The rapid increase in the number of CT acquisitions during the COVID-19 pandemic raised concerns about increased radiation exposure to patients and the resultant radiation-induced health risks. It prompted researchers to explore newer CT techniques like ultra-low dose CT (ULDCT), which could improve patient safety. Our aim was to study the utility of ultra-low dose CT (ULDCT) chest in the evaluation of acute COVID-19 pneumonia with standard-dose CT (SDCT) chest as a reference standard. This was a prospective study approved by the institutional review board. 60 RT-PCR positive COVID-19 patients with valid indication for CT chest underwent SDCT and ULDCT. ULDCT and SDCT were compared in terms of objective (noise and signal-to-noise ratio) and subjective (noise, sharpness, artifacts and diagnostic confidence) image quality, various imaging patterns of COVID-19, CT severity score and effective radiation dose. The sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy of ULDCT for detecting lung lesions were calculated by taking SDCT as a reference standard. The mean age of subjects was 47.2 ± 10.7 years, with 66.67% being men. 90% of ULDCT scans showed no/minimal noise and sharp images, while 93.33% had image quality of high diagnostic confidence. The major imaging findings detected by SDCT were GGOs (90%), consolidation (76.67%), septal thickening (60%), linear opacities (33.33%), crazy-paving pattern (33.33%), nodules (30%), pleural thickening (30%), lymphadenopathy (30%) and pleural effusion (23.33%). Sensitivity, specificity and diagnostic accuracy of ULDCT for detecting most of the imaging patterns were 100% (p < 0.001); except for GGOs (sensitivity: 92.59%, specificity: 100%, diagnostic accuracy: 93.33%), consolidation (sensitivity: 100%, specificity: 71.43%, diagnostic accuracy: 93.33%) and linear opacity (sensitivity: 90.00%, specificity: 100%, diagnostic accuracy: 96.67%). CT severity score (range: 15–25) showed 100% concordance on SDCT and ULDCT, while effective radiation dose was 4.93 ± 1.11 mSv and 0.26 ± 0.024 mSv, respectively. A dose reduction of 94.38 ± 1.7% was achieved with ULDCT. Compared to SDCT, ULDCT chest yielded images of reasonable and comparable diagnostic quality with the advantage of significantly reduced radiation dose; thus, it can be a good alternative to SDCT in the evaluation of COVID-19 pneumonia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.