Background To assess if radiomics can differentiate benign and malignant subsolid lung nodules (SSNs) on baseline or follow up chest CT examinations. If radiomics can differentiate between benign and malignant subsolid lung nodules, the clinical implications are shorter follow up CT imaging and early recognition of lung adenocarcinoma on imaging. Materials and methods The IRB approved retrospective study included 36 patients (mean age 69 ± 8 years; 5 males, 31 females) with 108 SSNs (31benign, 77 malignant) who underwent follow up chest CT for evaluation of indeterminate SSN. All SSNs were identified on both baseline and follow up chest CT. DICOM CT images were deidentified and exported into the open access 3D Slicer software (version 4.7) to obtain radiomic features. Logistic regression analyses and receiver operating characteristic (ROC) curves for various quantitative parameters were generated with SPSS statistical software. Results Only 2/92 radiomic features (cluster shade and surface volume ratio) enabled differentiation between malignant and benign SSN on baseline chest CT ( P = 0.01 and 0.03) with moderate accuracy [AUC 0.624 (0.505–0.743)]. On follow-up CT, 52/92 radiomic features were significantly different between benign and malignant SSN (P: 0.04 - < 0.0001) with improved accuracy [AUC: 0.708 (0.605–0.811), P = 0.04 - < 0.0001]. Radiomics of benign SSN were stable over time, whereas 63/92 radiomic features of malignant SSNs changed significantly between the baseline and follow up chest CT (P: 0.04 - < 0.0001). Conclusions Temporal changes in radiomic features of subsolid lung nodules favor malignant etiology over benign. The change in radiomics features of subsolid lung nodules can allow shorter follow up CT imaging and early recognition of lung adenocarcinoma on imaging. Radiomic features have limited application in differentiating benign and early malignant SSN on baseline chest CT.
Breast cancer rates are rising in low- and middle-income countries (LMICs), yet there is a lack of accessible and cost-effective treatment. As a result, the cancer burden and death rates are highest in LMICs. In an effort to meet this need, our work presents the design and feasibility of a low-cost cryoablation system using widely-available carbon dioxide as the only consumable. This system uses an 8-gauge outer-diameter needle and Joule-Thomson expansion to percutaneously necrose tissue with cryoablation. Bench top experiments characterized temperature dynamics in ultrasound gel demonstrated that isotherms greater than 2 cm were formed. Further, this system was applied to mammary tumors in an in vivo rat model and necrosis was verified by histopathology. Finally, freezing capacity under a large heat load was assessed with an in vivo porcine study, where volumes of necrosis greater than 1.5 cm in diameter confirmed by histopathology were induced in a highly perfused liver after two 7-minute freeze cycles. These results demonstrate the feasibility of a carbon-dioxide based cryoablation system for improving solid tumor treatment options in resource-constrained environments.
Purpose: To assess the frequency, appropriateness, and radiation doses associated with multiphase computed tomography (CT) protocols for routine chest and abdomen–pelvis examinations in 18 countries. Materials and Methods: In collaboration with the International Atomic Energy Agency, multi-institutional data on clinical indications, number of scan phases, scan parameters, and radiation dose descriptors (CT dose–index volume; dose–length product [DLP]) were collected for routine chest (n = 1706 patients) and abdomen–pelvis (n = 426 patients) CT from 18 institutions in Asia, Africa, and Europe. Two radiologists scored the need for each phase based on clinical indications (1 = not indicated, 2 = probably indicated, 3 = indicated). We surveyed 11 institutions for their practice regarding single-phase and multiphase CT examinations. Data were analyzed with the Student t test. Results: Most institutions use multiphase protocols for routine chest (10/18 institutions) and routine abdomen–pelvis (10/11 institutions that supplied data for abdomen–pelvis) CT examinations. Most institutions (10/11) do not modify scan parameters between different scan phases. Respective total DLP for 1-, 2-, and 3-phase routine chest CT was 272, 518, and 820 mGy·cm, respectively. Corresponding values for 1- to 5-phase routine abdomen–pelvis CT were 400, 726, 1218, 1214, and 1458 mGy cm, respectively. For multiphase CT protocols, there were no differences in scan parameters and radiation doses between different phases for either chest or abdomen–pelvis CT ( P = 0.40-0.99). Multiphase CT examinations were unnecessary in 100% of routine chest CT and in 63% of routine abdomen–pelvis CT examinations. Conclusions: Multiphase scan protocols for the routine chest and abdomen–pelvis CT examinations are unnecessary, and their use increases radiation dose.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.