinical management of patients with chronic myeloid leukemia (CML). Quantitative monitoring of the percentage of the fusion transcript BCR-ABL1 (breakpoint cluster region–c-abl oncogene 1, non-receptor tyrosine kinase) BCR-ABL1IS (%BCR-ABL1IS) by reverse transcription–quantitative PCR (RT-qPCR) is the gold standard strategy for evaluating patient response to TKIs and classification into prognostic subgroups. However, this approach can be challenging to perform in a reproducible manner. Reverse-transcription digital PCR (RT-dPCR) is an adaptation of this method that could provide the robust and standardized workflow needed for truly standardized patient stratification. METHODS BCR-ABL1 and ABL1 transcript copy numbers were quantified in a total of 102 samples; 70 CML patients undergoing TKI therapy and 32 non-CML individuals. 3 commercially available digital PCR platforms (QS3D, QX200 and Raindrop) were compared with the platform routinely used in the clinic for RT-qPCR using the EAC (Europe Against Cancer) assay. RESULTS Measurements on all instruments correlated well when the %BCR-ABL1IS was ≥0.1%. In patients with residual disease below this level, greater variations were measured both within and between instruments limiting comparable performance to a 4 log dynamic range. CONCLUSIONS RT-dPCR was able to quantify low-level BCR-ABL1 transcript copies but was unable to improve sensitivity below the level of detection achieved by RT-qPCR. However, RT-dPCR was able to perform these sensitive measurements without use of a calibration curve. Adaptions to the protocol to increase the amount of RNA measured are likely to be necessary to improve the analytical sensitivity of BCR-ABL testing on a dPCR platform.
Background SARS-CoV-2 RNA quantities, measured by reverse transcription quantitative PCR (RT-qPCR), have been proposed to stratify clinical risk or determine analytical performance targets. We investigated reproducibility and how setting diagnostic cut-offs altered the clinical sensitivity of COVID-19 testing. Methods Quantitative SARS-CoV-2 RNA distributions (Cq and copies/mL) from more than 6000 patients from three clinical laboratories in UK, Belgium and the Republic of Korea were analyzed. Impact of Cq cut-offs on clinical sensitivity was assessed. The June/July 2020 INSTAND EQA scheme SARS-CoV-2 materials were used to estimate laboratory reported copies/mL and to estimate the variation in copies/mL for a given Cq. Results When the WHO suggested Cq cut-off of 25 was applied, the clinical sensitivity dropped to as little as about 16%. Clinical sensitivity also dropped to as little as about 27% when a simulated LOD of 106 copies/mL was applied. The inter-laboratory variation for a given Cq value was >1000 fold in copies/mL (99% CI). Conclusion While RT-qPCR has been instrumental in the response to COVID-19, we recommend Cq (Ct or Cp) values not be used to set clinical cut-offs, or diagnostic performance targets, due to poor inter-laboratory reproducibility; calibrated copy-based units (used elsewhere in virology) offer more reproducible alternatives. We also report a phenomenon where diagnostic performance may change relative to the effective reproduction number (R). Our findings indicate that the disparities between patient populations across time are an important consideration when evaluating or deploying diagnostic tests. This is especially relevant to the emergency situation of an evolving pandemic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.