This study aims to compare the outputs of the waist-worn Active style Pro HJA-350IT (ASP; used in studies with Asian populations), the waist-worn ActiGragh™GT3X+ using the normal filter (GT3X+) and the thigh-worn activPAL3 (AP) in assessing adults’ sedentary behaviour (total sedentary time, number of breaks) under free-living conditions. Fifty healthy workers wore the three monitors simultaneously during their waking hours on two days, including a work day and a non-work day. Valid data were at least 10 hours of wearing time, and the differences between monitors on the sedentary outputs using the AP as criterion measurement were analyzed by ANOVA. The number of participants who had complete valid data for work day and non-work day was 47 and 44, respectively. Total sedentary time and breaks estimated by the AP were respectively 466.5 ± 146.8 min and 64.3 ± 24.9 times on the work day and 497.7 ± 138.3 min and 44.6 ± 15.4 times on the non-work day. In total sedentary time, the ASP estimated 29.7 min (95%CI = 7.9 to 51.5) significantly shorter than the AP on the work day but showed no significant difference against the AP on the non-work day. The GT3X+ estimated 80.1 min (54.6 to 105.6) and 52.3 (26.4 to 78.2) significantly longer than the AP on the work day and the non-work day, respectively. For the number of breaks from sedentary time, on both days, the ASP and the GT3X+ estimated significantly more than the AP: 14.1 to 15.8 times (6.3 to 22.5) for the ASP and 27.7 to 28.8 times (21.8 to 34.8) for the GT3X+. Compared to the AP as the criterion, the ASP can underestimate total sedentary time and the GT3X+ can overestimate it, and more so at the lower levels of sedentary time. For breaks from sedentary time, compared to the AP, both the GT3X+ the ASP can overestimate.
BackgroundGood quality measures of Japanese adults’ sedentary behaviors are needed to accurately assess correlates of specific sedentary behaviors. The present study assessed criterion validity of total sedentary behavior and test-retest reliability of six domain-specific sedentary behaviors.MethodsWe administered a questionnaire, based on previous studies, that measured domain-specific sedentary behaviors. To examine validity, agreement between self-reported time spent in sedentary behaviors from the questionnaire and objectively-measured sedentary time using accelerometers was compared among 392 adults (aged 40–64 years) in two Japanese cities. For reliability, a 2-week interval test-retest was administered to a convenience sample of 34 participants.ResultsThe correlation between total self-reported and objectively measured sedentary time was significant (all P < 0.001) and fair-to-good for workdays (ρ = 0.57) and whole week (ρ = 0.49), but was low for non-workdays (ρ = 0.23). The difference between the two measures was significant for whole week (z = −2.25, P = 0.03) and non-workdays (z = −5.50, P < 0.001), but was not significant for workdays (z = −0.60, P = 0.55). There was a significant positive association between the difference in the two measures and the average of these two measures (workdays: r = 0.53; non-workdays: r = 0.45; and whole week: r = 0.54, all P < 0.001). There was fair-to-good test-retest reliability of total sedentary time for each domain (workdays: interclass correlation coefficient [ICC] = 0.77, non-workdays: ICC = 0.53, and whole week: ICC = 0.7; all P < 0.01).ConclusionsThe scale of domain-specific sedentary behaviors is reliable for estimating where and for what purpose Japanese adults spend their sedentary time, and total sedentary time is valid for workdays and the whole week.
Different models of accelerometer have the potential to provide a different estimate of the same physical activity or sedentary behavior. Our study compared the outputs of the Active Style Pro (ASP) and ActiGraph (AG) devices in assessing predicted metabolic equivalents (METs) for specific activities under laboratory conditions. Thirty healthy young adults wore two hip accelerometers (ASP and AG), simultaneously while performing twenty-two activities (eight sedentary, eight household, and six ambulatory activities) in a controlled laboratory setting. For the AG, predicted METs for each activity was calculated using four equations based on vertical-axis and vector magnitude data. Separate paired t-tests and Bland–Altman analysis examined the difference and agreement in METs between AG using four commonly used equations and ASP measurements for each activity. AG devices using different equations calculated significantly different outcomes for most activities compared with ASP devices. The smallest differences in predicted METs estimates between ASP and AG were observed for ambulatory activities. Ambulatory activities demonstrated the best agreement between ASP and AG regardless of which AG equation was used. Our findings can be used to assist researchers in their selection of accelerometer and output estimation equations for measuring physical activity and sedentary behavior in adults.
Various accelerometers have been used in research measuring physical activity (PA) and sedentary behavior (SB). This study compared two triaxial accelerometers—Active style Pro (ASP) and ActiGraph (AG)—in measuring PA and SB during work and nonwork days in free-living conditions. A total of 50 working participants simultaneously wore these two accelerometers on one work day and one nonwork day. The difference and agreement between the ASP and AG were analyzed using paired t-tests, Bland–Altman plots, and intraclass coefficients, respectively. Correction factors were provided by linear regression analysis. The agreement in intraclass coefficients was high among all PA intensities between ASP and AG. SB in the AG vertical axis was approximately 103 min greater than ASP. Regarding moderate-to-vigorous-intensity PA (MVPA), ASP had the greatest amount, followed by AG. There were significant differences in all variables among these devices across all day classifications, except for SB between ASP and AG vector magnitude. The correction factors decreased the differences of SB and MVPA. PA time differed significantly between ASP and AG. However, SB and MVPA differences between these two devices can be decreased using correction factors, which are useful methods for public health researchers.
Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24–62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland–Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.