Subjects who had undergone either trabeculectomy or tube shunt surgery showed a similar IOP response to the WDT. Subjects on systemic antihypertensive medications experienced significantly greater IOP fluctuations during the test.
Background: This study aimed to investigate whether performing a laser peripheral iridotomy in primary angle-closure suspects had an effect on the intraocular pressure response during the water-drinking test.Design: Prospective study in a hospital setting.Participants: Primary angle-closure suspects scheduled for a laser peripheral iridotomy.Methods: Primary angle-closure suspects were evaluated before the laser peripheral iridotomy and 2 weeks after. On each visit, subjects underwent the waterdrinking test. Intraocular pressure was measured every 15 min within a 1-h period.Main Outcome Measures: Intraocular pressure fluctuations during the water drinking test.Results: Twenty patients were enrolled. The mean age was 58.1 years (±10.2 SD), predominantly female (n = 14, 70%). Average intraocular pressure range (maximum-minimum) during the waterdrinking test increased significantly from 2.6 ± 1.1 mmHg before the laser peripheral iridotomy to 3.5 ± 1.5 mmHg after (P = 0.04). The mean difference between peak and last intraocular pressure measurements increased after the laser peripheral iridotomy was performed, from 2.5 mmHg (±1.27 SD) to 3.3 mmHg (±1.66 SD), (P = 0.057). There was no change in mean peak intraocular pressure (maximum-baseline) before and after the laser peripheral iridotomy (P = 0.87).Conclusions: Primary angle-closure suspects who underwent the water-drinking test had a slightly more pronounced recovery of intraocular pressure after the laser peripheral iridotomy was performed, which may be attributed to increase in the area of exposed trabecular meshwork following treatment. Differences in intraocular pressure curves before and after laser peripheral iridotomy were minimal, and therefore, the water-drinking test had limited value as a provocative test in this patient population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.