SUMMARYThe 11 March 2011 M 9.0 Great East Japan earthquake generated significant long-duration shaking that propagated hundreds of kilometers from the epicenter and affected urban areas throughout much of Honshu. Recorded responses of a tall building at 770 km from the epicenter of the mainshock and other related or unrelated events show how structures sensitive to long-period motions can be affected by distant sources. Even when the largest peak input motions to the building is about 3% g, the strong-shaking duration was about 140 s. The 300-to 1000-s prolonged responses of the building are primarily due to a combination of site resonance (e.g. structural fundamental frequency~0.15 Hz and site frequency~0.13-0.17 Hz) and low damping (~1-2%) of the structure. Response modification technologies can improve the response of the building during future earthquakes. The need-to-consider risks to such built environments from distant sources are emphasized.
During the 2011 Tohoku-oki earthquake, a large number of response records from various types of buildings were obtained. The records give us the actual motions of buildings during the exceptionally large earthquakes that are considered comparable with design earthquakes. Various types of earthquake response records have been collected, and their properties with several buildings that will exhibit implications for structural design are discussed.
A sparsely instrumented 55-story building in Osaka, Japan, had recorded unprecedented, severe, and long-duration, long-period resonating responses during the 11 March 2011 M9.0 Tohoku earthquake that occurred at 767 km distance. Thereafter, studies of the records resulted in the implementation of a significant retrofit design, comprising dampers and buckling restrained braces (BRBs). The responses of the retrofitted building were also recorded during the 24 April 2016 M7.3 Kumamoto earthquake that occurred at 478 km. The earthquake and on-demand acquired ambient response data are analyzed in this study to assess the impact of this rare, retrofitted and instrumented tall building subjected to long period strong shaking from events originating at far distances. As expected, the fundamental frequency and critical damping ratio of the building increased, albeit small, after the retrofit as compared to before the retrofit. Increase of damping percentage is a positive finding and indicates that even larger percentages may be attained under shaking stronger than the 2016 event. The records indicate that the building still experiences significant resonance, torsion, as well as a beating effect.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.