To identify π ± and K ± in the region of 1.0 ∼ 2.5 GeV/c, a threshold Cherenkov counter equipped with silica aerogels has been investigated. Silica aerogels with a low refractive index of 1.013 have been successfully produced using a new technique. By making use of these aerogels as radiators, we have constructed a Cherenkov counter and have checked its properties in a test beam. The obtained results have demonstrated that our aerogel was transparent enough to make up for loss of the Cherenkov photon yield due to a low refractive index. Various configurations for the photon collection system and some types of photomultipliers, such as the fine-mesh type, for a read out were also tested. From these studies, our design of a Cherenkov counter dedicated to π/K separation up to a few GeV/c with an efficiency greater than 90 % was considered.
Background/Aim: The local control rate of chondrosarcomas treated with carbon-ion radiotherapy (CIRT) worsens as tumour size increases, possibly because of the intra-tumoural linear energy transfer (LET) distribution. This study aimed to evaluate the relationship between local recurrence and intra-tumoural LET distribution in chondrosarcomas treated with CIRT. Patients and Methods: Thirty patients treated with CIRT for grade 2 chondrosarcoma were included. Dose-averaged LET (LET d ) distribution was calculated by the treatment planning system, and the relationship between LET d distribution in the planning tumour volume (PTV) and local control was evaluated. Results: The mean LET d value in PTV was similar between cases with and without recurrence. Recurrence was not observed in cases where the effective minimum LET d value exceeded 40 keV/μm. Conclusion: LET d distribution in PTV is associated with local control in chondrosarcomas and patients treated with ion beams of higher LET d may have an improved local control rate for unresectable chondrosarcomas.
Background and purpose: Several studies have focused on increasing the linear energy transfer (LET) within tumours to achieve higher biological effects in carbon-ion radiotherapy (C-ion RT). However, it remains unclear whether LET affects late complications. We assessed whether physical dose and LET distribution can be specific factors for late rectal complications in C-ion RT. Materials and methods: Overall, 134 patients with uterine carcinomas were registered and retrospectively analysed. Of 134 patients, 132 who were followed up for >6 months were enrolled. The correlations between the relative biological effectiveness (RBE)-weighted dose based on the Kanai model (the ostensible ''clinical dose"), dose-averaged LET (LETd), or physical dose and rectal complications were evaluated. Rectal complications were graded according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Results: Nine patients developed grade 3 or 4 late rectal complications. Linear regression analysis found that D 2cc in clinical dose was the sole risk factor for !grade 3 late rectal complications (p = 0.012). The receiver operating characteristic analysis found that D 2cc of 60.2 Gy (RBE) was a suitable cut-off value for predicting !grade 3 late rectal complications. Among 35 patients whose rectal D 2cc was !60.2 Gy (RBE), no correlations were found between severe rectal toxicities and LETd alone or physical dose per se. Conclusion: We demonstrated that severe rectal toxicities were related to the rectal D 2cc of the clinical dose in C-ion RT. However, no correlations were found between severe rectal toxicities and LETd alone or physical dose per se.
Proton therapy has the physical advantage of a Bragg peak that can provide a better dose distribution than conventional x-ray therapy. However, radiation exposure of normal tissues cannot be ignored because it is likely to increase the risk of secondary cancer. Evaluating secondary neutrons generated by the interaction of the proton beam with the treatment beam-line structure is necessary; thus, performing the optimization of radiation protection in proton therapy is required. In this research, the organ dose and energy spectrum were calculated from secondary neutrons using Monte Carlo simulations. The Monte Carlo code known as the Particle and Heavy Ion Transport code System (PHITS) was used to simulate the transport proton and its interaction with the treatment beam-line structure that modeled the double scattering body of the treatment nozzle at the National Cancer Center Hospital East. The doses of the organs in a hybrid computational phantom simulating a 5-y-old boy were calculated. In general, secondary neutron doses were found to decrease with increasing distance to the treatment field. Secondary neutron energy spectra were characterized by incident neutrons with three energy peaks: 1×10, 1, and 100 MeV. A block collimator and a patient collimator contributed significantly to organ doses. In particular, the secondary neutrons from the patient collimator were 30 times higher than those from the first scatter. These results suggested that proactive protection will be required in the design of the treatment beam-line structures and that organ doses from secondary neutrons may be able to be reduced.
