The results suggest that the clinical benefits observed in this study are the result of non-placebo treatment effects afforded by IDB. IDB should be recommended to select the patients with chronic discogenic low back pain. (Clinicaltrials.gov number, NCT00750191.).
Lidocaine 5% patches did not reduce acute or persistent pain in patients having robotic thoracic surgery, though pain scores were low in both treatment groups. Clinicians should choose alternative analgesic approaches in these patients.
Background Glucose-insulin-potassium (GIK) administration during cardiac surgery inconsistently improves myocardial function, perhaps because hyperglycemia negates the beneficial effects of GIK. The hyperinsulinemic normoglycemic clamp (HNC) technique may better enhance the myocardial benefits of GIK. We extended previous GIK investigations by: 1) targeting normoglycemia while administering a glucose-insulin-potassium infusion (HNC); 2) using improved echocardiographic measures of myocardial deformation, specifically myocardial longitudinal strain and strain rate; and, 3) assessing activation of glucose metabolic pathways. Methods 100 patients having aortic valve replacement for aortic stenosis were randomly assigned to HNC (high-dose insulin with concomitant glucose infusion titrated to normoglycemia) versus standard therapy (insulin treatment if glucose >150 mg/dL). Our primary outcomes were left ventricular longitudinal strain and strain rate, assessed using speckle-tracking echocardiography. Right atrial tissue was analyzed for activation of glycolysis/pyruvate oxidation and alternative metabolic pathways. Results Time-weighted mean glucose concentrations were lower with HNC (127±19 mg/dL) than standard care (177±41 mg/dL; P<0.001). Echocardiographic data were adequate in 72 patients for strain analysis and 67 patients for strain rate analysis. HNC did not improve myocardial strain, with an HNC minus standard therapy difference of −1.2 (97.5%CI: −2.9, 0.5)%; P=0.11. Strain rate was significantly better, but by a clinically unimportant amount: −0.16 (−0.30, −0.03) sec−1, P = 0.007. There was no evidence of increased glycolytic, pyruvate oxidation, or hexosamine biosynthetic pathway activation in right atrial samples (n = 20, HNC; 22, standard therapy). Conclusions Administration of glucose and insulin while targeting normoglycemia during aortic valve replacement did not meaningfully improve myocardial function.
Background The immediate effect of aortic valve replacement (AVR) for aortic stenosis on perioperative myocardial function is unclear. Left ventricular (LV) function may be impaired by cardioplegia-induced myocardial arrest and ischemia-reperfusion injury, especially in patients with LV hypertrophy. Alternatively, LV function may improve when afterload is reduced following AVR. The right ventricle (RV), however, experiences cardioplegic arrest without benefiting from improved loading conditions. Which of these effects on myocardial function dominate in patients undergoing AVR for aortic stenosis has not been thoroughly explored. Our primary objective thus to characterize the effect of intraoperative events on LV function during AVR using echocardiographic measures of myocardial deformation. Secondarily, we evaluated RV function. Methods In this supplementary analysis of 100 patients enrolled in a clinical trial (NCT01187329), 97 patients underwent AVR for aortic stenosis. Of these patients, 95 had a standardized intraoperative transesophageal echocardiographic examination of systolic and diastolic function performed before surgical incision and repeated after chest closure. Echocardiographic images were analyzed off-line for global longitudinal myocardial strain and strain rate using 2-dimensional speckle-tracking echocardiography. Myocardial deformation assessed at the beginning of surgery was compared with the end of surgery using paired t-tests corrected for multiple comparisons. Results LV volumes and arterial blood pressure decreased, and heart rate increased at the end of surgery. Echocardiographic images were acceptable for analysis in 72 patients for LV strain, 67 for LV strain rate, and 54 for RV strain and strain rate. In 72 patients with LV strain images, 9 patients required epinephrine, 22 required norepinephrine, and 2 required both at the end of surgery. LV strain did not change at the end of surgery compared with the beginning of surgery [difference: 0.7 (97.6%CI: 0.2, 1.5)%; P =0.07] while LV systolic strain rate improved (became more negative) [−0.3 (−0.4, −0.2) sec−1; P<0.001]. In contrast, RV systolic strain worsened (became less negative) at the end of surgery [difference: 4.6 (3.1, 6.0)%; P< 0.001] although RV systolic strain rate was unchanged [0.0 (97.6% CI: −0.1, 0.1); P = 0.83]. Conclusion LV function improved after replacement of a stenotic aortic valve demonstrated by improved longitudinal strain rate. In contrast, RV function, assessed by longitudinal strain, was reduced.
