AimTo determine the prevalence of apical periodontitis and assess the quality of endodontic fillings in the population of the city of Zagreb, Croatia.MethodsA total of 1462 orthopantomograms from new patients at 6 different dental practices was analyzed during 2006 and 2007. The presence of periapical lesions was determined by using the periapical index score (PAI). The quality of endodontic fillings was assessed according to the filling length and homogeinicity. Data were analyzed using t test and ANOVA with Scheffe post-hoc test.ResultsThere were 75.9% of participants with endodontically treated teeth and 8.5% of all teeth were endodontically treated. Only 34.2% of endodontically treated roots had adequate root canal filling length, while 36.2% of root canal fillings had homogenous appearance. From the total number of teeth with intracanal post, 17.5% had no visible root canal filling. Using PAI 3 as a threshold value for apical periodontitis, periapical lesions were detected in 8.5% of teeth. Adequate quality of root canal fillings was associated with a lower prevalence of periapical lesions.ConclusionWe found a large proportion of endodontically treated teeth with apical periodontitis and a correlation between the quality of endodontic filling and the prevalence of periapical lesions. This all suggests that it is necessary to improve the quality of endodontic treatment in order to reduce the incidence and prevalence of apical periodontitis.
The examined subjects prescribe antibiotics according to the curriculum taught at the School of Dental Medicine for majority of types, doses and duration of the treatments, although antibiotics over-prescription in cases without medical indication was observed. The national guidelines on antibiotic regimens are required in order to reduce unnecessary antibiotic use.
The purpose of the study was to determine the wear rate of Equia Forte HT Fil with Equia Forte Coat or without coating and compare it with Fuji IX GP high-viscosity glass ionomer cement (GIC) in conditions with acid load or at neutral pH. The samples were stored for 7 days: (1) in artificial saliva, (2) in artificial saliva and cyclically exposed to low pH, and (3) in distilled water and cyclically exposed to low pH. Wear was determined by measuring the difference in mass before and after brushing in an abrasion testing device. The wear of Fuji IX GP was significantly higher than that of Equia Forte HT Fil with or without coating (p = 0.000). The difference between Equia Forte HT Fil with and without Coat was not statistically significant (p < 0.803). The differences in wear resistance between samples stored in saliva and in distilled water were not significant (p = 0.588). Periodic exposure to the low pH solution significantly affected the wear resistance of all materials (p = 0.000). Equia Forte HT Fil was more resistant to wear than Fuji IX GP in all storage conditions. A resinous coat did not significantly increase wear resistance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.