We have fabricated a second-harmonic-generation device with a new walk-off-compensating structure of -BaB 2 O 4 (BBO) by room-temperature bonding. The 5-mm-long device, which consists of four 1-mm-thick plates and additional input and output plates of 0.5 mm thickness, generated nearly twice the UV second-harmonic power compared with a bulk BBO crystal. Moreover, we found that the device can improve the beam shape of the output UV light, which is otherwise degraded in a bulk crystal due to the walk-off effect. #
We propose a two-step method to converse human tissue materials from patient computed tomography (CT) images, which is required in dose reconstructions for a retrospective study of carbon-ion radiotherapy (CIRT) using Monte Carlo (MC) simulation. The first step was to assign the standard tissues of the International Commission on Radiological Protection reference phantoms according to the CT-number. The second step was to determine the mass density of each material based on the relationship between CT-number and stopping power ratio (Hounsfield unit [HU]-SPR) registered in treatment planning system (TPS). Direct implementation of the well-calibrated HU-SPR curve allows the reproduction of previous clinical treatments recorded in TPS without uncertainty due to a mismatch of the CT scanner or scanning conditions, whereas MC simulation with realistic human tissue materials can fulfill the out-of-field dose, which was missing in the record. To validate our proposed method, depth-dose distributions in the homogenous and heterogeneous phantoms irradiated by a 400 MeV/u carbon beam with an 8 cm spread-out Bragg peak (SOBP) were computed by the MC simulation in combination with the proposed methods and compared with those of TPS. Good agreement of the depth-dose distributions between the TPS and MC simulation (within a 1% discrepancy in range) was obtained for different materials. In contrast, fluence distributions of secondary particles revealed the necessity of MC simulation using realistic human tissue. The proposed material assignment method will be used for a retrospective study using previous clinical data of CIRT at the National Institute of Radiological Sciences (NIRS).
In recent years, there has been considerable research into functional materials inspired by living things. Much attention has been paid to the development of adhesive materials that mimic the adhesive proteins secreted by a mussel’s foot. These mussel-inspired materials have superior adhesiveness to various adherents owing to the non-covalent interactions of their polyphenolic moieties, e.g., hydrogen bonding, electrostatic interactions, and even hydrophobic interactions. Various factors significantly affect the adhesiveness of mussel-inspired polymers, such as the molecular weight, cross-linking density, and composition ratio of the components, as well as the chemical structure of the polyphenolic adhesive moieties, such as l-3,4-dihydroxyphenylalanine (l-Dopa). However, the contributions of the position and distribution of the adhesive moiety in mussel-inspired polymers are often underestimated. In the present study, we prepared a series of mussel-inspired alkyl methacrylate copolymers by controlling the position and distribution of the adhesive moiety, which are known as “forced gradient copolymers”. We used a newly designed gallic-acid-bearing methacrylate (GMA) as the polyphenolic adhesive moiety and copolymerized it with 2-ethylhexyl methacrylate (EHMA). The resulting forced gradient adhesive copolymer of GMA and EHMA (poly(GMA-co-EHMA), Poly1) was subjected to adhesion and dispersion tests with an aluminum substrate and a BaTiO3 nanoparticle in organic solvents, respectively. In particular, this study aims to clarify how the monomer position and distribution of the adhesive moiety in the mussel-inspired polymer affect its adhesion and dispersion behavior on a flat metal oxide surface and spherical inorganic oxide surfaces of several tens of nanometers in diameter, respectively. Here, forced gradient copolymer Poly1 consisted of a homopolymer moiety of EHMA (Poly3) and a random copolymer moiety of EHMA and GMA (Poly4). The composition ratio of GMA and the molecular weight were kept constant among the Poly1 series. Simultaneous control of the molecular lengths of Poly3 and Poly4 allowed us to discuss the effects on the distribution of GMA in Poly1. Poly1 exhibited apparent distribution dependency with regard to the adhesiveness and the dispersibility of BaTiO3. Poly1 showed the highest adhesion strength when the composition ratio of GMA was approximately 9 mol% in the portion of the Poly4 segment. In contrast, the block copolymer consisting of the Poly3 segment and Poly4 segment with only adhesive moiety 1 showed the lowest viscosity for dispersion of BaTiO3 nanoparticles. These results indicate that copolymers with mussel-inspired adhesive motifs require the proper design of the monomer position and distribution in Poly1 according to the shape and characteristics of the adherend to maximize their functionality. This research will facilitate the rational design of bio-inspired adhesive materials derived from plants that outperform natural materials, and it will eventually contribute to a sustainable circular economy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.