Depending on the study of the master curve technique, a temperature correction model for the polarization current of transformer polymer (cellulose) insulation, considering the effects of both moisture content (mc%) and temperature is proposed. In the current work, the shift factors of polarization current curves of samples with various moisture contents are extracted at different temperatures. Then, the variation law among the shift factor, test temperature, and moisture content are studied so as to establish the corresponding functional relationship. The findings reveal that the modified model derived from the above functional relationship could be employed to perform the temperature correction of oil-immersed polymer samples with various insulation states. Therefore, the proposed temperature correction model in this paper will promote the state assessment of the field transformer polymer insulation.
The accuracy and feasibility of the traditional XY model of transformer oil-paper insulation system are disputable since it ignored the effect of non-uniform aging and conductance on dielectric response property. Given this issue, this work attempted to report a modified XY model to overcome these defects. The novelty of this work is in the exploration of the modified XY model as a potential tool for establishing the quantitative correlation among the complex relative permittivity of the liquid insulation, solid insulation, and liquid-solid composite insulation. In that respect, the presented verification experiments proved the feasibility and accuracy of the reported model. The contributions are expected to provide a theoretical basis for the condition evaluation of transformer solid insulation under non-uniform aging conditions.
Frequency domain spectroscopy (FDS) technique is widely applied in the condition assessment of the oil-paper system in power transformers. However, the synergistic effect generated by moisture and temperature on the FDS data cannot be analyzed by the existing model since the single independent variable (moisture or temperature) is considered in the construction of the model. To quantify such the synergistic effect, a novel method that utilized for normalizing (or standardizing) the FDS curve is reported based on the theory of the power series and fitting analysis. The present findings reveal that the reported method is capable of predicting the dielectric loss (tanδ) curve under diverse test conditions, in which the average error is less than 7%. The synergistic effect can be also explored by using the extracted feature parameters. The potential application is then proved to make up for the measurement errors during the FDS test, the findings are expected to promote the moisture analysis of the transformer insulation.
Operating temperature is an important parameter of thyristors to ensure the stable operation of power electronic devices. Thermal management technology is of great significance for improving the reliability of thyristors. In this study, the performance of a phase change material (PCM) mesh-finned heat sink is investigated for the thermal management of thyristors. A multi-physical coupling model of the PCM mesh-finned heat sink is established to analyze the effects of different power losses, air velocities, heights of fins, and thickness of PCM on the thermal performance of the PCM heat sink. The influence of thermal and flow fields on PCM is considered in this model. Furthermore, the heat sink design is optimized to improve the thermal performance based on the calculation results of thermal network parameters. The results show that the power losses, the air velocity, the height of fins, and the thickness of PCM significantly affect the protection ability of the PCM heat sink. After optimizing the heat sink, the PCM heat sink provides 80 s protection time and 100 s recovery time. The PCM mesh-finned heat sink demonstrated good potential for the thermal management of thyristors.
The measurement of polarization and depolarization currents (PDC) based on time–domain response is an effective method for state assessment of cellulose insulation material in oil-immersed electrical equipment. However, the versatility of the data obtained at different temperatures is limited because of the temperature dependence of the PDC. In this respect, the universal conversion of PDC data at different temperatures is an essential aspect to improve the accuracy of the determination of insulating properties of cellulose materials immersed in the oil. Thus, an innovative temperature conversion method based on polarization time-varying current (PTC, obtained by multiplying the polarization current and time) is proposed in this article. In the current work, the PTC data at different temperatures are obtained from the oil-immersed cellulose pressboards with different moisture. Afterwards, the functional model based on the power series theory is used to simulate the PTC data, through which the coefficients of the power series are found related to the test temperature of the PTC and the moisture content (mc%) of the oil-immersed cellulose pressboards. Furthermore, the functional relationship among moisture, test temperatures, and the feature parameter calculated by these coefficients is established. Thus, the PTC data at various temperatures can be calculated by the established function. The potential application ability of the proposed method is verified by comparing the calculated results with the measured results obtained from the various samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.