Background
The hand hygiene (HH) behaviour of the general public and its effect on illnesses are issues of growing importance. Gender is associated with HH behaviour. HH efficiency is a combination of washing efficiency and hand drying, but information about the knowledge level and HH behaviour of the general public is relatively limited. The findings of this cross-sectional study can substantially contribute to the understanding on the knowledge gap and public behaviour towards HH, thereby providing information on gender-specific health promotion activities and campaigns to improve HH compliance.
Methods
An epidemiological investigation by using a cross-sectional study design on the general public was conducted either via an online platform (SurveyMonkey) or paper-and-pen methods. The hand-washing and -drying questionnaire was used for data collection.
Results
A total of 815 valid questionnaires were collected. Majority of the respondents can differentiate the diseases that can or cannot be transmitted with poor HH, but the HH knowledge of the respondents was relatively inadequate. The female respondents had a significantly better HH knowledge than male respondents. The multiple regression analysis results also indicated that females had a significantly higher knowledge score by 0.288 towards HH than males after adjusting for age and education level. Although the majority of the respondents indicated that they performed hand cleaning under different specific situations, they admitted only using water instead of washing their hands with soap. More males than females dried their hands on their own clothing, whereas more females dried their hands through air evaporation. The average time of using warm hand dryers was generally inadequate amongst the respondents.
Conclusions
Being a female, middle-aged and having tertiary education level are protective factors to improve HH knowledge. Misconceptions related to the concepts associated with HH were noted amongst the public. Self-reported practice on hand drying methods indicated that additional education was needed. The findings of this study can provide information on gender-specific health promotion activities and creative campaigns to achieve sustained improvement in HH practices.
The CSPS demonstrated satisfactory results on the basis of the standard international criteria on psychometric testing, which ascertained the reliability and validity of this instrument in measuring the compliance of clinical nurses with standard precautions. The cross-cultural pilot testing further reinforced the instrument's relevance and applicability in most developed and developing regions.
N95 respirators are recommended by the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) to prevent the inhalation of droplets which may transmit respiratory pathogens. The reliability of N95 respirators in preventing transmission depends on their fit to the wearer. Quantitative fit testing (QNFT) is the gold standard used to determine this fit objectively. The manufacturers of the respirators also recommend performing a self-reported user-seal-check to detect for leakage. This study aims to investigate the capability of the user-seal-check in determining the fit of N95 respirators by investigating the sensitivity and specificity of the user-seal-check compared with QNFT. A prospective and cross-sectional research design was used. A total of 204 local Chinese undergraduate nursing students were recruited to test two commonly used respirator models (3M 1860S and 3M 1862). The results of the user-seal-check were compared with the results of the gold standard QNFT using the Condensation Nucleus Counter Fit Tester System. The sensitivity and specificity of the user-seal-check results obtained with the respirators were calculated. The results indicated low sensitivity, accuracy and predictive value of the user-seal-check in determining the fit of the N95 respirators. The user-seal-check was not found to be reliable as a substitute for QNFT. The results also suggested that the user-seal-check may be unreliable for detecting gross leakage. We recommend that QNFT is used to determine the fit of N95 respirators.
Psychological health among healthcare workers (HCWs) has become a major concern since the COVID-19 outbreak. HCWs perceived risks of contracting COVID-19, in relation to depression were investigated. It was hypothesized that perceived high risk of contracting COVID-19 (close contact with cases, inadequate provision of personal protective equipment, insufficient infection control training, and presence of symptoms) would be significant predictors of depression. Our cross-sectional survey was completed by HCWs across three regions (Hubei, Guangdong, Hong Kong) between March 9 to April 9 2020 using convenience sampling. Depression was assessed using the 9-item Patient Health Questionnaire (PHQ-9). Prevalence of depression was 50.4% (95%
Objective
The COVID-19 pandemic is a large-scale public health emergency that likely precipitated sleep disturbances in the community. This study aimed to investigate the prevalence and correlates of sleep disturbances during the early phase of COVID-19 pandemic.
Methods
This web-based cross-sectional study recruited 1138 Hong Kong adults using convenience sampling over a two-week period from 6th April 2020. The survey collected data on sleep disturbances, mood, stress, stock of infection control supplies, perceived risk of being infected by COVID-19, and sources for acquiring COVID-19 information. The participants were asked to compare their recent sleep and sleep before the outbreak. The Insomnia Severity Index (ISI) was used to assess their current insomnia severity. Prevalence was weighted according to 2016 population census.
Results
The weighted prevalence of worsened sleep quality, difficulty in sleep initiation, and shortened sleep duration since the outbreak were 38.3%, 29.8%, and 29.1%, respectively. The prevalence of current insomnia (ISI score of ≥10) was 29.9%. Insufficient stock of masks was significantly associated with worsened sleep quality, impaired sleep initiation, shortened sleep duration, and current insomnia in multivariate logistic regression (adjusted OR = 1.57, 1.72, 1.99, and 1.96 respectively, all
p
< 0.05).
Conclusion
A high proportion of people in Hong Kong felt that their sleep had worsened since the COVID-19 outbreak. Insufficient stock of masks was one of the risk factors that were associated with sleep disturbances. Adequate and stable supply of masks may play an important role to maintain the sleep health in the Hong Kong general population during a pandemic outbreak.
Keywords:Mask fit Usability Nanofibre technology N95 filtering facepiece respirators Nursing Physical properties
S U M M A R YBackground: The reliability of N95 filtering facepiece respirators (FFRs) depends on correct fitting. The perceived usability of FFRs is equally important because discomfort during usage may affect compliance. Body movements during nursing procedures may also increase the risk of face seal leakage. Aim: To evaluate the mask fit and usability of the best-fitting 3M N95 FFR and the nanofibre N95 FFR before and after nursing procedures. The physical properties of these FFRs were also examined. Methods: This experimental study had a one-group multiple comparison design. In total, 104 nursing students participated, and performed nursing procedures for 10 min when wearing the best-fitting 3M FFR and the nanofibre FFR. Mask fit and perceived usability of the FFRs were evaluated. Findings: More participants failed to obtain a fit factor !100 when using the best-fitting 3M FFR than when wearing the nanofibre FFR (33.7% vs 21.2%) after the procedures (P¼0.417). The nanofibre FFR also demonstrated higher usability than the 3M FFRs in terms of facial heat, breathability, facial pressure, speech intelligibility, itchiness, difficulty of maintaining the mask in place, and comfort level (P<0.001). The nanofibre FFR was also lighter, thinner and had slightly higher bacterial filtration efficiency than the 3M FFRs. Conclusion: The nanofibre FFR demonstrated significantly better usability than the 3M FFRs. None of the respirators were able to provide consistent protection for the wearer, as detected by face seal leakage after performing nursing procedures. Further improvement in the prototype design is needed to increase compliance and ensure the respiratory protection of users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.