OBJECTIVE Evaluations of stents by MDCT from studies performed at single centers have yielded variable results with a high proportion of unassessable stents. The purpose of this study was to evaluate the accuracy of 64-MDCT angiography (MDCTA) in identifying in-stent restenosis in a multicenter trial. MATERIALS AND METHODS The Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography Using 64 Detectors (CORE-64) Multicenter Trial and Registry evaluated the accuracy of 64-MDCTA in assessing 405 patients referred for coronary angiography. A total of 75 stents in 52 patients were assessed: 48 of 75 stents (64%) in 36 of 52 patients (69%) could be evaluated. The prevalence of in-stent restenosis by quantitative coronary angiography (QCA) in this subgroup was 23% (17/75). Eighty percent of the stents were ≤ 3.0 mm in diameter. RESULTS The overall sensitivity, specificity, positive predictive value, and negative predictive value to detect 50% in-stent stenosis visually using MDCT compared with QCA was 33.3%, 91.7%, 57.1%, and 80.5%, respectively, with an overall accuracy of 77.1% for the 48 assessable stents. The ability to evaluate stents on MDCTA varied by stent type: Thick-strut stents such as Bx Velocity were assessable in 50% of the cases; Cypher, 62.5% of the cases; and thinner-strut stents such as Taxus, 75% of the cases. We performed quantitative assessment of in-stent contrast attenuation in Hounsfield units and correlated that value with the quantitative percentage of stenosis by QCA. The correlation coefficient between the average attenuation decrease and ≥ 50% stenosis by QCA was 0.25 (p = 0.073). Quantitative assessment failed to improve the accuracy of MDCT over qualitative assessment. CONCLUSION The results of our study showed that 64-MDCT has poor ability to detect in-stent restenosis in small-diameter stents. Evaluability and negative predictive value were better in large-diameter stents. Thus, 64-MDCT may be appropriate for stent assessment in only selected patients.
OBJECTIVE The purpose of this article is to estimate the absorbed radiation dose in radiosensitive organs during coronary MDCT angiography using 320-MDCT and to determine the effects of tube voltage variation and heart rate (HR) control on absorbed radiation dose. MATERIALS AND METHODS Semiconductor field effect transistor detectors were used to measure absorbed radiation doses for the thyroid, midbreast, breast, and midlung in an anthropomorphic phantom at 100, 120, and 135 kVp at two different HRs of 60 and 75 beats per minute (bpm) with a scan field of view of 320 mm, 400 mA, 320 × 0.5 mm detectors, and 160 mm collimator width (160 mm range). The paired Student’s t test was used for data evaluation. RESULTS At 60 bpm, absorbed radiation doses for 100, 120, and 135 kVp were 13.41 ± 3.59, 21.7 ± 4.12, and 29.28 ± 5.17 mGy, respectively, for midbreast; 11.76 ± 0.58, 18.86 ± 1.06, and 24.82 ± 1.45 mGy, respectively, for breast; 12.19 ± 2.59, 19.09 ± 3.12, and 26.48 ± 5.0 mGy, respectively, for lung; and 0.37 ± 0.14, 0.69 ± 0.14, and 0.92 ± 0.2 mGy, respectively, for thyroid. Corresponding absorbed radiation doses for 75 bpm were 38.34 ± 2.02, 59.72 ± 3.13, and 77.8 ± 3.67 mGy for midbreast; 26.2 ± 1.74, 44 ± 1.11, and 52.84 ± 4.07 mGy for breast; 38.02 ± 1.58, 58.89 ± 1.68, and 78 ± 2.93 mGy for lung; and 0.79 ± 0.233, 1.04 ± 0.18, and 2.24 ± 0.52 mGy for thyroid. Absorbed radiation dose changes were significant for all organs for both tube voltage reductions as well as for HR control from 75 to 60 bpm at all tube voltage settings (p < 0.05). The absorbed radiation doses for the calcium score protocol were 11.2 ± 1.4 mGy for midbreast, 9.12 ± 0.48 mGy for breast, 10.36 ± 1.3 mGy for lung, and 0.4 ± 0.05 mGy for thyroid. CONCLUSION CT angiography with 320-MDCT scanners results in absorbed radiation doses in radiosensitive organs that compare favorably to those previously reported. Significant dose reductions can be achieved by tube voltage reductions and HR control.
Clinically significant improvements after IDB initially reported at 6 months were maintained at 9 and 12 months. The cross-over subjects had similar improvement in all outcome measures at all observed time points.
OBJECTIVE The purpose of this study was to evaluate the relation between radiation dose reduction and volume scan length for prospectively ECG-gated 320-MDCT angiography in the diagnosis of coronary artery disease. MATERIALS AND METHODS MDCT with prospective ECG gating was performed at one of the three volume scan lengths depending on heart length. Of 175 patients, 95 (55%; body mass index, 29 ± 5.9; mean heart rate, 59 ± 7 beats/min) underwent scanning at 160 mm; 46 (26%; body mass index, 30 ± 4.1; mean heart rate, 56 ± 5.74 beats/min) at 140 mm; and 34 (19%; body mass index, 30 ± 3.71; mean heart rate, 58 ± 3.96 beats/min) at 120 mm. RESULTS The median radiation doses were 6.5 mSv (95% CI, 6.03–7.2 mSv) for the 95 patients who underwent scanning at a volume scan length of 160 mm, 4.33 mSv (95% CI, 4.06–6.62 mSv) for the 46 patients who underwent scanning at 140 mm, and 3.47 mSv (95% CI, 3.15–3.62 mSv) for the 34 patients who underwent scanning at 120 mm. The reduction in scan length from 160 to 140 mm represented a reduction in scan length of 12.5% and the reduction to 120 mm a reduction of 25%. The median radiation dose was reduced 33% when volume scan length was changed to 140 mm and 47% when the length was changed to 120 mm. CONCLUSION Dose optimization remains an important concern in cardiac CT, and for 320-MDCT angiography, substantial dose reduction can be achieved by reducing volume scan length so that it is in concert with the patient’s heart length.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.